Jump to content

Atari 1040STE Reset Circuit Repair

From RetroTechCollection
Atari 1040STE
An Atari 1040STE. The 520STE uses the same main board and reset circuit.

The Atari 1040STE holds its 68000 in reset for a moment after it is switched on, using a single 555 timer, U104, which the reset button S100 on the back panel also triggers. The Atari 520STE uses the same main board with half the RAM.[1][2]

On many STEs now the machine does not start properly at switch-on and needs the reset button pressed. exxos lists the repair among the fixes every ST-family machine needs, blaming the circuit's design and capacitors that have aged for thirty years, and documented the STE fix on his forum: more capacitance at C100 and a new C102.[3][4]

Symptoms

[edit | edit source]
  • After switch-on the screen stays blank or garbled, or the machine does nothing, until the reset button is pressed; then it starts normally.[4]
  • exxos saw it on a stock machine while testing SIMMs, and reports it also appears after fitting accelerators or changing the power supply.[4]

Rule out the power supply before the reset circuit: an STE that fails to start can also have a failing supply or unsuitable SIMMs.[3] See the Atari STE Troubleshooting Guide.

How the circuit works

[edit | edit source]
Atari STE reset circuit (schematic C300780-001 sheet 1)
The STE reset circuit on Atari's schematic: the reset button S100, C100, R100 and D100 on the trigger input of U104, the timing parts R101 and C102, and C101 on the control-voltage pin. The power connector J100 and its reservoir C103 are at the right.
Reset parts on the STE (schematic and parts list)
Part Value Connection
U104 555 timer Reset timer
C100 10 µF 35 V, radial Trigger input (pin 2), to ground
R100 10 kΩ Trigger input to VCC
D100 1N914 Trigger input to VCC
S100 Reset button Trigger input to ground
R101 12 kΩ VCC to the threshold and discharge pins (6 and 7)
C102 22 µF 16 V, axial Threshold and discharge pins to ground
C101 0.01 µF Control voltage (pin 5)

Sources: the schematic[1] and Atari's parts list.[2]

At switch-on C100 is discharged, so it holds the trigger input low and starts the timer; it then charges through R100. Pressing S100 pulls the same input to ground. Once started, the timer's output on pin 3 holds the reset line for a time set by R101 and C102.[1] exxos's simulations showed that with C100 missing the circuit gives no reset at all, and that a slowly rising +5 V supply can defeat it with the original values; raising C100 is what fixed real machines, though in simulation it made little difference to the reset time, which C102 sets.[4]

Tools and parts

[edit | edit source]
  • A 47 µF electrolytic for C100 and a new 22 µF for C102. exxos gives 10–63 V as typical ratings; Atari's originals are 35 V and 16 V.[4][2]
  • Soldering iron and desoldering tool.

Procedure

[edit | edit source]

Open the machine

[edit | edit source]

Atari's sequence for the STE:[2]

  1. Unplug the machine. Turn it upside down and remove the six screws in the square holes and the three in the round holes, which hold the disk drive.
  2. Turn it upright, lift off the top case and unplug the keyboard harness at the right front corner.
  3. Lift the drive slightly and unplug its power harness and ribbon cable.
  4. Remove the screw on the right side of the power supply shield and the three screws between the back-panel shield and the power supply shield, straighten the two twist tabs and lift the supply shield off from the rear.
  5. Remove the two screws at the front corners of the power supply (or remove the supply: unplug its harness at its right front corner and lift it out).
  6. Remove the three screws at the front of the shield and board assembly, lift it at the front and pull it forward.
  7. Straighten the twist tabs on the upper shield (usually four), remove any copper tape and lift the shield straight up.

Replace the capacitors

[edit | edit source]
  1. Find U104, C100 and C102 on the board, using the schematic crop above to confirm them by their connections to the 555.[1]
  2. Note the polarity of C100 and C102.
  3. Replace C100 with a 47 µF capacitor, observing polarity.[4]
  4. Replace C102 with a new 22 µF capacitor, observing polarity.[4]

exxos's first, quick version of the fix was to solder a 22 µF capacitor across the existing C100, giving about 33 µF, without removing anything; others confirmed that it worked.[4]

Reassemble

[edit | edit source]

Atari's reassembly order: insulation panel and main board on the bottom shield, the power supply connector and supply, the top shield with its tabs twisted, the assembly into the case, the supply's two front screws, the supply shield and its screws, the drive cables, the front screws of the main assembly, the keyboard harness, the top cover and the case screws, the three longer ones in the round holes.[2]

Testing

[edit | edit source]
  • Switch the machine off and on several times, cold and warm. It should start each time without the reset button.[3]
  • Press the reset button with the machine running; it should restart.
  • With an oscilloscope, U104's output on pin 3 should pulse at switch-on and whenever S100 is pressed.[1]
[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.0 1.1 1.2 1.3 1.4 Atari Corporation, STe schematic, drawing C300780-001, revision A, 3 October 1989, sheet 1: U104 (LM555), C100, C101, C102, R100, R101, D100, the reset switch S100 and the power connector J100. Hosted here: File:Atari STE Schematic Rev A C300780-001.pdf.
  2. ↑ 2.0 2.1 2.2 2.3 2.4 Atari Corporation, 520STE/1040STE Field Service Manual. Disassembly and reassembly (section 4, printed pp. 43–44, PDF pp. 48–49); parts list: U104 555 timer, C100 10 µF 35 V radial, C102 22 µF 16 V axial (printed p. 53, PDF p. 58). Hosted here: Atari 520STE/1040STE Field Service Manual (PDF).
  3. ↑ 3.0 3.1 3.2 exxos, "MANDATORY FIXES", exxos's Atari, Amiga & retro forum, 31 January 2019, item 11, the reset fix for ST, STF, STM, STE and Mega ST machines.
  4. ↑ 4.0 4.1 4.2 4.3 4.4 4.5 4.6 4.7 exxos, "STE no reset on power up issue fix", exxos's Atari, Amiga & retro forum, 2019 onwards: the symptom, the quick fix of a 22 µF capacitor across C100, the recommended replacement of C100 with 47 µF and C102 with a new 22 µF (10–63 V), his circuit simulations, and the remark that the reset circuits of the STFM, Falcon and Mega are similar.