Amstrad PCW 8256 Disc Drive Belt Replacement

From RetroTechCollection
Amstrad PCW8256 3-inch drive mechanism (service manual p. 10)
Amstrad's drawing of the PCW8256's 3-inch drive mechanism. Seen from below (lower right), the belt runs from the spindle motor pulley (6) to the flywheel (8) (service manual p. 10).

The Amstrad PCW 8256 loads all its software from drive A, a 3-inch EME-155 drive (Amstrad part 190005) mounted in a metal frame in the monitor unit.[1] The drive's spindle motor turns the disc through a thin rubber belt to the flywheel.[2] The belt is the part that wears out first, and a perished belt is the most common fault on a PCW today.[3][4] Amstrad's service agents exchanged faulty drives and were told not to repair them, so the service manual has no belt procedure of its own.[5]

The same drive is fitted, without the PCW's metal casing, in the Amstrad CPC 6128.[3] Getting the drive out of the PCW and changing the belt are described below; head cleaning, the worm-drive grease and the CPC's EME-150A drive are covered in Amstrad 6128 Disc Drive Belt Replacement. The Amstrad PCW 8512 has the same drive A and is done the same way.

Symptoms

[edit | edit source]
  • The PCW fails to boot now and then, or reports "missing address marks", while the belt still grips a little. Left alone this becomes a permanent failure to boot.[3]
  • With a Start of Day disc in drive A, the drive motor runs but the disc does not turn, and the screen stays blank.[4] Amstrad's user guide gives a bright green or flashing screen with a few bleeps as the sign that no usable Start of Day disc was found.[6]

Faults that look similar:

  • A damaged or wrong disc gives the same blank screen. Try the master disc before opening the PCW.[6]
  • If the motor does not turn at all, Amstrad's chart checks for power at the drive and then tries a known-good motor before condemning the drive.[7] No power at the drive points to the supply; see Amstrad PCW 8256 Power Supply Repair.
  • Seek errors come from the stepper motor, its drive circuit or the carriage, not the belt.[8]

See the Amstrad PCW 8256 Troubleshooting Guide for other start-up faults.

Safety

[edit | edit source]

Warning: with the back off, the CRT and the monitor board are exposed. The board carries mains voltage when the PCW is plugged in, and the tube holds a charge after it is unplugged.

  • Unplug the PCW before removing the back, and keep hands and tools away from the tube and its supply.[4]
  • The drive comes out without touching the CRT. If you need to work near the tube, discharge it first; see CRT Discharge Procedure.
  • The mains area of the monitor board is described in Amstrad PCW 8256 Power Supply Repair.

Tools and parts

[edit | edit source]
  • A replacement belt. DataServe Retro sells a belt for the PCWs with 3-inch drives, which it says also fits the CPC 664, 6128 and 6128 Plus, the DDI-1 and FD-1 and the Spectrum +3, but not the 3.5-inch drive of the PCW 9512+.[9]
  • Belt sizes disagree. The Joyce Computer Club gives the belt as a standard 72 mm belt.[3] On two CPC 6128 drives, Ewen McNeill found that a 72 × 0.5 × 3 mm belt was about 10 mm too long round and slipped, and measured a correct replacement at about 70 × 0.5 × 2.5 mm, about 220 mm in circumference.[10]
  • Head-cleaning fluid and cotton buds to clean old rubber off the pulleys.[9]
  • Screwdrivers, including one long enough to reach the screw between the drive and the main board, and tweezers or a small screwdriver to place the belt.[3]
  • A towel to lay the PCW on.[3]

Procedure

[edit | edit source]

Removing the drive

[edit | edit source]
Amstrad PCW8256 monitor unit exploded view (service manual)
Amstrad's exploded view of the monitor unit: cabinet back (20), CPU board (18), drive A (9) in its frame (7) and shield plate (8), and on the PCW8512 drive B (32) (service manual p. 22)
  1. Switch off, unplug the mains lead and disconnect the keyboard and the printer cables.[4]
  2. Lay the PCW screen-down on a towel.[3]
  3. Remove the back of the cabinet (20 on Amstrad's exploded view).[1][3]
  4. Disconnect the two cables from drive A: the power cable and the flat data cable.[3][4]
  5. Remove the four screws that hold the drive in the PCW. If your screwdriver will not reach the screw between the drive and the main board, lift the main board gently out and rest it on the monitor.[3]
  6. Lift drive A out in its metal cage.[4]
  7. Before opening the casing, check which type of drive you have. The new type (EME-155) has a casing held by four screws and a disc slot more than 1 cm wide. The old type (EME-156) has three casing screws, a 7 mm slot and a loose write-protect pin that drops out once the drive is opened.[3] Amstrad's parts list gives the EME-155 for drive A, but the Joyce Computer Club describes both types in the PCW's metal casing, so check.[1][3]
  8. Remove the casing screws and take the drive out of its casing.[3][4]

