Atari 400 Power Supply Repair

The Atari 400 makes its own supply rails. The external adaptor is a transformer that supplies 9 V AC; a power supply board inside the console, which also carries the RF modulator and the peripheral (SIO) socket, rectifies it and produces +5 V, +12 V and −5 V for the rest of the machine.[1] The power switch S203 and an interlock switch S202, which breaks the supply when the top panel is opened to change a cartridge, are both in the AC input.[1] Howard W. Sams's Computerfacts for the 400 gives a voltage at each stage of the board, which makes the fault easy to locate.[2]
Symptoms
[edit | edit source]- The power LED (CR210) does not light.[2]
- A snowy screen with no Memo Pad. Atari's chart checks for +5 V at J201 pins 5, 6 and 7 first.[1]
- A black or grey screen. Atari's chart checks for −5 V at J201 pin 18 and +12 V at J201 pin 2.[1]
Safety
[edit | edit source]- The adaptor plugs into the mains. Measure it only at its output plug.
- Let the large reservoir capacitors discharge after switch-off before handling the board.
- Unplug the adaptor before removing or refitting the power supply board.
Tools and parts
[edit | edit source]- A multimeter with AC and DC voltage ranges, and continuity.
- A cross-head screwdriver.
- A known-good adaptor. The FAQ lists Atari's 9 V AC adaptors for the 400 as the 15.3 VA C014319, which it calls "only barely adequate" for the 400, 800 and 1200XL, and the 31 VA C017945.[3]
- Parts from Atari's parts list as needed:[1]
| Position | Part | Atari number |
|---|---|---|
| A202 | Voltage regulator, 5 V (drawn as 7805) | C014348 |
| A201 | Voltage regulator, 12 V (drawn as 78M12) | C014349 |
| CR206–CR209 | Bridge diodes, 1N5391 | C017988 |
| CR201 | Zener diode 1N5231B, 5.1 V | C014808-01 |
| C209 | 4700 µF 16 V radial | C014374-01 or -02 |
| C204, C205 | 2200 µF 16 V axial | C014373 |
| C201, C202 | 470 µF 16 V axial | C014370 |
| R202 | 33 Ω (2 W on the schematic) | C014771 |
| S202 | Power interlock switch | C014387 |
| S203 | Power switch | C014397-01 |
| J204 | Power jack | C014715 |
Procedure
[edit | edit source]Check the adaptor
[edit | edit source]- Plug the adaptor into the mains and unplug its lead from the computer. Measure across the plug on the AC range: Sams gives 10.42 V AC.[2] Atari rates the adaptor at 9 V AC.[1]
- If the voltage is wrong or missing, replace the adaptor.[2]
Remove the power supply board
[edit | edit source]
- Turn the unit upside down and remove the four screws from the bottom cover.[1]
- Turn the unit upright, unhook the top cover from the keyboard, open the cartridge door and lift the top cover off.[1]
- Remove the single keyboard screw, lift the left end of the keyboard and disconnect the keyboard ribbon cable.[1]
- Disconnect the RF cable from the power supply and remove the two power supply screws.[1]
- Pull the power supply gently away from the casting by about a quarter of an inch and lift out the interlock switch plunger.[1]
- Lift the power supply straight up off the motherboard connector pins.[1]
Sams's checks below are made with the adaptor connected and the power switched on.[2]
Measure the supply stage by stage
[edit | edit source]
Work through Sams's checks in order. Each row gives the voltage, where to measure it and the parts Sams names if it is missing; Sams also says to check for shorts to ground at each stage.[2]
| Stage | Measure | Expected | If missing, check |
|---|---|---|---|
| AC input | Cathode of CR207 to cathode of CR209 | 10.42 V AC | Interlock switch S202, power switch S203, C211, ferrite bead L204, jack J204, adaptor |
| Rectified DC | Input of A202 (Sams: pin 1) | 11.84 V | CR206–CR209, C208, C209 |
| +5 V | Output of A202 (Sams: pin 3) | 5.08 V | A202 |
