Amstrad NC100 Power Fuse Replacement

The Amstrad NC100 has one fuse, F301, on its main board. Hans-Jürgen Böhling's power supply diagram draws it between the 6 V DC adaptor input and the DC/DC converter that makes the machine's supply rails.[1] Amstrad's manual does not mention the fuse, and it is a common reason for a completely dead NC100: an adaptor of the wrong voltage or polarity blows it.[2][3] The board is marked "F301(0.8A)" beside the fuse, and the rating on Tim Surtell's NC users' site is 6 V 0.8 A.[3][2] Adam Wilson's NC100, dead on four AA cells, had an open F301, and started on AA cells once the fuse was replaced.[3]
The steps below cover testing F301, finding out why it opened and replacing it. The rest of the board, including its electrolytic capacitors, is in the Amstrad NC100 Capacitor Replacement Guide.
Symptoms
[edit | edit source]- No response at all to the on switch, on fresh AA cells or on the adaptor. Wilson's NC100 showed nothing on four AA cells with F301 open.[3]
- The machine died when a different adaptor was plugged in, or after the AA cells were fitted the wrong way round. A reader of Wilson's article describes a diode, D301, that clamps the supply rail and blows the fuse when the polarity is reversed by either mistake.[4]
Other faults look the same from outside. A blank screen can also be the brightness control on the right-hand edge of the case, or flat cells.[5] A lock-up can leave the machine looking dead as well. Work through the power checks and resets in the Amstrad NC100 Troubleshooting Guide before opening the case. Its full reset erases the memory. A machine that runs on AA cells but not on the adaptor has an adaptor, lead or socket fault, not a blown F301.
Safety
[edit | edit source]- The NC100 runs from four AA cells or a low-voltage adaptor, so there is no mains voltage inside.[1] Unplug the adaptor and take out the AA cells before opening the case.[1]
- Documents, addresses and diary entries are held in battery-backed RAM and are lost if every power source is removed.[5] A dead machine cannot be backed up first, so leave the CR2032 in its holder unless it is flat or leaking.
- The CR2032 holder BT301 is on the underside of the board, close to F301 (see the photograph). Keep the soldering iron and metal tweezers clear of its contacts.[3]
Tools and parts
[edit | edit source]- Cross-head screwdriver, and a nut driver or small spanner for the four hex nuts on the serial and parallel ports.[3]
- Multimeter with continuity and resistance ranges.[3] See Continuity Testing and Signal Tracing.
- Temperature-controlled soldering iron, flux, and desoldering braid or a desoldering station.[3] See Surface-Mount Rework, or Through-Hole Desoldering for a board with the through-hole fuse.
- A replacement fuse:
- The correct adaptor for the test afterwards (see below).
The adaptor
[edit | edit source]Amstrad's instruction is to use only the adaptor supplied with the Notepad.[5] The sources differ on its rating and agree only on the voltage:
| Source | Voltage | Current | Polarity |
|---|---|---|---|
| Tim Surtell's site, adaptor rating answer[2] | 6 V DC, unregulated | 300 mA | Barrel positive, "against convention" (centre negative) |
| Tim Surtell's site, mains lead answer[2] | – | – | "Positive is the centre of the connector" |
| Adam Wilson[3] | 6 V DC | 800 mA | Centre negative |
| Böhling's power diagram[1] | 6 V DC | – | – |
Two of the three polarity statements give centre negative. Measure the original adaptor with a meter if you have it, and match any replacement to it. The same site says a regulated supply does no harm, provided its voltage and polarity are right.[2]
Procedure
[edit | edit source]
Open the case and remove the board
[edit | edit source]- Unplug the adaptor and remove the four AA cells.[1]
- Lay the NC100 face down. Remove the one screw that holds the ROM (firmware EPROM) cover.[3][1]
- Remove the four screws that hold the upper case, one of them inside the battery compartment.[3] Böhling counts five screws in all, one under the battery cover.[1]
- Turn the NC100 the right way up and lift the upper case slowly. The display's flat cable and the speaker lead are still connected to the board; pull them out of their sockets.[1]
- Unplug the keyboard's two push-fit ribbon cables.[3]
- Undo the four hex nuts on the serial and parallel ports, and lift out the board with its RF shield and insulating layer.[3]
Test F301
[edit | edit source]- Turn the board over. On Wilson's board F301 is a surface-mount part on the underside at one corner, next to three large solder tags and marked "F301(0.8A)"; other boards have a through-hole fuse.[3]
- With no power connected, measure continuity across F301. An open fuse confirms the fault.[3]
Find the cause
[edit | edit source]- Measure the adaptor that was in use, if you have it, against the table above. A wrong voltage or reversed polarity is the usual cause.[2][3]
- Before fitting a new fuse, measure the resistance from each pad of F301 to the board's 0 V. A reading close to zero on the side away from the adaptor means a short is still present; find it with Finding Short Circuits before going further.
- If the polarity was reversed, find D301 on your board and check it with the meter's diode range (see Testing Diodes, Transistors and Regulators). The reader comment on Wilson's article describes it as the diode that clamps the rail when the polarity is reversed; none of the sources used here gives its position.[4]
Replace the fuse
[edit | edit source]- Remove the old fuse with the soldering iron, then clean the pads with braid or a desoldering station.[3]
- Solder in the replacement: a 0.8 A fuse to match the board marking, or a resettable fuse as Wilson used.[3] Do not bridge the pads with wire; see Fuse Identification and Replacement.
