The BBC Master 128 keeps its configuration (filing system, language, screen mode and other settings) and its real-time clock in a 146818 clock and CMOS RAM chip, IC11, which runs from a battery when the mains is off.[1] The same board, and so the same circuit, is in the Acorn Master Turbo, BBC Master 512 and BBC Master ET.[2] The usual failure is the battery pack, which goes flat and then leaks;[3][4] behind it are the plug PL8, a FET that connects the battery, and a power-down circuit that Acorn modified on early machines. Routine replacement of the pack is described in the maintenance guide; the BBC Master AIV keeps three cells in a nest under the case instead, as described on its own page.

Symptoms

[edit | edit source]
Battery backup faults
Symptom Where to look
Settings lost and the clock wrong after every power-off Flat battery, or PL8 not making contact on all three pins[5]
"This is not a language" and a * prompt at switch-on, returning after reconfiguring Battery pack[6]
CTRL BREAK behaves like BREAK The power-down parts round IC11: C11, D8 and Q3[7]
Starts in terminal mode and *CONFIGURE will not change it Same checks, then the connections to IC11[7]
Configuration lost at power-off with a good battery Acorn's power-down modification not fitted[8]
Clock does not count at all The 32.768 kHz oscillator, not the battery[9]

Other start-up faults are in the BBC Master 128 Troubleshooting Guide.

Safety

[edit | edit source]

Unplug the mains before opening the case. Acorn's battery leaflet says its warnings on handling and disposing of lithium cells apply to the 4.5 V pack too.[3] Leaked alkaline electrolyte is caustic; see Battery Explosion, Capacitor or Corrosion Damage for handling and neutralising it.

Tools and parts

[edit | edit source]
  • A multimeter. See Recommended Tools.
  • A replacement pack: three AA alkaline cells in a holder, with a 1N4001 (or higher-voltage 1N400x) diode and a 120 Ω ¼ W resistor in its lead; 1024MAK on stardot gives these as Acorn's parts and says the resistor value is not critical up to about 330 Ω.[10] RetroClinic sells ready-made packs and explains that the board charges whatever battery is fitted, which is why the diode is needed.[4]
  • A three-way 0.1-inch Molex KK housing and crimp terminals if the plug has corroded.[11] See Connector Pin Replacement and Crimping.
  • For Acorn's power-down change: a 100 µF capacitor for C11, a 1N4001 for D8 and a 1.8 kΩ resistor.[8]

Procedure

[edit | edit source]

Save the settings and open the case

[edit | edit source]
  1. Save the configuration if the machine still holds it: select a filing system, then type MODE 0, *SPOOL CONFIG, *STATUS and *SPOOL.[3]
  2. Disconnect the mains and all peripherals, turn the computer upside down and remove the four screws marked FIX, two at the front and two at the rear. The rear screws are longer.[3]
  3. Holding the two halves together, turn the computer back over and lift the top straight off.[3]

Remove the pack and check PL8

[edit | edit source]
  1. Find the pack. A new-style unit, three shrink-wrapped cells, is pushed into the recess west of the keyboard; an old-style unit is a holder on a metal plate between the west edge of the main board and the power supply, held by two screws.[3]
  2. Unplug its lead from PL8, on the west edge of the main board, noting how the lead is routed, and lift the pack out.[3]
  3. Look at the plug, the lead and the board round PL8. Green deposits on the plug contacts mean electrolyte has travelled up the wire inside its insulation; replace the lead and the plug with the cells.[11][10][4] Corrosion also reaches the solder pads near the plug, and one repairer reflows the resistors next to it.[11]
  4. Clean and neutralise any residue on the board and check the tracks from PL8 for continuity; PCB Trace Repair covers rebuilding an eaten track.
BBC Master 128 battery backup circuit (drawing 0143,000 sheet 2)
The battery backup circuit on Acorn's Master 128 circuit diagram (drawing 0143,000/C, sheet 2). PL8's centre pin feeds the battery-backed supply to the clock chip IC11 (Vcc, pin 24) and C11; its two outer pins are joined and return through R154 (470 Ω) and the FET Q4 (J177), whose gate is held by R155 (1 MΩ). D8 feeds the same supply from the computer's +5 V. Q3 with R23 and R29 inverts the chip select into IC11 pin 13. The charging parts Q2, R12, R15, R16, D5 and D6 are marked N/F, not fitted

