Jump to content

Amstrad GX4000 Black Screen Repair

From RetroTechCollection
Amstrad GX4000 regulator, D183 and RAM (system-cfg forum)
Part of a GX4000 board: the L7805 regulator under its heat sink, the diodes D183 and D181 below it beside C182, the DC sockets at the right, and the two RAM chips IC10 and IC11 along the bottom edge (photo: Patrick, forum.system-cfg.com)

An Amstrad GX4000 whose power LED lights but which gives no picture and no sound with any cartridge most often has failed RAM. Patrick, writing on forum.system-cfg.com, and Markerror, on the same forum and on yAronet, both give the RAM as the usual culprit when a GX4000 is dead; Markerror names broken paddle-socket pins and damage from the two power inputs as the other common faults.[1][2][3] The console has two DC sockets side by side. J102 takes the 11 V adaptor, whose output the L7805 regulator IC181 brings down to 5 V; J101 takes 5 V from an MM12 or CM14 monitor and has only the filter L1 between it and the power switch SW1.[4] xAD of nIGHTFALL repaired a console that had been run with the 11 V plug in the 5 V socket; it needed a new Z80A and both RAM chips.[5]

Patrick, who repaired a black-screen console in 2020, also found the regulator's protection diode D183 short-circuited. Check the 5 V supply and D183 before changing the RAM.[1] Amstrad's drawings show main board MC0123A; Patrick's console had an MC0123B board with the regulator, D183 and the RAM in the same places.[4][1]

Symptoms

[edit | edit source]
  • The power LED is lit, but there is no picture on the television (RF or Peritel) or on an Amstrad monitor, no sound, and nothing changes when the paddle buttons are pressed. Several known-good cartridges give the same result.[3]
  • The two RAM chips, IC10 and IC11, become very hot within a few seconds of switching on.[1][3]

The power LED D1 is fed from the switched +5 V line through R13, so a lit LED shows that the line is live, not that it is at the right voltage.[4] Rule out the simple causes first: a cartridge that is not fully home, dirty cartridge contacts, the wrong television channel or input, and a poor Peritel lead. These are in Amstrad's problem-solving table and in the Amstrad GX4000 Troubleshooting Guide.[6] A picture on an Amstrad monitor but none on a television is a different fault, in the RGB encoder or the RF modulator; the troubleshooting guide covers it.

Safety

[edit | edit source]

The console itself carries only low voltages: up to the adaptor's 11 V at J102 and 5 V after the regulator.[4] Mains voltage is inside the adaptor, which stays plugged in for the regulator check below, so keep it on the bench away from the board and handle only the DC side.

Tools and parts

[edit | edit source]
Parts for this repair
Position Fitted by Amstrad (part number) Replacement used in the repairs cited
IC10, IC11 (RAM) KM41464AP-12 (173001)[4] Two 41464 DRAMs[1][3]
Sockets for IC10 and IC11 None; the RAM is soldered in[1] Two 18-pin DIL sockets[1]
D183 (regulator protection diode) 1SS132 (171582)[4] 1N4148[1]
IC181 (5 V regulator) L7805, 5 V 1 A (271002)[4] 7805, only if the test below condemns it[1]

Patrick bought his RAM and sockets from the French supplier e44; he found that all the parts were easy to get.[7]

Tools: a multimeter with a diode-test range, an anti-static wrist strap, a desoldering station or pump, flux, desoldering braid and a temperature-controlled iron. The general methods are on Testing Diodes, Transistors and Regulators, Through-Hole Desoldering and IC Removal and Socketing.