Changing the belt

[edit | edit source]
Amstrad PCW 3-inch drives opened for belt replacement (Joyce Computer Club)
Two new-type drives: on the left the circuit board has been slid back over the spindle, on the right it has been lifted to reach the mechanism (photo: Joyce Computer Club)

The Joyce Computer Club counts two board screws on the new type and three on the old; Amstrad's head-assembly procedure removes four from the control board.[3][2] Count the screws on your own drive as you remove them.

On a new-type drive (EME-155):

  1. Remove the screws that hold the circuit board.[3]
  2. Slide the board backwards and up until the hole in its middle passes over the spindle. The red LED slips out of the black front panel.[3]
  3. Lift the board about 4 cm. Leave its cables connected; that is enough room to work.[3]

On an old-type drive (EME-156):

  1. Remove the screws that hold the board.[3]
  2. Gently unplug the 2-wire and the 4-wire white connectors at the sides of the board.[3]
  3. Bend the cable holder beside the 4-wire connector slightly to free the set of five coloured wires.[3]
  4. Slide the board partly off, only as far as it will go. Two of the wires are soldered, not plugged, so do not lift it further.[3]
  5. Keep track of the write-protect pin. Without it the drive reads but will not write.[3]

Then, on either type:

  1. Take off what is left of the old belt. It runs from the spindle motor pulley to the flywheel under the disc spindle.[2]
  2. Clean every trace of old rubber from the motor pulley and the flywheel with head-cleaning fluid on a cotton bud. It is slow work, and residue left behind makes the new belt slip or ride off.[4][9]
  3. Fit the new belt round the flywheel and the motor pulley, using tweezers or a small screwdriver.[3]
  4. While the drive is open, clean the head and check the worm drive as described in Amstrad 6128 Disc Drive Belt Replacement. Amstrad's notes say to keep the head clean.[8]

Reassembly

[edit | edit source]
  1. On an old-type drive, reconnect the two connectors and make sure the write-protect pin is in place.[3]
  2. Lower the board back into place and refit its screws.[3]
  3. Refit the drive in its casing, put it back in the PCW with its four screws, and reconnect the power and data cables. Refit the main board if you lifted it.[3]
  4. Refit the back.

Testing

[edit | edit source]
  1. Reconnect the keyboard and switch on with a Start of Day disc in drive A. The screen should show a series of lines moving down from the top, then LocoScript or CP/M.[4]
  2. Load and save a few files. Occasional boot failures and "missing address marks" should have stopped.[3]
  3. If the disc turns but reads are still unreliable, Amstrad's chart adjusts the speed preset VR201 for an index period of 200 ± 1 ms; the index signal is at test point TP9. This needs an oscilloscope.[7][11] Head alignment needs Amstrad's EME-CF2 test disc.[11]

