Amstrad PC2386 power supply board MP0001A layout (service manual p. 8)
Amstrad's layout of the PC2386 power supply board MP0001A (service manual p. 8). The mains fuse F601 (T 4A) is at bottom left, the switching regulator IC601 and the optocouplers Q602 and Q603 in the middle, and the presets VR603 (+12 V), VR604 (+5 V) and VR606 (12 V protection) at the right-hand edge

The Amstrad PC2386 has its own switch-mode power supply in the system unit: board PCB601 (MP0001), mounted on a metal frame with its own fan, M601. Amstrad's notes to engineers rule out component-level repair of the main CPU board and the drives, but state that the supply and monitors are subject to component-level repair, and the service manual gives the supply's parts list, alignment and a schematic with DC voltages printed at the main test points.[1][2]

The schematic shows several protection circuits, and owners of failed supplies of this design describe a fan that turns for a moment and stops. The procedure below follows the circuit from the mains input through the switching regulator and the protection loop to the outputs, with Amstrad's printed voltages and what owners found on failed supplies. One PC2386 owner brought a dead supply back by replacing leaking capacitors and a faulty optocoupler.[3] The Amstrad PC2286 supply uses the same ICs and the same capacitor values in the same positions, according to an owner's list, so owners' reports from PC2286 supplies are included below and marked as such.[4][1]

Symptoms

[edit | edit source]
  • The fan turns for about a second and stops, and a connected floppy drive flashes its light once. Owners of three PC2286 supplies reported this, with and without a load; on one, measurements showed the protection switching the supply off.[4][5][6]
  • No output at all after long storage: on the PC2386 above, leaking capacitors and a failed optocoupler.[3]
  • Before blaming the supply, try it with the drives disconnected. On an Amstrad PC2086, whose supply is a different design, the same half-second start and shutdown came from a short on the hard disc's circuit board.[7]

The Amstrad PC2386 Troubleshooting Guide covers faults that look like a supply fault but are not, such as stripes on the screen with good voltages.

Safety

[edit | edit source]

Warning: the supply's primary side runs at rectified mains voltage. Amstrad prints 306 V DC on the reservoir line and a 440 V peak-to-peak waveform at the switching transistor, and the reservoir capacitor C601 (330 µF 400 V) holds its charge after the mains lead is removed.[2][1]

  • Unplug the machine and discharge C601 through a suitable resistor before touching the board.
  • The schematic marks a hot (primary) and a cold (secondary) side. Measure primary-side voltages against the primary ground, IC601 pin 5, and secondary voltages against the output ground; an owner measuring the PC2286 supply used IC601 pin 5 as his reference for the primary.[2][5] An isolating transformer makes live primary measurements safer.
  • Parts marked with Amstrad's safety triangle are critical for safety; the schematic says to replace them only with the parts in the parts list.[2]
  • After any repair, Amstrad's safety tests are a 1.5 kV RMS flash test for 3 s, an insulation resistance above 4 MΩ and mains-lead earth continuity of no more than 0.5 Ω.[1]

Tools and parts

[edit | edit source]
  • A multimeter, an isolating transformer, an ESR meter for the electrolytics and, for the switching waveform, an oscilloscope.
  • A load for testing: the PC2286 supply would not start with no load connected.[6] Use the main board and a drive, or a dummy load on the output connectors.
PC2386 supply parts named in this guide (service manual pp. 44–45 and 48)
Ref Part Amstrad part no. Label or position on the schematic
F601 T 4A fuse – Mains fuse, in holders FH601 and FH602
IC601 STK7458 176648 Switching regulator (power IC) with the switching transistor inside
IC602 MB3761M 176649 Protection, primary side
Q601 2SA1346-AC compound transistor 176660 Protection, between IC602 and IC601
Q602 TLP732 (LF2) photocoupler 176087 Regulation feedback across the isolation barrier
Q603 TLP741G (LF2) photocoupler 176659 Protection sense across the isolation barrier
IC603 LA6324 170112 Error amplifiers (+5 V, +12 V)
IC604 BA707 171481 Regulator on the secondary side
IC605 BA6993 171480 +5 V and +12 V overload protection comparators
IC606 AN7905F 176652 −5 V regulator
IC607 AN7912T 176653 −12 V regulator
Q614 2SB1135R 176661 +12 V series regulator
Q615 2SD1207-AE 170741 +12 V driver
Q606, Q616 KTC1815Y 170447 Protection; Q616 is the over-voltage and over-temperature protection
D601–D604 20E10FA13 176039 Mains bridge
D614 F10P20F 176621 +12 V rectifier
D616 30GWJ2C42 176622 +5 V rectifier
R602 4.7 kΩ fuse resistor 176739 Primary side, IC601
R609 0.22 Ω 5 W cement 176741 IC601 source resistor
R658 1 kΩ ¼ W – In series with Q602's LED (pin 1)
VR601 100 kΩ preset 176672 Primary protection
VR603, VR604, VR606 1 kΩ preset 176673 +12 V adjust, +5 V adjust, 12 V protection adjust