Procedure

[edit | edit source]

Opening the console

[edit | edit source]
  1. Switch the console off, take out the cartridge, and disconnect the adaptor, the television or monitor leads and the paddles.[6]
  2. Open the case and lift the main board out of the bottom cabinet as described in the maintenance guide. Amstrad's exploded view shows the board resting on a shield plate (part 111) in the bottom cabinet (112).[4]

Checking the regulator and D183

[edit | edit source]
Amstrad GX4000 power regulator circuit (service manual p. 29)
Amstrad's power regulator schematic: the 11 V input J102 feeds IC181, with D183 connected across it from output to input; IC181's output joins the 5 V input J101 ahead of the power switch SW1
Amstrad GX4000 main PCB, RAM and regulator area (service manual p. 24)
Where the parts are on Amstrad's board drawing: IC181 under the heat sink, D183 and D181 below it, J102 and J101 at the right, and IC10 and IC11 at the bottom

Patrick's test, checked by Gérald, uses the fact that IC181 sits ahead of the power switch: with the adaptor connected, the regulator is powered even when the console is switched off.[1][4]

  1. With the console still switched off, push the adaptor's DC plug into J102, the 11 V socket. Check that it is not in J101, the 5 V socket beside it; the two are almost the same shape.[1][3]
  2. Plug the adaptor into the mains. A label on the front of Amstrad's instructions gives this order: DC plug into the console first, then the adaptor into the mains.[6]
  3. Leave the power switch off.[1]
  4. Measure the output of IC181 to ground. If it reads 5 V, the supply is good: go on to the RAM.[1]
  5. If it does not read 5 V, unplug the adaptor, desolder one or both legs of D183 and measure again. If the output is now 5 V, D183 is faulty. If it is still wrong, replace IC181.[1] If IC181 has no input voltage at all, the fault is in the adaptor, its lead or J102; see the power table in the Amstrad GX4000 Troubleshooting Guide.
  6. Test the removed D183 on the diode range. Patrick's conducted in both directions; once it was out, his regulator gave a steady 5 V.[1]
  7. Fit a 1N4148 in place of D183.[1] Fit it the same way round as the original: on Amstrad's schematic the cathode goes to the regulator's input side and the anode to its output side.[4]
  8. Reconnect the adaptor with the console switched off and confirm 5 V at IC181's output before going further.[1]

Replacing the RAM

[edit | edit source]
Amstrad GX4000 RAM sockets fitted (system-cfg forum)
Two 18-pin sockets fitted in the IC10 and IC11 positions, at the right-hand edge of this board (photo: Patrick, forum.system-cfg.com)
  1. Unplug the adaptor. Note the notch at one end of IC10 and IC11 and the matching mark on the board legend.[4]
  2. Desolder IC10 and IC11. Patrick put flux on the joints, used a desoldering station at 300 °C, left the pins on the ground and 5 V planes until last and took those at 350 °C, cleaned the gun often to keep the suction strong, and finished stubborn holes with more flux and braid.[8]
  3. Check every pad and the track leaving it. Another owner found desoldering the GX4000's RAM laborious, and on one of his consoles tracks lifted off the board.[9] Repair any damage before going on (PCB Pad Repair, PCB Trace Repair).
  4. Solder an 18-pin DIL socket into each position, with its notch at the same end as the board legend.[1]
  5. Push the new 41464 chips into the sockets, notch to notch.[1][3]

Reassembly

[edit | edit source]
  1. Before closing the case, connect the adaptor to J102, insert a cartridge, connect a television or monitor and switch on. Patrick ran his repaired board out of its top case this way.[1]
  2. Refit the board and the top cabinet as in the maintenance guide.

Testing

[edit | edit source]
Amstrad GX4000 running after RAM replacement (system-cfg forum)
Patrick's GX4000 board after the repair, running Burnin' Rubber on an Amstrad monitor (photo: Patrick, forum.system-cfg.com)
  • With the console switched off and the adaptor in J102, IC181's output reads 5 V.[1]
  • With a cartridge inserted and the console switched on, the game's title screen appears and the paddles work. Patrick's console ran Burnin' Rubber on an Amstrad monitor straight after the repair.[1]
  • Check that the RAM no longer gets hot. The failed chips in the consoles cited here were very hot within seconds of switching on.[1][3]
  • If the screen is still black with good 5 V and new RAM, the Z80A (IC2) is next: the console nIGHTFALL repaired needed a new processor as well as new RAM.[5] After that the suspects are the AMS40489 ASIC (IC1), the crystal X1 and the cartridge connector CE101, covered in the Amstrad GX4000 Troubleshooting Guide.[4]