Other PCW models

[edit | edit source]
  • The PCW 8512's second drive is an EME-231, the double-sided 80-track version of the new-type drive.[1][3] Its casing and board come off in the same way.
  • The Amstrad PCW 9512 uses an EME-232, an 80-track drive of the old type wired as drive A.[3] DataServe's belt is sold for it.[9]
  • The Amstrad PCW 9512+ has a 3.5-inch drive, which does not take this belt.[9]
[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.0 1.1 1.2 1.3 Amstrad, PCW 8256/8512 Personal Computer Word Processor Service Manual, mechanical exploded view and cabinet parts list, printed pp. 22–23 (PDF pp. 23–24): Frame FDD (7), Plate FDD Shield (8), Compact Floppy Disc Drive EME-155 (9, part 190005), cabinet back assembly (20), and for the PCW8512 the Compact Floppy Disc Drive EME-231 (32, part 171224). Hosted as File:Amstrad PCW 8000 Series Service Manual.pdf, described at Amstrad PCW 8256 / PCW 8512 Service Manual.
  2. ↑ 2.0 2.1 2.2 Amstrad, PCW 8256/8512 Service Manual, p. 10, mechanism drawing and "Mechanical replacements": the key (head bracket, stepper motor, spindle motor, track 00 sensor, index/LED board, pulley, stepper shaft, flywheel, loading unit), the spindle motor procedure that removes the drive belt and ends by setting VR201 for an index period of 200 ± 2 ms, and the note that the drawing is for information only and that drives in warranty go back to Amstrad. Hosted as File:Amstrad PCW 8000 Series Service Manual.pdf.
  3. ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 3.23 3.24 3.25 3.26 3.27 3.28 Joyce Computer Club (Amsterdam), "Drive belts: 3" drives" (retrieved 2026-10-25). The belt as the most frequent PCW fault and the first part to wear out; first symptoms of occasional boot failures and "missing address marks"; removing the back with the PCW screen-down on a towel; the drive's power and data cables and its four fixing screws, and lifting the main board onto the monitor to reach the screw beside it; old (EME-156, EME-232) and new (EME-155, EME-231) drives, their casings held by three or four screws, their disc slots of 7 mm and over 1 cm, and their boards held by three or two screws; lifting the board of a new-type drive without unplugging it; the connectors, cable holder and loose write-protect pin of the old type; tweezers or a small screwdriver to fit the belt; the 72 mm belt; the same drives used without casings in the CPC computers; the EME-232 in the PCW 9512.
  4. ↑ 4.0 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 Richard Lloyd, article on the PCW8256 and PCW8512, ACUC Amstrad CPC User Club Magazine issue 1, June 2022. Scan at archive.org (retrieved 2026-10-25). The perished drive belt as the most common fault and its symptoms; rotten rubber left on the pulley that must all be removed; removing the back of the PCW, the two cables to drive A, the drive in its metal cage and the drive from the cage; the warning about the CRT's high voltages; start-up with a disc (lines moving down the screen) and without one (blank screen and beeps).
  5. ↑ Amstrad, PCW 8256/8512 Service Manual, "Important notes to service engineers", p. 3, item 2: the disc drive mechanism and its boards not to be serviced, exchange mechanisms being available. Hosted as File:Amstrad PCW 8000 Series Service Manual.pdf.
  6. ↑ 6.0 6.1 AMSOFT, PCW8256 User Guide (third edition, 1986), Appendix I, Troubleshooting, p. 142 (PDF p. 145): the screen that stays bright green or flashes, with a few bleeps, when the disc is not a Start of Day disc or is damaged, and loading from the master disc to check. Hosted as File:Amstrad PCW8256 PCW8512 User Guide (1985).pdf, described at Amstrad PCW 8256 / PCW 8512 User Guide.
  7. ↑ 7.0 7.1 Amstrad, PCW 8256/8512 Service Manual, diagnostic flow chart for FD1 and FD2, p. 6, chart 3-B "Motor rotation": does the motor rotate, is power supplied (check wiring), does it rotate with a known-good motor, and adjust VR201 to 200 ± 1 ms. Hosted as File:Amstrad PCW 8000 Series Service Manual.pdf.
  8. ↑ 8.0 8.1 Amstrad, PCW 8256/8512 Service Manual, "Software errors", p. 4: soft errors, write errors, seek errors (step motor or its drive circuit, or carriage torque), keeping the head clean, and the drive not being ready until two revolutions after a disc is inserted. Hosted as File:Amstrad PCW 8000 Series Service Manual.pdf.
  9. ↑ 9.0 9.1 9.2 9.3 9.4 DataServe Retro, "Amstrad PCW 8256 9512 Disk Drive Belt" (retrieved 2026-10-25). A belt of the original design and size for PCWs with 3-inch drives, the PCW 8256 and 9512, not the 9512+ 3.5-inch drive; also the CPC 664, 6128 and 6128 Plus, DDI-1, FD-1 and Spectrum +3; all traces of the old belt to be removed from the motor capstan and pulley with head-cleaning fluid, as residue makes a new belt slip or ride up and come off.
  10. ↑ Ewen McNeill, "Working with Amstrad CPC 3 inch floppy discs", 18 March 2018 (retrieved 2026-10-25). A 72 × 0.5 × 3 mm belt fitted in 2004 that was about 10 mm too long in circumference and slipped; the DataServe replacement measured at about 70 × 0.5 × 2.5 mm, about 220 mm round.
  11. ↑ 11.0 11.1 Amstrad, PCW 8256/8512 Service Manual, alignment checks, p. 11: the double-beam oscilloscope and EME-CF2 (EME-CF2DD) test disc, and the list of test points (TP1 and TP2 read signal, TP3 and TP11 signal ground, TP5 track 00 sensor, TP9 index). Hosted as File:Amstrad PCW 8000 Series Service Manual.pdf.