Fit the new pack

[edit | edit source]
  1. Wire a home-made pack with its diode and resistor in the lead. Acorn's 1987 leaflet connects the black lead to the north pin of PL8 and the red lead to the centre pin, with the south pin unused.[12][10] On Acorn's circuit diagram the two outer pins are joined, which is why the 1993 leaflet says the plug fits either way round.[13][3]
  2. Push the plug over all three pins of PL8.[3]
  3. Mount the pack where a future leak cannot run onto the board. Acorn's new-style unit sits in the recess west of the keyboard, pushed down until its base is flush with the bottom of the case, with its lead routed east between the keyboard and the power supply, across the south end of the clear area and north along the west edge of the board to PL8.[3]

Check the backup circuit

[edit | edit source]
  1. With the mains off and the new pack fitted, measure the supply at the clock chip IC11. Acorn expects at least 2.6 V.[5]
  2. If it is low with a good pack, trace it on the diagram: the centre pin of PL8 to IC11 pin 24 and C11, and the outer pins through R154 and Q4 to 0 V.[13] Acorn names Q4 and the parts round it as the next check.[5] See Testing Diodes, Transistors and Regulators.
  3. If settings are lost at power-off although the battery holds its voltage, or CTRL BREAK acts as plain BREAK, check IC11's control lines with the machine idle: CE (pin 13) high with occasional low pulses, AS (pin 14) low and DS (pin 17) low.[7]
  4. On early machines, make Acorn's change: replace C11 with 100 µF (Acorn part 0610,100), replace D8 with a 1N4001 (0794,001), and fit a 1.8 kΩ resistor (0502,182) between the base and emitter of Q3 on the solder side of the board.[8][7] C11 is a 10 µF tantalum as built; fit the new part with the same polarity.[13][14]

Reassemble and restore the settings

[edit | edit source]
  1. Refit the top half; the longer screws go at the rear.[3]
  2. Connect the mains and switch on while holding R until a message appears, which resets the CMOS RAM.[3][15]
  3. Re-enter the settings with *CONFIGURE, using the saved *STATUS list, and set the time.[3]

Testing

[edit | edit source]
  • Leave the computer unplugged overnight. The settings and the time should survive, and *STATUS should match what was configured.[5]
  • CTRL BREAK resets to the configured settings; plain BREAK does not.[7]
[edit | edit source]