The electrolytic capacitors, with values, voltages and part numbers, are tabled in the Amstrad PC2386 Capacitor Replacement Guide.[1]

Procedure

[edit | edit source]

Remove the supply

[edit | edit source]
Amstrad PC2386 power supply assembly, cabinet exploded view (service manual p. 47)
The supply assembly in Amstrad's cabinet exploded view (p. 47): PCB601 on the frame power bottom (10) under the frame power top (8), with the power switch button (9) at one end and the fan at the other
  1. Unplug the mains lead and every cable from the system unit.
  2. Remove the cabinet top. Amstrad's exploded view shows its screws under screw caps (3).[2]
  3. Unplug the supply's output connectors. The main board connector is CD602; the drive power leads are CD603 and CD604 (floppy drives), CD605 (hard disc) and CD606 (external floppy drive), and the fan plugs into CP601.[2]
  4. Unscrew the supply assembly and lift it out. The board PCB601 sits on the frame power bottom (10) under the frame power top (8), with a push button (9) that works the power switch SW601.[2]
  5. Remove the frame power top to reach the board, then discharge C601.

Check the primary side, unpowered

[edit | edit source]
Amstrad PC2386 power supply schematic, primary side and STK7458 (service manual p. 48)
The primary side of Amstrad's supply schematic (p. 48): mains input through F601 (T 4A) and L601 to the bridge D601–D604 and C601, then IC601 STK7458 with Amstrad's printed DC voltages at its pins
  1. Check the fuse F601 (T 4A). If it has blown, look for a short on the primary side before fitting a new one. One PC2286 seller described a blown fuse that turned out to be intact.[2][4]
  2. Check the thermistor TH601, the line filter L601 and the bridge diodes D601 to D604 (20E10FA13) for open or short circuits.[2][1] See Testing Diodes, Transistors and Regulators.
  3. Check the fuse resistor R602 (4.7 kΩ) and the source resistor R609 (0.22 Ω 5 W) for an open circuit.[1]
  4. Look over the whole board for corrosion and broken tracks. On a PC2286 supply stored in a damp, unheated place, R658 (1 kΩ) and the track beside it had both broken; the owner washed the board with water, washing-up liquid and a toothbrush, let it dry and bridged the track.[4]
  5. Check the large electrolytics on the secondary side for leakage, especially C625 (3300 µF 35 V) and C627 and C628 (6800 µF 16 V). On PC2286 supplies, C625 had leaked at its positive leg and both 6800 µF capacitors had leaked and corroded the board.[8][6] GiGaBiTe advised replacing leaking capacitors before any further fault-finding, since conductive electrolyte between tracks can cause faults of its own.[8]

Check the switching regulator, powered

[edit | edit source]

With the supply connected to its load and the mains applied through an isolating transformer, compare the voltages at IC601 with Amstrad's figures, measured against pin 5.[2]

IC601 STK7458 pin voltages (schematic p. 48)
Pin 1 (STR) 3 (V7) 4 (VCC) 5 (GND) 6 (CT) 7 (RT) 8 (RFF) 9 10 (SES) 11 12 (DT) 14 (S)
Volts 306.0 13.3 15.1 0.0 1.6 3.7 5.0 9.9 2.5 3.1 1.4 0.03
  1. Measure pin 1. It sits on the reservoir line, so 306 V means the mains input, bridge and C601 are working. An owner saw more than 200 V across the PC2286's primary capacitor while every secondary capacitor had none.[2][8]
  2. Measure VCC at pin 4 (15.1 V), held by the zener D611 (GZA18Y) and C610 (47 µF 50 V).[2][1]
  3. Compare the remaining pins with the table. Replacing the STK7458 on the PC2286 supply that shut down made no difference, and its pin voltages did not change, so the protection loop below should be checked before buying a new IC601.[8]

