BBC Master 128 Keyboard Repair

The keyboard of the BBC Master 128 has 93 keys. 92 of them form a matrix of 8 rows and 13 columns, scanned by a keyboard encoder, IC16, a 40-pin chip on the main board, through two 15-way connectors, PL11 and PL24; the BREAK key is wired separately.[1] Acorn's service manual allows for a second arrangement in which the encoder is on the keyboard and a single 17-way connector joins it to the board.[2] The same board and keyboard are in the Acorn Master Turbo, BBC Master 512, BBC Master ET and BBC Master AIV.[3]
Chris Richardson of 8-Bit Software describes two mechanical types: the first has keyswitches soldered to a printed circuit board, the same switches as the Acorn Electron; the newer type has two plastic membranes separated by a layer with holes in it, and the keys clip into a plastic layer above them.[4] The BBC Master Compact keyboard is different again.
Symptoms
[edit | edit source]| Symptom | Where to look |
|---|---|
| One key dead or intermittent | The keyswitch, or a break at the far end of its row or column track[2][4] |
| Several keys dead | The connection from IC16 to the keyboard, or a break part-way along a row or column track[2] |
| BASIC prompt, but no key does anything | System VIA IC8, connections to IC16, the IRQ line; try another keyboard[2] |
| Only a cursor at the top left of the screen | Connections to the keyboard and encoder IC16, then IC16[5] |
| BREAK does nothing | The BREAK lock: a cam that, turned through 90 degrees, stops the key going down[1] |
| Large parts of the keyboard dead, with a constant background tone and a corrupt configuration | A slow data bus line held low. On one Master 512, SA0 (system VIA IC8 pin 2, encoder IC16 pin 34, sound chip IC12 pin 10, clock chip IC11 pin 4) was held at about 0.04 V by a failed 146818 clock chip near old battery leakage; a new 146818 cured it. See BBC Master 128 Battery Backup Circuit Repair[6][7] |
Other faults are in the BBC Master 128 Troubleshooting Guide.
Safety
[edit | edit source]Unplug the mains lead before opening the case: the power supply is under the lid beside the keyboard, and the keyboard is screwed to it.[8] The supply's own hazards are in the BBC Master 128 Maintenance Guide.
Tools and parts
[edit | edit source]- A multimeter with a continuity range. See Recommended Tools.
- A solder pump or braid, and isopropyl alcohol, for the first keyboard type.[4]
- A replacement switch of the same type from a donor keyboard. Chris Richardson recommends fitting a working switch, because cleaned switches often fail again within days.[4]
- A spare keyboard for substitution, if available; Acorn's own fault-finding uses one.[2]
Procedure
[edit | edit source]Open the case and remove the keyboard
[edit | edit source]- Unplug the mains lead and all peripherals. Turn the computer over and remove the four fixing screws underneath; Chris Richardson notes the two rear ones are long and the two front ones short.[8][4]
- Hold the halves together, turn the computer back over and lift the top off.[8]
- Unplug the keyboard's two connectors from the main board.[8]
- Undo the three screws holding the keyboard to the case bottom and the one screw holding it to the power supply, and lift the keyboard out.[8]
- Push each ribbon connector on and off a few times; a dirty connection here can cause the fault on its own.[4]
Find the line that has failed
[edit | edit source]
- Find each dead key on Acorn's keyboard diagram and note its row and column.[9] Keys that fail together and share a line point to that line.
- Test continuity along the line from the dead key's switch to its pin on the keyboard connector. The main-board ends are listed below.[10] Acorn's note matters here: the "beginning" of a row or column is the end of the track that connects to the encoder, and it is not always the end that looks nearer to it on the board. One dead key means a break near the far end of its track; several dead keys mean a break part-way along it.[2] Continuity Testing and Signal Tracing covers the method.
