Jump to content

Amstrad PCW 9256 Power Supply Repair

From RetroTechCollection
Amstrad PCW9256 monitor PCB layout
Amstrad's layout of the PCW9256 monitor board, which carries the switch-mode supply for the whole machine (service manual p. 4).

The Amstrad PCW 9256 takes its +24 V, +12 V and +5 V from a switch-mode supply on the monitor board (PCB001, MM0059) in the main unit. The supply is built round an STK7308 switching regulator (IC501). Each output has its own winding on T501, a rectifier, a power amp transistor and a regulator, and the 12 V output also feeds the monitor's horizontal drive.[1][2] The circuit is close to the PCW 8256's, which also uses an STK7308, but the designators, several values and the fuse rating differ; see Amstrad PCW 8256 Power Supply Repair for that machine and Amstrad PCW 9512+ Power Supply Repair for the 9512+.

The service manual gives the circuit, a loaded output check and a parts list, but no fault-finding chart for the supply.[3]

Symptoms

[edit | edit source]
  • Nothing at all at switch-on. Suspect the mains lead, then F501, then the primary side of the supply.[1]
  • One output missing or low while the others work. The three outputs have separate windings, rectifiers and regulators, so one can fail on its own.[1]
  • An output that will not set to value with VR502 or VR501, or that collapses under Amstrad's test load.[3]
  • A screen with no raster while the machine otherwise starts can be the 12 V output, which also feeds the horizontal drive transistor Q405.[1]

Work through the Amstrad PCW 9256 Troubleshooting Guide first; it covers the start-up and screen symptoms that are not supply faults.

Safety

[edit | edit source]

Warning: the monitor board carries mains voltage, and the CRT and C505 hold a dangerous charge after the plug is pulled.

  • The mains side runs from the AC input board MS0233 and the switch board MS0228 through F501, the line filter L501 and the bridge rectifier to C505, the STK7308 and the primary of T501. The schematic divides the board into "hot" and "cold" sides.[1] Treat everything on the hot side as live whenever the PCW is plugged in.
  • C505 is the 150 µF 400 V reservoir across the bridge output.[2][1] Measure it and discharge it through a suitable resistor before touching the board.
  • Discharge the CRT before working near the tube or the flyback transformer FB401; see CRT Discharge Procedure.[2]
  • Make resistance checks on the hot side with the machine unplugged. If a live measurement there cannot be avoided, run the PCW from an isolating transformer.
  • Parts marked with a triangle are critical for safety; replace them only with the types in the parts list.[1][2]
  • After any work, Amstrad requires a 4 kV flash test between the joined mains live and neutral and every accessible metal point outside, and at least 4 MΩ insulation resistance between the same points.[4]

How the supply works

[edit | edit source]
Amstrad PCW9256 power supply primary side (service manual schematic)
The mains side: the AC input and switch boards, F501, L501, the bridge D501–D504, C505, the STK7308 (IC501) and the over-load protector Q513 (service manual p. 9)

Mains side

[edit | edit source]

Mains enters on the AC cord CD501 at the AC input board MS0233 and passes through the power switch SW501 on board MS0228. On the monitor board it goes through F501 (T 3.15 A 250 V) in fuse holders FH501 and FH502 and the line filter L501 to the bridge rectifier D501–D504 (20E10). R501 (5.6 Ω 5 W) feeds the reservoir C505. The STK7308 (IC501) switches the primary of T501, and Q513 (2SD1207) is labelled "over load protector".[1][2] Other primary-side resistors are R502 (1.5 Ω 3 W), R503 (1 kΩ 1 W), R505 (3.9 kΩ 1 W) and the 15 Ω ¼ W fuse resistor R532.[2]

Outputs

[edit | edit source]
Amstrad PCW9256 power supply secondary side (service manual schematic)
The low-voltage side: the 12 V, 24 V and 5 V outputs, their protect stages and CP102 (service manual p. 9)
Supply outputs (monitor schematic and parts list)
Output IC protector Rectifier Reservoir Power amp Regulator Adjust CP102 pin
+12 V (also the horizontal drive) ICP502, PRF-2500-F004 D507, 30DF2 C518, 470 µF 35 V Q502, 2SD1666 IC502, AN6531 VR502 4
+5 V ICP501, ICP-N75 D506 and D514, 30DF2 C517, 470 µF 16 V Q501, 2SD1667 IC503, AN6531 VR501 3
+24 V None D508, 30DF2 C519, 470 µF 50 V Q503, 2SD1666 IC504, L7824V-SA None 5

Source: the monitor schematic and the parts list.[1][2] The 24 V output has no IC protector on the schematic, and the parts list lists only ICP501 and ICP502.