Because the supply shuts itself down within a moment of switch-on when the protection trips, readings taken a few seconds after switch-on show the shut-down state, not the fault.[5][9]

Follow the protection loop

[edit | edit source]
Amstrad PC2386 power supply schematic, protection circuit and optocouplers (service manual p. 48)
The protection loop in Amstrad's schematic (p. 48): IC602 MB3761 and Q601 on the primary side, the regulation optocoupler Q602 TLP732 and the protection-sense optocoupler Q603 TLP741G across the hot/cold boundary

The secondary side reports to the primary through two optocouplers: Q602 (TLP732), labelled "regulator", carries the error amplifier's feedback, and Q603 (TLP741G), labelled "protect sens", carries the protection signal. On the primary side the protection IC IC602 (MB3761) drives Q601, whose collector goes to IC601.[2] Amstrad prints these normal-running voltages:[2]

Protection circuit voltages (schematic p. 48)
Point Volts Point Volts
IC602 pin 1 3.0 IC602 pin 5 0.0
IC602 pin 2 5.1 IC602 pin 6 4.2
IC602 pin 3 0.0 IC602 pin 7 5.6
IC602 pin 4 4.9 IC602 pin 8 5.0
Q601 emitter 5.0 Q601 base 4.9
Q601 collector 1.4 Q602 pin 6 5.0
Q602 pin 4 2.5 Q603 pins 4 and 6 0.3
Q603 pin 5 5.0 Q603 pin 1 (cold side) 18.4
Q603 pin 2 (cold side) 17.5
  1. Measure IC602's pins against the table. On a failed PC2286 supply, pin 1 read 0.07 V instead of 3.0 V, pin 3 read 2.4 V instead of 0 V, pin 4 read 0 V instead of 4.9 V, pin 6 read 2.4 V instead of 4.2 V and pin 7 read 0 V instead of 5.6 V; Q601's base was held at 0 V, and the owner concluded that the protection was switching the supply off through Q601. IC602's supply at pin 8 was correct at 4.9 V.[5]
  2. Check the optocouplers. In normal running Amstrad prints 18.4 V and 17.5 V on Q603's LED (pins 1 and 2), only 0.9 V across it. VintageVic, reading the schematic, explains that this is too little to light the LED, and that when the secondary protection operates it pulls pin 2 down, the LED lights and the switch on pins 4 to 6 shuts the supply down.[2][9] A faulty optocoupler was the fault on the PC2386 above, and in a video repair of a PC2286 supply that an owner pointed to on the VCF forum.[3][9] Replace Q602 and Q603 with the types in the parts list.[1]
  3. If the protection is tripping and the optocouplers are good, work back to what is tripping it on the secondary side: the +5 V and +12 V overload comparators IC605 (BA6993), set by VR606, and the over-voltage and over-temperature protection Q616 with thermistor TH602.[2]

One owner of a PC2286 supply lifted pin 2 of Q603 out of its socket so that the protection could not operate, which let him see that +5 V came up at 5.2 V while +12 V stayed below 1 V. GiGaBiTe warned that running the supply with its protection disabled risks destroying it if anything else is wrong. If you try it, keep it brief and refit Q603 before the supply goes back into use.[9]

Check the secondary regulators

[edit | edit source]
Amstrad PC2386 power supply schematic, secondary rectifiers and regulators (service manual p. 48)
The secondary side (p. 48): −12 V from IC607 and −5 V from IC606, +12 V from the series regulator Q614 controlled by IC603-2 and VR603, and +5 V from D616, C627, C628, L602 and C629, regulated through IC603-1 and VR604

The outputs are produced in different ways, so a single wrong rail points to its own circuit:[2]