| Pin | PL11 | PL24 |
|---|---|---|
| 1 | C6 | C8 |
| 2 | BAT | C7 |
| 3 | R0 | C3 |
| 4 | R6 | C1 |
| 5 | R7 | R5 |
| 6 | R2 | R4 |
| 7 | R1 | R3 |
| 8 | C11 | C |
| 9 | C10 | Shift Lock LED |
| 10 | C12 | Caps Lock LED |
| 11 | C0 | Power LED |
| 12 | C2 | S |
| 13 | C9 | KBD SW |
| 14 | C4 | 0 V |
| 15 | C5 | +5 V |
R0 to R7 are the rows and C0 to C12 the columns. C and S on PL24 carry the CTRL and SHIFT keys, which Acorn's keyboard drawing wires outside the matrix, and BAT is the connection for the optional rechargeable battery on the keyboard, not fitted as standard.[10][9][11]
First type: soldered keyswitches
[edit | edit source]
- Use the key firmly for a minute; then ease the keycap off with a small screwdriver and work the switch and blow into it. Unused keyboards often recover this way.[4]
- With the keyboard out, check the faulty switch's solder joints and test across its pins with a continuity tester. Reheat a dry joint.[4]
- To remove a switch, heat each of its two soldered pegs and clear the solder with a pump, or heat both together and push the switch out. Wash it in isopropyl alcohol or, better, fit a working switch.[4] See Through-Hole Desoldering.
- Repair a broken track by scraping the varnish off and soldering a wire across the break.[4] See PCB Trace Repair.
- Resolder LED leads that have worked loose.[4]
Second type: membrane keyboard
[edit | edit source]
- On this type a key presses the top membrane onto the bottom one through a hole in the middle layer. A foreign object trapped between the layers can stop a key working; look for one first.[4]
- The keys are clipped into a plastic layer above the membrane, and each keyswitch peg can be pushed out from the underside to free it.[4]
- Do not dismantle the LED assembly, which contains tiny springs.[4]
- Check the membrane tracks for continuity as above. Keyboard Membrane Trace Repair covers repairing a broken printed track.
Check the main board side
[edit | edit source]- If the keyboard tests good, or a different keyboard has the same fault, check the connections from PL11 and PL24 to the encoder IC16, and then IC16 itself.[2][5]
- If no key responds, check the address and chip select lines of the system VIA IC8, and that the IRQ line at IC14 pin 4 is not stuck. The memory controller IC20 and the clock chip IC11 also drive IRQ; link LK4 isolates IC11.[2]
Reassemble
[edit | edit source]- Refit the keyboard with its four screws, three to the case and one to the power supply.[8]
- Push both ribbon sockets fully home over every pin; they are easily displaced one pin to the right or left.[8]
- Refit the top and its four screws.[8]
Testing
[edit | edit source]- Every key types correctly, including SHIFT, CTRL and the numeric keypad.
- Caps Lock and Shift Lock light their LEDs, and the power LED is lit.[9]
- BREAK resets the machine when its lock is open.[1]
Related pages
[edit | edit source]- BBC Master 128
- BBC Master 128 Troubleshooting Guide
- BBC Master 128 Maintenance Guide
- BBC Master 128 Battery Backup Circuit Repair
- BBC Micro Model A/B Keyboard Repair
- BBC Master Series Service Manual
- BBC Master Series Documentation
References
[edit | edit source]- ↑ 1.0 1.1 1.2 Acorn Computers, Master Series Microcomputer Service Manual, part no. 0443,004, issue 1, April 1986, "Keyboard", pp. 19–20: 93 keys, 92 in a modified 8 × 13 matrix scanned by the keyboard encoder IC16; pressing a key in free-run mode raises an IRQ through the system 6522's CA input, except SHIFT and CTRL; BREAK resets the CPU and has a mechanical lock, a plastic cam turned through 90 degrees to stop the keytop going down; slow bus PA0 to PA3 select the column and PA4 to PA6 the row, PA7 reports a pressed key; row inputs R0 to R7 held high by internal pull-ups; open-collector column outputs C0 to C14 scanned at 1 MHz in free-run mode; nKBEN from the system VIA switches to polled mode.