The 5 V output passes through R508 and the 24 V output through R516, both 0.27 Ω 2 W, with over-load protect transistors Q504 and Q512 (KTA1266Y) beside them. The schematic also shows a "24V protect" stage (Q508–Q511) and a "5V protect" stage (Q505–Q507).[1][2] C526 (470 µF 35 V) sits on the 24 V output.[1][2]

CP102 on the monitor board carries the supply to the main board: pin 5 +24 V, pin 4 +12 V, pin 3 +5 V, pin 2 the 12 V and 5 V ground, and pin 1 the 24 V ground.[1][3]

Tools and parts

[edit | edit source]
  • A digital multimeter. An oscilloscope helps with a noisy output.
  • For Amstrad's output check, electronic loads (or power resistors) for 1.8 A at 5 V and 1.2 A each at 12 V and 24 V.[3]
  • An isolating transformer for any measurement on the hot side, and a discharge tool for the CRT and C505; see CRT Discharge Procedure and Recommended Tools.
Power supply parts in Amstrad's parts list
Ref Part Amstrad part no.
F501 Fuse BET 3.15 A (T) 250 V 171531
FH501, FH502 Fuse holder H0060 –
L501 Line filter SU16V-10060 272796
D501–D504 20E10FA13 171048
R501 5.6 Ω 5 W cement 272214
C505 150 µF 400 V 157792
IC501 STK7308 170445
R532 15 Ω ¼ W fuse resistor 1420155
T501 Switching transformer 81390141 272799
ICP501 ICP-N75T104 171057
ICP502 PRF-2500-F004 272807
D506, D514 30DF-2FC 171052
D507, D508 30DF2-FIN (printed "30FD2-FIN") 272767
IC502, IC503 AN6531 171041
IC504 L7824V-SA 177043
Q501 2SD1667 177045
R508 0.27 Ω 2 W 272780
VR501 Preset RH0638C13R02A 272792
VR502 Preset RH0638CS3R02A 272793
C518 470 µF 35 V 150919
C519 470 µF 50 V 272785

Source: Amstrad's parts list.[2] The transistor entries in the list do not match the schematic: they group Q502, Q503, Q506, Q508, Q510, Q512 and Q513 as 2SD1666, where the schematic shows Q506, Q508, Q510 and Q512 as KTA1266Y and Q513 as a 2SD1207. The resistor list also gives R516 twice, as 0.27 Ω 2 W and as 330 Ω 2 W; on the schematic the 330 Ω 2 W parts are R515 and R518. Go by the schematic and the marking on the part. The full list of electrolytics is in the Amstrad PCW 9256 Capacitor Replacement Guide.

Procedure

[edit | edit source]

Opening the main unit

[edit | edit source]
  1. Switch off and unplug the mains lead. Disconnect the keyboard and the printer.
  2. Remove the cabinet back (115 on Amstrad's monitor cabinet exploded view) to reach the monitor board.[5] Keep hands and tools away from the tube and its supply.
  3. Discharge the CRT and C505 before going further.

Checks with the power off

[edit | edit source]
  1. Check F501 for continuity.[1]
  2. If F501 has blown, find the cause before fitting a new fuse. Test the four 20E10 diodes D501–D504 on the diode range, check C505 for a short, and check R501. A short that remains across C505 with the bridge and C505 good points to the STK7308.[1]
  3. Check R502 (1.5 Ω), R503 (1 kΩ), R505 (3.9 kΩ) and the fuse resistor R532 (15 Ω) against their values.[2]
  4. On the low-voltage side, check ICP502 (12 V) and ICP501 (5 V) for continuity.[1] An open protector means that output drew too much current. Before replacing it, test that output's rectifiers on the diode range, check its reservoir capacitor and check its power amp transistor for a collector–emitter short.[1][6]
  5. The 24 V output has no IC protector. If it is dead, test D508, C519 and Q503 directly.[1]
  6. Look for bulging or leaking electrolytics in the supply area; the values are in the Amstrad PCW 9256 Capacitor Replacement Guide.

Checks with the power on

[edit | edit source]
Amstrad PCW9256 power supply load test (service manual Fig. 2-1)
Amstrad's Fig. 2-1: connector A unplugged from CP102 and loaded for the output check (service manual p. 3)
Amstrad PCW9256 monitor board adjustment locations (service manual p. 3)
VR502 (+12 V), VR501 (+5 V) and CP102 on the monitor board (service manual p. 3)

With the back off, the hot side of the board is exposed whenever the PCW is plugged in. Attach the meter leads with the power off, switch on, read the meter, then switch off and unplug before moving them.