References

[edit | edit source]
  1. ↑ Acorn Computers, Master Series Microcomputer Service Manual, part no. 0443,004, issue 1, April 1986, "Real time clock with RAM", pp. 21–22: a 146818 RTC and RAM chip with battery-backed supply; a lithium manganese dioxide cell as built; a 10 µF capacitor across the clock chip supply to hold the data if the battery is disconnected; fifty bytes of CMOS RAM, twenty used for configuration; 32.768 kHz crystal with a trimming capacitor; the chip select is inverted by a transistor whose collector resistor runs from the battery-backed supply, so that the chip is deselected as the main supply fails.
  2. ↑ BBC Master 128 Troubleshooting Guide: the Master 128 board is shared by the Master Turbo, Master 512, Master AIV and Master ET.
  3. ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 Acorn Computers, Master Series Battery Unit, part no. 0443,900, issue 3, May 1993, hosted as File:Acorn BBC Master Series Battery Unit 0443,900 Issue 3.pdf: 4.5 V battery unit in place of the 3.0 V lithium cell, with the lithium handling and disposal warnings applying; life about one year, replace at least every 18 months to avoid leakage damage; saving the settings with *SPOOL CONFIG and *STATUS; compass directions with the keyboard facing you (south nearest, north at the rear, west on the left); four screws marked FIX underneath, the rear ones longer; new-style unit of three shrink-wrapped cells pushed into the recess west of the keyboard, old-style holder on a metal plate between the west edge of the main board and the power supply, held by two screws; lead routed to PL8 on the west edge of the board; the plug fits either way round but must cover all three pins; power-on reset with R held until a message appears.
  4. ↑ 4.0 4.1 4.2 RetroClinic, "BBC Master 128 – Replacement CMOS battery packs" (retrieved 2026-10-02). Vendor source: alkaline packs leak, mostly over the case and sometimes onto the board; alkali creeps up the cable to the board connector, so a leaking holder should be replaced with its cable; the Master board charges any battery connected, so packs carry a diode and current-limiting resistor; a three-AA alkaline pack or a single 3.7 V lithium thionyl chloride cell.
  5. ↑ 5.0 5.1 5.2 5.3 Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, 7.4.3 "Loses a lot of time", p. 40: check that PL8 is fitted with all three pins engaged and that the battery leads are soldered to the clips; replace a flat battery in its holder next to the speaker with the same polarity; there should be at least 2.6 V at the clock chip with the mains off, and if not, check the FET Q4 and the parts around it.
  6. ↑ Sprow, "The most common beeb power on problems", Sprow's webpages, updated 9 November 2010 (retrieved 2026-10-25). Master: "This is not a language" cured by *CONFIGURE LANG 12 and *INSERT 12, with the battery pack replaced if it recurs at the next switch-on; garbled time from a flat battery. Community source.
  7. ↑ 7.0 7.1 7.2 7.3 7.4 Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, 7.1.9 and 7.1.10, p. 35: when CTRL BREAK behaves as BREAK, check the power-down components round IC11; on some early computers C11 must be 100 µF instead of 10 µF, D8 a 1N4001, and Q3 needs a 1k8 resistor between base and emitter; IC11 chip enable (pin 13) normally high with occasional low pulses, from the system VIA IC8 pin 16; when not being accessed CE (pin 13) high, AS (pin 14) low, DS (pin 17) low; R/W (pin 15) toggles on alternate reads and writes; a machine that starts in terminal mode and ignores *CONFIGURE has the same checks, plus open or short circuits at IC11.
  8. ↑ 8.0 8.1 8.2 Acorn Computers, Master Series Hardware Specification, hosted as File:Acorn BBC Master Series Hardware Specification.pdf, "Additional information relating to Master Repair Guide", p. 50: for loss of configuration, replace C11 by a 100 µF capacitor (0610,100), replace D8 by a 1N4001 (0794,001), and fit a 1K8 resistor (0502,182) between base and emitter of Q3 on the solder side of the board.
  9. ↑ Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, 7.4 "Real time clock", p. 40: clock not counting, check VC1 is in circuit and 32.768 kHz at IC11 pin 2, then X1, VC1, C6, C7, R17 and R24.
  10. ↑ 10.0 10.1 10.2 stardot.org.uk, "'Metal plate' type BBC Master battery pack (ADT16)" (March 2026, retrieved 2026-10-02). 1024MAK: the lead from the three-pin connector carries a 1N4001 (or any higher-voltage 1N400x) and a 120 Ω ¼ W carbon film resistor, value not critical up to about 330 Ω; any triple-AA holder of the same layout with three 1.5 V alkaline cells; alkaline liquid can travel inside the wire insulation and corrode the wire and whatever it connects to. maniacminer: the contacts of old metal-plate packs are usually dissolved by electrolyte. Community source.
  11. ↑ 11.0 11.1 11.2 stardot.org.uk, "Corroded Master 128 battery plug" (August 2020, retrieved 2026-10-02). philpem: the plug is a Molex KK 0.1-inch three-way, and green deposits mean electrolyte has run along the wire; 8271: corrosion also tracks to nearby solder pads, so reflow the resistors next to the plug. Community source.
  12. ↑ Acorn Computers, Master Series - Battery Unit, part no. 0443,900, issue 1, January 1987, hosted as File:Acorn BBC Master Series Battery Unit 0443,900 Issue 1.pdf: black lead to the north pin of PL8, red lead to the centre pin, south pin not connected; the socket must cover all three pins.
  13. ↑ 13.0 13.1 13.2 Acorn Computers, Master 128 Main PCB Circuit Diagram, drawing 0143,000/C, sheet 2 of 2, hosted as page 2 of File:Acorn BBC Master Series Technical Drawings.pdf: PL8 with its outer pins joined to R154 (470R) and the drain of Q4 (J177), source to 0 V, gate through R155 (1M); the centre pin to the battery-backed supply of IC11 (146818, Vcc pin 24) with C11 (10 µF tantalum), D8 (1N4148) from +5 V, and R23 (10K) to the collector of Q3 (BC239), which drives IC11 CE (pin 13), with R29 (10K); X1 (32.768 kHz), VC1, R17 (5M6), R24 (100K), C6 and C7 on the oscillator; Q2 (BC213), R12, R15, R16, D5 and D6 marked N/F.
  14. ↑ Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, parts list: C11, 10 µF 35 V tantalum (0613,101); IC11, 6818 RTC CMOS (0706,818); Q4, J177 30 V P-channel FET (0780,177); Q3 among the BC239s; PL8, 3-way 0.1-inch wafer connector.
  15. ↑ Acorn Computers, Special Instructions for Replacing Batteries on the BBC Master AIV Computer, part no. 0461,004, issue 1, October 1986, hosted as File:Acorn BBC Master AIV Battery Replacement 0461,004.pdf, p. 2: hold R at power-on until "CMOS RAM reset / press Break to continue" appears.