- ↑ 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, 7.1.7 and 7.1.8, pp. 35–36: keyboard not responding, check the system VIA IC8 address and chip select lines, the connections to IC16, try another keyboard and look for broken leads and tracks on the original, and check the IRQ line at the CPU IC14 pin 4, to which IC20 and the clock chip IC11 (isolated by link LK4) also connect; not all keys working, with either a 40-pin encoder IC16 on the main board and two 15-way connectors (possibly with an intermediate buffer board), or a 17-way connector to a keyboard carrying the encoder; several keys affected, check the connection from IC16 to the keyboard and look for a broken track in the middle of a row or column; one key affected, a broken track at the end of a row or column, or the keyswitch; the beginning of a row or column is the end of the track connected to the encoder, not necessarily the end visually nearer to it.
- ↑ BBC Master 128 Troubleshooting Guide: the Master 128 board is shared by the Master Turbo, Master 512, Master AIV and Master ET.
- ↑ 4.00 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 Chris Richardson, "Repairing Keyboards", 8-Bit Software, 2000 and 2003 (retrieved 2026-10-25). Master 128: lid held by four screws underneath, two long ones at the rear and two short ones at the front; keyboard held by four screws, three larger ones and a small one with a clip to the power supply; two ribbon cables push onto the main board; reseating them; Type 1 keyboard with switches soldered by two pegs, the same switches as the Electron, desoldered with a pump, washed in isopropyl alcohol or replaced; broken tracks repaired with wire over scraped varnish; LED leads working loose; Type 2 keyboard made of two membranes separated by a layer with holes, a foreign object between the layers stopping a key; keyswitch pegs pushed out from the underside; the keys clip into a plastic layer containing the tracks; the LED assembly contains tiny springs and should not be dismantled. Community source.
- ↑ 5.0 5.1 Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, 7.1.4, p. 34: a cursor stuck at the top left of the screen and nothing else; disconnect any co-processor, check all connections to and from the keyboard and keyboard encoder IC16, and replace IC16.
- ↑ stardot.org.uk, "Master 512 keyboard issues - 6522? (Solved - bad RTC)" (November–December 2024, retrieved 2026-10-02). Boydie: SA0 stuck low, constant tone, many dead keys; replacing IC8 twice made no difference; cutting pin 4 of IC11 freed the line and a new 146818 completed the repair. 1024MAK: the lines SA0 goes to (IC8 pin 2, IC16 pin 34, IC12 pin 10, IC11 pin 4) and how to measure a stuck line. Community source.
- ↑ BBC Master 128 Troubleshooting Guide, switch-on section: the same Master 512 case, with the clock chip sitting near old battery leakage.
- ↑ 8.0 8.1 8.2 8.3 8.4 8.5 8.6 8.7 Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, 3 "Disassembly and assembly", pp. 6–7: four fixing screws underneath the case, and the lid is not to be removed with the mains connected; four sub-assemblies (keyboard, speaker and battery unit, power supply, main board); to remove the keyboard, unplug its two connectors from the main board and undo the three screws to the case bottom and the one screw to the power supply; on reassembly, refit the four screws and make sure the keyboard ribbon sockets engage every pin, since they are easily displaced one pin to the right or left.
- ↑ 9.0 9.1 9.2 Acorn Computers, Keyboard (Plain) Project 'B' PCB Circuit Diagram, drawing 0143,201/T, hosted as page 3 of File:Acorn BBC Master Series Technical Drawings.pdf: the key matrix with the pin number of each row and column line on keyboard connectors PL1 and PL2; BREAK switch SW1; SHIFT (two keys) and CTRL wired outside the matrix; LED 1 power on, LED 2 Caps Lock, LED 3 Shift Lock; primed keys are on the numeric keypad.
- ↑ 10.0 10.1 10.2 Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, connector pinouts, p. 56: PL11 and PL24, keyboard, 2 × 15-pin Molex; PL11 pins 1 C6, 2 BAT, 3 R0, 4 R6, 5 R7, 6 R2, 7 R1, 8 C11, 9 C10, 10 C12, 11 C0, 12 C2, 13 C9, 14 C4, 15 C5; PL24 pins 1 C8, 2 C7, 3 C3, 4 C1, 5 R5, 6 R4, 7 R3, 8 C, 9 Shift Lock, 10 Caps Lock, 11 Power, 12 S, 13 KBD SW, 14 0VB, 15 +5VB.
- ↑ Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, "Real time clock with RAM", p. 21: components for a rechargeable battery on the keyboard are not fitted as standard.