  1. Unplug connector A from CP102. The chart's text says to disconnect "CP101", but its Fig. 2-1 shows connector A coming off CP102, the supply connector.[3]
  2. Connect loads to connector A as in Fig. 2-1: 1.8 A on 5 V and 1.2 A each on 12 V and 24 V.[3]
  3. Turn VR401 to maximum, as the chart does for the 12 V and 5 V steps.[3][2]
  4. Switch on and measure 24 V. Amstrad's limit is ±1 V, and there is no adjuster.[3][1]
  5. Set 12 V with VR502 to within ±0.01 V.[3]
  6. Set 5 V with VR501 to within ±0.05 V.[3]
  7. If an output is missing or will not set, follow it back through its stage with the voltages below.
DC voltages printed on Amstrad's monitor schematic
Output Power amp: collector, base, emitter Regulator IC
+12 V Q502: 13.7 V, 12.6 V, 11.9 V IC502 (AN6531): pin 1 4.9 V, pin 2 0 V, pin 3 29.3 V, pin 4 13.0 V
+24 V Q503: 32.3 V, 24.3 V, 23.7 V IC504 (L7824V-SA): pin 1 31.0 V, pin 2 0 V, pin 3 24.4 V
+5 V Q501: 7.3 V, 5.8 V, 5.21 V IC503 (AN6531): pin 1 4.9 V, pin 2 to ground, pin 3 12.2 V, pin 4 5.8 V

Source: the monitor schematic, which writes zero with a stroke through it.[1] The schematic does not give the load under which these were taken, so use them to find the failed stage, not as limits. The voltages printed at the STK7308's pins are on the hot side; measure them only with the PCW running from an isolating transformer.

Replacing parts

[edit | edit source]

Testing

[edit | edit source]
  1. With the outputs loaded as in Fig. 2-1, check 24 V within ±1 V, 12 V within ±0.01 V and 5 V within ±0.05 V.[3]
  2. Reconnect connector A to CP102, refit the back and start the PCW from its start-up disc.
  3. Print a page to load the 24 V output.
  4. If you replaced any part on the hot side, have the unit checked with Amstrad's flash and insulation tests before regular use.[4]
[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 Amstrad, PCW9256 Personal Computer Word Processor Service Manual, monitor schematic diagram, p. 9: the AC input board MS0233, switch board MS0228, F501, L501, the bridge rectifier, C505, the STK7308 switching regulator and its pin voltages, the over-load protector Q513, the 12 V, 24 V and 5 V outputs with their IC protectors, rectifiers, power amps, regulators and protect stages, the printed DC voltages, connector CP102, and the safety-critical parts marked with a triangle. Hosted as File:Amstrad PCW 9256 Service Manual.pdf, described at Amstrad PCW 9256 Service Manual.
  2. ↑ 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 Amstrad, PCW9256 Service Manual, electrical parts list, p. 16 (PDF pp. 16–17): ICs, transistors, diodes, coils, PCB assemblies, presets, switches, F501, IC protectors, fuse and cement resistors, electrolytic and film capacitors and metal oxide resistors, with Amstrad part numbers. Hosted as File:Amstrad PCW 9256 Service Manual.pdf.
  3. ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 Amstrad, PCW9256 Service Manual, alignment chart for the monitor, p. 3: steps 1–3 check 24 V to ±1 V and set 12 V with VR502 to ±0.01 V and 5 V with VR501 to ±0.05 V at connector A, with "CP101" disconnected, VR401 at maximum for the 12 V and 5 V steps, and the outputs loaded as in Fig. 2-1 (1.8 A on 5 V, 1.2 A each on 12 V and 24 V); the component location drawing of the monitor board. Hosted as File:Amstrad PCW 9256 Service Manual.pdf.
  4. ↑ 4.0 4.1 Amstrad, PCW9256 Service Manual, safety test, p. 2: the 4 kV flash test and the insulation resistance test of at least 4 MΩ after any work. Hosted as File:Amstrad PCW 9256 Service Manual.pdf.
  5. ↑ Amstrad, PCW9256 Service Manual, monitor cabinet exploded view and parts list, p. 15: the cabinet back (115), shields, frames and holders, and the boards PCB001–PCB008. Hosted as File:Amstrad PCW 9256 Service Manual.pdf.
  6. ↑ ROHM, "IC protector" data sheet (surface-mount ICP-S and leaded ICP-N series). Copy at static.chipdip.ru. Retrieved 2026-10-25. Low internal resistance in normal use and a fast cut-off above the cut-off current; not to be used on the primary side of mains supplies.