Secondary rails (schematic p. 48)
Rail How it is made Printed voltages
+5 V Rectifier D616, C627 and C628 (6800 µF 16 V), L602 and C629 (1000 µF 16 V); error amplifier IC603-1 with VR604 (+5 V ADJ) 5.2 V at the rectifier; 3.3 V at IC603 pins 5 and 6
+12 V Rectifier D614 and C625 (3300 µF 35 V), then series regulator Q614 driven by Q615 and error amplifier IC603-2 with VR603 (+12 V ADJ) 19.4 V before Q614, 12.1 V after; 3.3 V at IC603 pins 2 and 3
−12 V Rectifier D612, C623 (330 µF 63 V), regulator IC607 (AN7912T) −19.7 V in, −12.0 V out
−5 V Regulator IC606 (AN7905F), fed from the −12 V output −12.0 V in, −5 V out
  1. Check the error amplifiers in IC603 (LA6324): Amstrad prints 18.7 V at pin 4 and 3.3 V on the inputs of both halves, pins 2 and 3 and pins 5 and 6.[2]
  2. Measure across VR603 and VR604 with the power off. On the PC2286 supply that would not start, VR603 read about 1100 kΩ and turned loosely; contact cleaner did not revive it. A new 1 kΩ trimmer did not cure that supply on its own, and the +12 V output still rose to only about 4 V when the report ends.[9] VR603, VR604 and VR606 are 1 kΩ presets.[1]
  3. If the −12 V and −5 V rails are missing, check D612, C623 and IC607 before IC606, since IC606 takes its input from IC607.[2]
  4. Suspect the transformer last. On the PC2286 supply, the −12 V winding rose briefly to about 55 V at switch-on while the +5 V and +12 V windings barely rose, and GiGaBiTe pointed out that shorted turns raise the output of the other windings and that a continuity test does not prove a transformer good.[5]

Replace parts and reassemble

[edit | edit source]
  1. Replace the failed parts with the types in the parts list, and replace leaking electrolytics from the Amstrad PC2386 Capacitor Replacement Guide (Capacitor Replacement Procedure).[1]
  2. Repair broken tracks (PCB Trace Repair).
  3. Refit the frame, the supply and its connectors.

Testing and adjustment

[edit | edit source]
Amstrad PC2386 power supply adjustment points, Fig. A (service manual p. 3)
Fig. A from Amstrad's alignment instructions (p. 3): test points A and B, VR601 (primary protection), Q603, and the presets VR606, VR604 and VR603
  1. Connect the main board and a drive, and switch on. The fan, M601 (FBM-06A12HF), should keep running.[2]
  2. Measure +5 V at test point A and set it with VR604 to 5.00 V ±0.05 V.[1]
  3. Measure +12 V at test point B and set it with VR603 to 12.00 V ±0.05 V.[1]
  4. Set the primary protection with VR601. Amstrad's instruction, as printed, is to turn VR601 "anti-counterclockwise till the protection starts to cut in" and then turn it back a little to make it inactive.[1]
  5. Check −5 V and −12 V at the main board connector CD602, whose pins are tabled below.[2]
  6. Carry out Amstrad's safety tests before the machine goes back into use.[1]
Main board connector CD602 (schematic p. 48)
Pin 1 2 3 4 5 6 7 8
Rail +5 V −5 V +5 V −12 V 0 V +12 V 0 V 0 V

An owner gives the same pinout for the PC2286's main board connector.[5] The floppy drive leads CD603 and CD604 carry +5 V and ground only; the hard disc lead CD605 and the external floppy drive lead CD606 also carry +12 V.[2]

[edit | edit source]

The PC2286 supply's ICs and electrolytic capacitor values, as read by an owner, match the PC2386 parts list, but he read the +5 V rectifier D616 as a C25P046 or C25P048, where the PC2386 list gives a 30GWJ2C42, so check the parts on your own board before ordering.[4][1] The Amstrad PC2086 supply is a different design: its parts list gives 560 Ω at R658 where the PC2286 board has 1 kΩ, and it has no IC605 or IC606.[4] See the Amstrad PC2086 Maintenance Guide for that supply.