- Check continuity across the new fuse.
Reassemble
[edit | edit source]- Refit the board with its RF shield and insulating layer, and tighten the four hex nuts on the serial and parallel ports.[3]
- Reconnect the keyboard's two ribbon cables, the display cable and the speaker lead.[3][1]
- Refit the upper case with its four screws, then the ROM cover and its screw.[3]
Testing
[edit | edit source]- Fit four good AA cells and switch on. Wilson's NC100 started on AA cells after the fuse was replaced.[3]
- A "Lithium battery is low" message means the CR2032 needs replacing. Fit the new cell with the AA cells in place, so the memory stays powered.[5] Wilson's machine gave a battery warning until its missing CR2032 was fitted, and then worked normally.[3]
- Check the adaptor's voltage and polarity, then run the NC100 from it.[2]
- If the new fuse opens as soon as power is applied, the short is still there: go back to step 10.
- If F301 is intact and the machine is still dead, look at the switch-on circuit. In Böhling's diagram the on switch S301 sets flip-flop IC313A, which switches the DC/DC converter on; IC307's ALARM, IC301's NMI and IC302's POFF lines connect to the same flip-flop.[1] The Amstrad NC100 Troubleshooting Guide lists this as the third cause of a dead machine.
Board versions and other models
[edit | edit source]- Wilson reports two main board versions, one with a through-hole fuse and one with an SMD fuse, both rated 800 mA.[3] No source says how to tell them apart without opening the case.
- Amstrad NC150: Böhling titles his power supply diagram "NC100/150", with F301 in the same place, but no source describes opening an NC150 or gives its fuse rating.[1]
- Amstrad NC200: a different machine with a 7.5 V 1 A adaptor. The NC users' site says a wrong adaptor can blow its internal fuse too; see the Amstrad NC200 Troubleshooting Guide.[2]
Related pages
[edit | edit source]- Amstrad NC100 · Amstrad NC100 Maintenance Guide · Amstrad NC100 Troubleshooting Guide · Amstrad NC100 Capacitor Replacement Guide
- Amstrad NC100 Surgical Guide · Amstrad Notepad Computer User Manual
- Amstrad NC150 Troubleshooting Guide
- Fuse Identification and Replacement · Finding Short Circuits · Surface-Mount Rework
References
[edit | edit source]- ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 Hans-Jürgen Böhling, A Surgical Guide To The Amstrad Notepad Computer. Community document, hosted as File:Amstrad NC100 Surgical Guide.pdf, described at Amstrad NC100 Surgical Guide. How to open the NC100, p. 2 (save data first; four AA cells out; five screws, one under the battery cover and one fixing the firmware EPROM cover; the display folio cable and the speaker lead still connected to the board when the upper case is lifted); "Amstrad NC100/150 Power Supply Block Diagram", p. 6 (6 V DC adaptor input, F301, four AA cells, lithium cell, DC/DC converter and battery level detector, push switch S301 and flip-flop IC313A).
- ↑ 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 Tim Surtell, Tim's Amstrad NC Users' Site, "Questions & Answers: Hardware". Retrieved 2026-10-25. "Nothing shows on the screen" (the NC200 manual's checklist; the fuse inside the NC; no fuse in the mains adaptor; the surface-mounted fuse, not documented in the manual, rated 6 V 0.8 A on the NC100; a protection diode against reversed polarity); "How can I fix my broken mains lead?" (positive is the centre of the connector); "What rating of mains adaptor should I use?" (the NC100's adaptor 300 mA at 6 V DC, unregulated; the barrel of the plug positive, against convention; a wrong voltage or polarity may blow the internal fuse).
- ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 3.23 3.24 3.25 Adam Wilson, "1992 Amstrad NC100 Notepad Computer Repair", Adam's Vintage Computer Restorations, 12 June 2023. Retrieved 2026-10-25. A dead NC100 with no adaptor: the adaptor given as 6 V DC 800 mA centre-negative; the ROM cover held by one screw and the upper case by four, one of them in the battery compartment; the keyboard on two push-fit ribbon cables and the LCD on one; the board, RF shield and insulating layer held by the four hex nuts on the serial and parallel ports; through-hole and SMD fuse versions, both 800 mA; the SMD fuse F301 found open on continuity test; old fuse removed with a soldering iron, pads cleaned with a desoldering station; a 1.1 A self-resetting 1812 SMD fuse rated to 8 V fitted; tested on four AA cells, with a battery warning until a CR2032 was fitted. Photographs img_9380 (original fuse) and img_9666 (replacement).
- ↑ 4.0 4.1 John Dunton, reader comment of 27 June 2025 on Adam Wilson, "1992 Amstrad NC100 Notepad Computer Repair". Retrieved 2026-10-25. Gives his understanding that a diode, D301, is designed to blow the fuse and clamp the supply rail when reverse polarity is applied, by wrongly fitted batteries or the wrong external supply, and argues against adding a series Schottky diode because its forward drop would shorten battery life.
- ↑ 5.0 5.1 5.2 5.3 Amstrad plc, Amstrad Notepad Computer user manual. Hosted as File:Amstrad Notepad Computer User Manual.pdf, described at Amstrad Notepad Computer User Manual. Setting up pp. 1–2 (batteries, brightness control); using the Notepad with the mains adaptor p. 4 (PDF p. 10: use only the adaptor supplied with the Notepad); powering the Notepad and the lithium battery p. 43 (memory lost if every power source is removed; the "Lithium battery is low" message).