Use only the supplied adaptor in J102, or the power lead from an MM12 or CM14 monitor in J101.[6] An unofficial adaptor's plug can fit either socket.[3]

[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.20 1.21 1.22 Patrick, opening post of 1 February 2020 in "[Amstrad GX4000] remise en route", forum.system-cfg.com (retrieved 2026-10-25). RAM as the usual cause when the console is dead; black screen with very hot RAM; the regulator test with the adaptor connected and the console switched off; D183 (1SS132) found short-circuited in both directions; 5 V after it was removed; IC10 and IC11 desoldered and replaced in 18-pin sockets; a 1N4148 as the equivalent of the 1SS132; procedure checked by Gérald, designer of the C4CPC cartridge.
  2. ↑ Markerror, reply of 1 February 2020 in Patrick, "[Amstrad GX4000] remise en route", forum.system-cfg.com (retrieved 2026-10-25). Faulty RAM, paddle-socket pins broken because the original connectors are too stiff, and burns caused by the double power input as the classic GX4000 faults.
  3. ↑ 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 odie_one, Zerosquare, kawickboy and Markerror, "Console GX 4000 en panne ?", yAronet, February 2020 to October 2022 (retrieved 2026-10-25). Symptoms (power LED on, no picture or sound with ten cartridges on two televisions and two Peritel leads), the two DC sockets of almost the same shape, RAM very hot within seconds, RAM as the most frequent fault (Markerror), the internal regulator for the 11 V input, and the console working again after its RAM was replaced with socketed 41464 chips.
  4. ↑ 4.00 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 Amstrad plc, 464 PLUS Home Computer / 6128 PLUS Home Computer / GX4000 Games Console / MM 12 Monochrome Monitor / CM 14 Colour Monitor Service Manual, GX4000 section. Hosted as File:Amstrad GX4000 Service Manual.pdf, described at Amstrad GX4000 Service Manual. Main PCB top view p. 24; gate array and output interface schematic p. 26 (power LED D1 and R13 on the +5 V line); power regulator schematic p. 29 (J101, J102, L1, SW1, IC181, D183, C181, C183); cabinet exploded view p. 31; electrical parts list p. 36 (IC10 and IC11 KM41464AP-12, part 173001; IC181 L7805, 271002; D183 1SS132, 171582; IC2 Z8400AB1N, 40080).
  5. ↑ 5.0 5.1 xAD / nIGHTFALL, "Repairing Console Amstrad GX4000", nIGHTFALL Blog, 10 March 2013 (retrieved 2026-10-25). Fault caused by the 11 V plug resting in the 5 V monitor input; one Z80A and two 41464 RAMs replaced with parts taken from a 464 Plus.
  6. ↑ 6.0 6.1 6.2 6.3 Amstrad plc, GX4000 User Instructions (1990). Hosted as File:Amstrad GX4000 User Instructions.pdf, described at Amstrad GX4000 User Instructions. Front-cover label (connect the DC plug to the console before plugging the adaptor into the mains); English section: looking after the console p. 1 (switch off before inserting or removing a cartridge; use only the supplied adaptor or an MM12 or CM14 monitor), problem solving p. 6, connector pinouts p. 7.
  7. ↑ Patrick, reply of 2 October 2020 in "[Amstrad GX4000] remise en route", forum.system-cfg.com (retrieved 2026-10-25). RAM and sockets bought from e44, D-sub connectors from Reichelt; all the parts easy to find.
  8. ↑ Patrick, reply of 1 February 2020 (20:55) in "[Amstrad GX4000] remise en route", forum.system-cfg.com (retrieved 2026-10-25). Desoldering the RAM: flux pen, desoldering station at 300 °C, ground and Vcc pins last at 350 °C, frequent cleaning of the gun, flux and braid to finish.