[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 Amstrad plc, PC2386-65 Personal Computer Service Manual. Hosted as File:Amstrad PC 2386 Service Manual.pdf, described at Amstrad PC 2386 Service Manual. Notes to engineers and safety tests p. 2; alignment instructions and Fig. A p. 3; power PCB layout p. 8; electrical parts list pp. 44–45 (PCB601 MP0001 power supply PCB, part 176681; supply ICs, transistors, diodes, resistors, presets and capacitors).
  2. ↑ 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19 2.20 2.21 Amstrad plc, PC2386-65 Personal Computer Service Manual, cabinet exploded view and parts list p. 47 and power supply chassis schematic diagram p. 48. Hosted as File:Amstrad PC 2386 Service Manual pages 47-48.pdf. The schematic gives the mains input, F601 (T 4A), IC601 to IC607, Q601 to Q616, the hot and cold sides, the output connectors and the DC voltages and waveforms quoted on this page.
  3. ↑ 3.0 3.1 3.2 Audigy, "Help diagnosing fault with my childhood Amstrad PC2386/65", VOGONS, 15 November 2025. Retrieved 2026-10-25. The supply failed after storage in a loft and was repaired by replacing leaking capacitors and a faulty optocoupler; afterwards it was stable under a test load with its voltages within tolerance.
  4. ↑ 4.0 4.1 4.2 4.3 4.4 4.5 VintageVic, acgs, Scruit and others, "Amstrad PC 2286", page 1, Vintage Computer Federation Forums, April–May 2022. Retrieved 2026-10-25. A corroded PC2286 supply whose fan turned briefly and stopped, with and without a drive as load; R658 (1 kΩ) and its track broken; the owner's list of the supply's ICs (STK7458, MB3761, LA6324, BA707, BA6993, AN7905F, AN7912T) and of D616 as C25P046 or C25P048.
  5. ↑ 5.0 5.1 5.2 5.3 5.4 5.5 VintageVic, acgs and GiGaBiTe, "Amstrad PC 2286", page 3, Vintage Computer Federation Forums, June 2022. Retrieved 2026-10-25. The PC2286 supply's IC602 (MB3761) voltages measured against the expected values, the conclusion that the over-voltage protection was switching the supply off through Q601, the cold-side windings at switch-on (the −12 V and −5 V winding rising briefly to about 55 V, the +5 V and +12 V windings barely rising), the film capacitors measured, the eight-pin main board connector pinout, and GiGaBiTe on shorted transformer turns.
  6. ↑ 6.0 6.1 6.2 bcg1976, VintageVic, Scruit and ilpan, "Amstrad PC 2286", page 6, Vintage Computer Federation Forums, February–March 2024. Retrieved 2026-10-25. Two more PC2286 supplies that ran the fan for a moment and stopped, one with corrosion from its two leaking 6800 µF 16 V capacitors that was not cured by replacing all the capacitors; the PC2286 supply giving no voltages without a load.
  7. ↑ RodMerida, reply of 20 October 2023 in "Amstrad PC 2286", page 6, Vintage Computer Federation Forums. Retrieved 2026-10-25. A PC2086 that powered for half a second and shut down until the hard disc's power lead was unplugged; the fault was on the drive's circuit board.
  8. ↑ 8.0 8.1 8.2 8.3 VintageVic and GiGaBiTe, "Amstrad PC 2286", page 2, Vintage Computer Federation Forums, May–June 2022. Retrieved 2026-10-25. The STK7458, the −5 V and −12 V regulators, IC603, IC605 and Q606 replaced without effect; C625 leaking at its positive leg beside Q614; GiGaBiTe on replacing leaking capacitors before further fault-finding and on reading an ESR meter's capacitance figure; the large capacitors replaced; more than 200 V on the primary capacitor.
  9. ↑ 9.0 9.1 9.2 9.3 9.4 VintageVic, GiGaBiTe, pH1 and Ghislain, "Amstrad PC 2286", page 7, Vintage Computer Federation Forums, January–March 2025. Retrieved 2026-10-25. The supply switching itself off in a fraction of a second; Q603's LED voltage in normal running; lifting Q603 pin 2 so that the protection could not operate, after which +5 V came up at 5.2 V and +12 V stayed below 1 V; VR603 found open (about 1100 kΩ) and replaced with a 1 kΩ trimmer without curing the low +12 V; GiGaBiTe's warnings about bypassing the protection; pH1's pointer to a video repair of a PC2286 supply in which the optocouplers were at fault.