Summary
[edit | edit source]The power supply trouble shooting chart from Sharp's MZ-80A service manual (PDF page 23, printed page 20). It covers four faults: no output at all, no -5 V, no +12 V and no +5 V, with the AC and DC voltages to expect at the transformer windings and reservoir capacitors and the parts to check at each step. Rendered from File:Sharp MZ-80A Service Manual.pdf.
Source
[edit | edit source]Sharp Corporation, MZ-80A service manual (PDSM981010-MZ); scan from https://sharpmz.net/mz-80a/download/80asm.pdf, retrieved 2026-10-21.