Atari 520ST Reset Circuit Repair

When the Atari 520ST is switched on, a timer holds the 68000 processor in reset for a moment while the supply settles, then lets it start; the reset button on the back panel triggers a second timer that does the same. Both timers are in one 556 dual timer, U37, on the main board.[1] The same circuit is on the 260ST, which shares the schematic, and on the 520ST+ and 520STM, which share the short-case board.[2]
The common fault on ST machines now is a machine that does not start properly when switched on but runs after the reset button is pressed. exxos lists it among the fixes every ST needs, blaming a weak design and capacitors that have aged for over thirty years.[3]
Symptoms
[edit | edit source]- The machine powers up to a blank or garbled screen, or does nothing, until the reset button is pressed; after that it starts normally.[3]
- The reset button does nothing, though the machine starts correctly at power-up.[4]
- A dead machine with the processor halted. Atari's dead-unit procedure checks pin 17 (HALT) of the 68000, which should be at a TTL high; if it is low, one of the causes is a bad reset circuit.[5]
A machine that will not start for other reasons, such as a weak supply, a missing clock or a failed chip, can look the same. Check the +5 V rail first (see Atari 520ST Power Supply Repair) and use the Atari ST Troubleshooting Guide if the reset line behaves correctly.
How the circuit works
[edit | edit source]
| Half | Starts on | Timing parts | Other parts | Output |
|---|---|---|---|---|
| Power-on | Switching on: C50 charges through R83 | R83 12 kΩ, C50 22 µF | C48 0.01 µF on the control-voltage pin | Pin 9 (OUT2) |
| Reset button | Pressing SW2, which pulls the trigger input low | R82 12 kΩ, C55 22 µF | R93 10 kΩ pull-up and C70 0.1 µF on the trigger; C49 0.01 µF on the control-voltage pin | Pin 5 (OUT1) |
Source: the schematic.[1] The timer outputs drive open-collector 74LS05 inverters in U36, whose outputs hold the 68000's RESET (pin 18, pulled up by R31) and HALT (pin 17, pulled up by R75) lines low while a timer runs.[1] The power-on time constant, R83 × C50, is 12 kΩ × 22 µF, about a quarter of a second; when C50 has lost capacitance the reset pulse at switch-on becomes shorter.[1]
SAMS splits the faults the same way: a wrong power-on reset points at U36, U37, C48, C50 and R83; a reset button that does nothing points at SW2, U36, U37, R82, R93, C55 and C70.[4]
Tools and parts
[edit | edit source]- An oscilloscope or logic probe for pin 18 of the 68000.[4]
- Two 22 µF electrolytic capacitors for C50 and C55, the values on Atari's schematic. Read the voltage rating from the old parts.[1]
- If the timer itself is suspect, a 556 for U37 and a 74LS05 for U36.[1]
Procedure
[edit | edit source]Open the machine
[edit | edit source]Atari's sequence for the short case:[5]
- Unplug the supply. Turn the computer over and remove the six screws from the bottom case.
- Turn it upright, lift off the top case and unplug the keyboard at the right front of the board.
- Remove the three screws at the front edge of the board and the three at the rear, reached through holes in the shield, and lift the board assembly out.
- Straighten the ten twist tabs and lift off the top shield. Reconnect the keyboard, supply and monitor to work on the board.
Check the reset line
[edit | edit source]- Connect the logic probe or oscilloscope to pin 18 of the 68000 (U10).[4]
- Switch on. Pin 18 should be low as the machine powers up and then go high immediately afterwards.[4]
- Press the reset button. Pin 18 should go low while it acts and then return high.[4]
- Check pin 17 (HALT) the same way; Atari expects it at a TTL high once the machine is running.[5]
Repair a failed power-on reset
[edit | edit source]- Replace C50 (22 µF), the power-on timing capacitor. Check its polarity against the board before removing it.[1][4]
- Check R83 (12 kΩ) and C48 (0.01 µF).[4]
- If the fault remains, check U37's output on pin 9 and the U36 inverters it drives; replace U37 or U36 as the waveforms show.[4][1]
On the STE, which has the same kind of circuit with different values, exxos and others cured the fault by adding capacitance to the timer's capacitor, and he suggests renewing both reset capacitors; he notes that the reset circuits of the STFM, Falcon and Mega are similar.[6] The 520ST's two timing capacitors are both 22 µF on Atari's schematic.[1]
Repair a reset button that does nothing
[edit | edit source]- Check SW2 for continuity when pressed.[4]
- Check R93 (10 kΩ), C70 (0.1 µF), R82 (12 kΩ) and C55 (22 µF); replace C55.[4][1]
- Check U37's output on pin 5 and the U36 inverters it drives.[4][1]
Reassemble
[edit | edit source]Refit the top shield, twist the tabs, refit the board and its six screws, the keyboard connector and the top case, with the longer case screws at the rear.[5]
Testing
[edit | edit source]- Switch the machine off and on several times, with the supply cold and after it has warmed up. It should start every time without the reset button.[3]
- Press the reset button with the machine running; it should restart.[4]
- Watch pin 18 of the 68000 at power-up: low, then high.[4]
Related pages
[edit | edit source]- Atari 520ST, Atari 260ST, Atari 520ST+ and Atari 520STM
- Atari 520ST Power Supply Repair
- Atari ST Capacitor Replacement Guide
- Atari ST Troubleshooting Guide
- Atari 520ST Schematic (C070231)
References
[edit | edit source]- ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 Atari (Japan) Corporation, Schematic Diagram (520ST/260ST), drawing C070231, revision M (April 1986), sheet 2: U37 (556), SW2, R82, R83, R93, C48, C49, C50, C55 and C70; the 74LS05 inverters U36; the 68000 U10 with RESET on pin 18 (pull-up R31, 1 kΩ) and HALT on pin 17 (pull-up R75). Hosted here: File:Atari 520ST Schematic C070231.pdf.
- ↑ "Atari 520ST, 260ST, 520ST+, 520STM, 130ST und ST Junior", atari-computermuseum.de (in German), revised 26 June 2024: the short-case models and their common main board, C070243.
- ↑ 3.0 3.1 3.2 exxos, "MANDATORY FIXES", exxos's Atari, Amiga & retro forum, 31 January 2019, item 11, "ST/F/M/E /MEGA ST – Reset fix": machines fail to reset on power-up and need the reset button pressed, because of the circuit's design and old capacitors.
- ↑ 4.00 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 SAMS Computerfacts CSCS12: Atari Model 520ST, Howard W. Sams & Co., June 1986, ISBN 0-672-08974-2. Troubleshooting, "Microprocessor operation": the behaviour of pin 18 of U10 at power-up and when SW2 is pressed, and the parts to check for each fault (printed p. 26, PDF p. 28). Internet Archive.
- ↑ 5.0 5.1 5.2 5.3 Atari Corporation, 520ST/1040ST Computer Field Service Manual, C026118-002 Rev B (3.6), January 1987. "Troubleshooting a dead unit", HALT and the reset circuit (PDF pp. 29–30); 520ST disassembly (pp. 4.3–4.4, PDF pp. 48–49). Hosted here: File:Atari 520ST and 1040ST Computer Field Service Manual.pdf.
- ↑ exxos, "STE no reset on power up issue fix", exxos's Atari, Amiga & retro forum, 2019 onwards: the STE fix on C100 and C102, the advice to replace both capacitors, the remark that the reset circuits of other ST models are similar, and his later reply naming C2 and C7 on a C070789 Rev D STFM board.