Atari Falcon030 Reversed Capacitor Repair

Two electrolytic capacitors on the Atari Falcon030 main board are fitted the wrong way round at the factory, according to measurements by owners on exxos's forum. One is the coupling capacitor of the composite sync output, which exxos found with about 3.9 V across it in reverse; on his own Falcon, turning it round cured a monitor that lost sync every 30 seconds or so.[1] The other is C6, the reservoir capacitor of the negative supply for the serial port, which owners found with its positive end on the −12 V side.[2]
On Atari's schematic the composite sync line, CSYNC, is driven from transistor Q3 through C24 and R30, and C6 smooths the output of the charge pump on the serial port's TL497A regulator, U3.[3] Atari's parts list gives C24 as 470 µF 35 V and lists it only for the NTSC, PAL-I and PAL-B boards, which carry the video encoder; C6 is 4.7 µF 25 V on every board.[4]
Symptoms
[edit | edit source]- A monitor on the composite sync output loses sync at intervals, of about 30 seconds on exxos's Falcon.[1]
- A new capacitor fitted in the composite sync position the same way as the original bulges within days.[1]
- C6 has no reported symptom; owners found it by measurement.[2]
See also the Atari Falcon Troubleshooting Guide.
Safety
[edit | edit source]The Falcon's power supply runs from the mains. Unplug the machine before taking it apart, and switch off and unplug it again before each soldering step. The measurements below are made with the board running: keep probes and tools clear of the supply. Atari recommends retesting the computer once it is back in its case, to make sure nothing shorts to the shield.[4]
Tools and parts
[edit | edit source]- A screwdriver for the case, shield and board screws.[4]
- A multimeter.
- A soldering iron and desoldering tool.
- Replacements, if the old parts are not to be reused: 470 µF 35 V axial for C24, and 4.7 µF 25 V axial for C6, the values in Atari's parts list.[4]
| Part | Value (Atari) | Boards | Circuit | Reported fault |
|---|---|---|---|---|
| C24 | 470 µF 35 V | NTSC, PAL-I, PAL-B | Composite sync coupling, from Q3 to CSYNC | About 3.9 V reversed across it |
| C6 | 4.7 µF 25 V | All | −12 V reservoir after the charge pump of U3 | Positive end on −12 V |
Sources: Atari's parts list and schematic,[4][3] and the two forum threads.[1][2]
Procedure
[edit | edit source]Expose the main board
[edit | edit source]Atari's sequence:[4]
- Unplug the machine and turn it upside down.
- Remove the four screws in the square holes and the three screws in the round holes.
- Turn the unit upright and lift off the top case.
- Unplug the keyboard harness at the right front corner and remove the keyboard.
- Remove the nine screws holding the shield and speaker assembly, and remove the shield.
- Turn the unit upside down and remove the three screws in the round holes that hold the floppy drive.
- Holding the drive in place, turn the unit back over.
- Lift the drive slightly, unplug its power harness and ribbon cable, and remove the drive and its standoffs.
- Unplug the power supply's harness at its right front corner, remove the four screws at its corners and lift it out.
- Lift out the memory board.
- Remove the three screws at the front of the shield and board assembly, lift it at the front and pull it forward.
- Remove the six screws of the upper shield and lift the shield off.
Atari notes that the board in this state is convenient for troubleshooting, with the keyboard and drive reconnected beside it if needed.[4] For the measurements below the supply's harness has to be plugged back into the board.
Check C24
[edit | edit source]C24 is fitted only on boards with the video encoder.[4]
- Switch on and measure the DC voltage across C24, with the red probe on the end marked + on the capacitor.[1]
- A negative reading means C24 is reversed: exxos read −3.89 V.[1]
- Switch off and unplug the supply's harness.
- Desolder C24.
- Refit it, or a new 470 µF 35 V part, turned round, so that + goes to the pad that measured more positive.[1][4]
- Switch on and measure again. The reading should now be positive; exxos read 3.49 V.[1]
Check C6
[edit | edit source]
- Switch on and measure the voltage from each leg of C6 to ground. Owners found −12 V on the leg nearest the edge of the case and 0 V on the inner leg.[2]
- Note which end of the capacitor is marked +. If + is on the −12 V leg, the capacitor is reversed; owners found it fitted that way to match the board's + marking.[2]
- Switch off and unplug the supply's harness.
- Desolder C6.
- Refit it, or a new 4.7 µF 25 V part, with − on the −12 V leg and + on the grounded leg.[2][4]
- Switch on and measure again: −12 V on the − end, 0 V on the + end.[2]
Reassemble
[edit | edit source]Atari's sequence:[4]
- Fit the insulation panel on the bottom shield, the main board on top of it, and the upper shield with its six screws.
- Put the assembly in the lower case and refit the three screws at the front.
- Refit the memory board.
- Refit the power supply with its four corner screws and plug its harness into the main board.
- Refit the floppy drive and its standoffs, lift it slightly and plug in its power harness and ribbon cable.
- Holding the drive in place, turn the unit over, refit the three screws in the round holes and turn it back.
- Refit the shield and speaker assembly with its nine screws.
- Refit the keyboard and plug its harness in at the right front corner.
- Refit the top case with the four screws in the square holes and the three in the round holes.
Testing
[edit | edit source]- Run the Falcon on a monitor that uses composite sync and watch for loss of sync over a long session; exxos watched for two hours.[1]
- Check C24 a few days later for bulging.[1]
- Run the serial port test on Atari's diagnostic cartridge, if available, to check the port that uses the −12 V supply.[4]
Related pages
[edit | edit source]- Atari Falcon030
- Atari Falcon Capacitor Replacement Guide
- Atari Falcon Troubleshooting Guide
- Atari Falcon General Maintenance
- Atari Falcon030 Schematic
- Atari Falcon030 Service Guide
References
[edit | edit source]- ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 exxos and others, "Falcon Csync video fault", exxosforum.co.uk, from 20 March 2019: the composite sync coupling capacitor measured at −3.89 V, and 3.49 V after it was turned round; a replacement fitted the original way bulged after three days; sync lost about every 30 seconds before, none in two hours after; CSYNC driven through that capacitor from the buffer transistor Q3, which buffers pin 9 of the MC1377.
- ↑ 2.0 2.1 2.2 2.3 2.4 2.5 2.6 Steve, T'PAU, exxos, mikro and others, "Falcon cap C6 incorrect polarity?", exxosforum.co.uk, from 27 November 2022: a meter reading of −12 V on C6; the leg nearest the edge of the case is not grounded and is marked + on the silkscreen, the inner leg is grounded; ground is the more positive side, so the capacitor's negative leg belongs on the −12 V side.
- ↑ 3.0 3.1 Atari Microsystems Corporation, FALCON 030 main board schematic, revision A, 28 May 1992: PDF page 3, the video encoder U18 (MC1377), Q3 (2N3904), C24 (470 µF), R30 (75 Ω) and the CSYNC line, with the separate CSYNC drive through Q1 and R31 for non-modulator systems; PDF page 9, the TL497A U3, L45, R8, the charge pump C2, D3 and D2, and C6 (4.7 µF) with C22. Hosted here: Atari Falcon030 Schematic (PDF).
- ↑ 4.00 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 Atari Corporation, Atari Falcon030 Service Guide, C303062-001, 1 October 1992. Section 4, disassembly and reassembly (printed pp. 99–101, PDF pp. 105–107); section 7, parts list: main board variants and the parts unique to each (printed pp. 111–115), parts common to all boards (printed pp. 115–126). Hosted here: Atari Falcon030 Service Guide (PDF).