| Doubled DC | Input of A201 (Sams: pin 1) | 23.7 V | CR204, CR205, C203, C204, C205 |
| +12 V | Output of A201 (Sams: pin 3) | 12.25 V | A201 |
| Negative DC | Anode of CR202 | −11.85 V | CR202, CR203, C201, C202 |
| −5 V | Anode of zener CR201 | −5.01 V | CR201, power LED CR210, R201 |
Sams numbers the regulator pins input 1 and output 3. Atari's schematic draws the same parts with the input marked 3 and the output marked 1, so identify each pin by what it connects to.[2][1]
Follow Atari's flowcharts
[edit | edit source]- With +5 V missing at J201 pins 5, 6 and 7, Atari's chart says to check, repair or replace the bridge diodes CR206 to CR209, replacing 1N4001-type diodes there with 1N5391 (C017988); to check that the regulator A202 has +5 V; and to check C208, C209, R203 and S202.[1]
- With −5 V missing at J201 pin 18, the chart names CR206 to CR209 (again replacing 1N4001 types with 1N5391), CR201 to CR203, C201, C202 and C210.[1]
- With +12 V missing at J201 pin 2, it names the regulator A201, CR204 and C203 to C205.[1]
The chart's R203 is the 6.8 kΩ resistor at the RF modulator on the May 1983 schematic, where the 33 Ω 2 W resistor across A202 is R202; check both.[1]
Refit the board
[edit | edit source]- Align the power supply over the motherboard connector pins and the bottom cover guide posts and press it gently down.[1]
- Fit the interlock switch plunger into the aluminium casting, with its lower end over the interlock switch and its shaft riding in its notch in the power supply heat sink.[1]
- Refit the two power supply screws. Route the RF cable through its slot in the power supply board, without trapping it under the module assembly, and plug it into the power supply jack.[1]
- Reconnect the keyboard ribbon cable, lower the keyboard over the power-on LED and guide posts, and refit the keyboard screw.[1]
- Open the cartridge door, slide the top cover down over it and the power-on LED, guide its locator pins into the keyboard holes and snap its hood under the keyboard. Close the door, set the console on its face and refit the four bottom screws.[1]
Testing
[edit | edit source]- Switch on with no cartridge. The power LED should light and the ATARI COMPUTER - MEMO PAD screen should appear.[2][1]
- Measure the rails at the motherboard connector J201: +5 V at pins 5 and 6 (+5 V A) and pin 7 (+5 V B), +12 V at pin 2 and −5 V at pin 18.[1]
- Open and close the cartridge door to check that the interlock switches the machine off and on.[1]
Related pages
[edit | edit source]- Atari 400
- Atari 400 Troubleshooting Guide
- Atari 400 General Maintenance
- Atari 400 Capacitor Replacement Guide
- Atari 800 Power Supply Repair
- Atari 400 800 Field Service Manual June 82
References
[edit | edit source]- ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.20 1.21 1.22 1.23 1.24 Atari, Inc., ATARI Home Computer Field Service Manual 400/800, May 1983 revision: power supply description (pp. 1-6 and 1-16), 400 power supply silkscreen and schematic (figures 2-3 and 2-4, pp. 2-7 and 2-8), 400 disassembly and assembly (section 4, pp. 4-1 to 4-5 and 4-15 to 4-16), 400 flowcharts AA and BB (pp. 5-3 and 5-4), 400 parts list (power supply assembly CA014155). Scan on the Internet Archive. The June 1982 edition is hosted here as Atari 400 800 Field Service Manual June 82.
- ↑ 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 Howard W. Sams & Co., Computerfacts CC5, Atari Model 400, 1984: "Power Supply Check" (service checks) and "Power Supply" (troubleshooting guide). Scan on the Internet Archive.
- ↑ Michael Current (ed.), Atari 8-Bit Computers: Frequently Asked Questions, last modified 29 November 2009, section 6.7, "What are the power requirements for my Atari components?". Text at faqs.org. Community reference.