BBC Master 128 Power Supply Repair

The BBC Master 128 has an internal 35 W switch-mode power supply, and the same unit is fitted to the Master Turbo and the Master 512.[1] Acorn's service manual gives no circuit, parts list or rating for it and says only to try a replacement supply, and its repair guide for dealers says to listen for ticking and, if the supply ticks, try another one.[2][3] Repairers on stardot have since worked out which parts fail: the X2 mains suppression capacitors, the start-up capacitor, the two 180 kΩ resistors that charge it, the secondary electrolytics and, less often, the voltage reference, the crowbar thyristor and the bridge rectifier.[4][5][6] Capacitor values and a plain recap are in the BBC Master 128 Capacitor Replacement Guide.
At least two, and probably three, designs were fitted: Astec units (one numbered 13830, with the start-up capacitor on a small daughter board at right angles to the main board), a San Hua Tien unit and a unit badged Acorn, part 0831,106.[6][7][4] Their designators differ, and some have no RIFA capacitors at all. Read the numbers off your own board before ordering parts.
Symptoms
[edit | edit source]| Symptom | Cause found or suggested |
|---|---|
| Bang and white smoke from the supply, with a smell; the machine may keep running | An X2 mains suppression capacitor has failed. See the capacitor guide[8][9] |
| Supply takes several seconds or longer to start | The start-up capacitor, or one of the 180 kΩ resistors R2 and R3 that charge it. One had drifted to 275 kΩ[10][5] |
| Supply dead; one primary reservoir capacitor holds the full rectified mains after switch-off and the other reads nothing | R2 or R3 open circuit[4][11] |
| Supply ticks and the machine does not start | Start-up capacitor, then the secondary electrolytics; also the crowbar firing repeatedly, a burnt feedback resistor, or a cracked leg on the voltage reference IC1 on the daughter board[5] |
| +5 V present with nothing connected, but the supply cycles or ticks once connected to the board | The secondary (output) electrolytics[5] |
| +5 V falls steadily as the load rises (4.8 V at 200 mA, 4.1 V at 1 A in one supply) | The feedback circuit, the drive to the switching transistor, or the transistor itself, once the electrolytics are known good[6] |
| Internal fuse blows at switch-on | 1024MAK names the bridge rectifier, which normally fails short circuit[6] |
| Machine works, but there is no sound and the cassette interface is dead | −5 V missing: the −5 V output or its purple lead[12][13] |
Two things are normal. Only the +5 V output is regulated, so +12 V and −5 V read low when little current is drawn from +5 V; measure them with +5 V loaded.[11][6] And a machine that beeps with a blank screen can have a supply fault or a board fault: measure +5 V under load before suspecting the board, then follow the BBC Master 128 Troubleshooting Guide.[12] The reverse also happens: FelisSapien's Master read 4.72 V on +5 V, but it still would not start on a new Mean Well supply, and the fault was on the board.[12]
Safety
[edit | edit source]Warning: the supply runs from the mains. Its two primary reservoir capacitors are in series across the rectified mains, about 170 V each in use.[12] Three bleeder resistors in series discharge them; if one has failed open circuit, a capacitor can keep its full charge after the plug is pulled, and one repairer took a shock from a supply that should have been discharged.[4][11] Unplug the machine, discharge both capacitors through a resistor, and measure 0 V across each before touching the primary side. Never solder to the computer while it is switched on.[14] cmorley notes that probing a running supply needs a suitable setup such as an isolation transformer, and suggests a professional repairer for anyone without one.[5]
Acorn's mains plug for the Master takes a 3 A fuse to BS 1362, and the computer must be earthed.[15]
Tools and parts
[edit | edit source]| Part | Value | Notes |
|---|---|---|
| X2 capacitors C1 and C2 (Astec) | 10 nF and 100 nF, class X2, 250 V AC or more | Only RIFA paper parts normally need replacing. Check the lead pitch; one Astec type had 0.22 µF in the C1 position, and the Astec 13830 had a single 100 nF part rated 400 V DC[8][7] |
| Start-up capacitor (C9; C101 on a daughter board) | 220 µF 25 V, 105 °C | The one primary-side electrolytic that is not a reservoir. On the Astec 13830 it is on the daughter board mounted at right angles to the main board[5][6][16][7] |
| Bleeder and start-up resistors R2, R3 | 180 kΩ, 2 W or 3 W | Gary C found a 2 W part in heat-shrink at the edge of the board; 1024MAK thinks they are 3 W; dominicbeesley fitted 3 W parts and MJS high-stability metal film[11][12][10][4] |
| Primary reservoir capacitors | 2 × 100 µF, 250 V as fitted (C7 and C8 on the San Hua Tien board) | MJS fitted 400 V parts because a failed bleeder can leave the full rectified mains across one capacitor[4][12] |
| Secondary electrolytics | Three 2200 µF 16 V, one 2200 µF 25 V, one 470 µF 25 V and two 220 µF 25 V in MJS's Acorn-badged supply | Values and designators vary between designs; see the capacitor guide[4][12] |
| Test load | 12 V 21 W car bulb, or a 5 Ω 5 W resistor | The bulb draws about 1 A at 5 V and is 1024MAK's test; the resistor is on Acorn's test equipment list[12][17] |
You will also need a multimeter, preferably an ESR meter, a resistor for discharging the primary capacitors (1024MAK uses 100 Ω 1 W), and strain-relief bush pliers or long-nosed locking pliers for the grommet on the output leads.[12][18][9] See Recommended Tools.
Procedure
[edit | edit source]Remove the supply
[edit | edit source]
- Unplug the mains lead and every peripheral.[13]
- Turn the computer over, remove the four lid screws marked FIX (the rear two are longer) and lift off the lid.[13][19]
- Photograph the seven supply leads on the main board, then pull them off: three red on the terminals marked +5V, three black on 0V and one purple on −5V.[13][20]
- Remove the three screws under the case that hold the supply.[13]
- Remove the screw holding the keyboard to the supply and the screw holding the main board's back plate to the supply.[13][9]
- Lift the supply out. It can be worked out at an angle, but tricky finds it easier to remove the keyboard first (unplug its two connectors and undo the three screws at its corners) and the main board (four screws through the cartridge connectors).[9][13]
Open the supply case
[edit | edit source]
- Free the cable-tie holders from the side of the case: squeeze the two halves together with side cutters and lift the legs out of the hole.[9]
- Remove the grommet (strain-relief bush) that clamps the output leads where they leave the case. Squeeze its tab with long-nosed locking pliers and lever it out with a small flat screwdriver, or use strain-relief bush pliers.[9][18]
- Remove the auxiliary power connector from the side of the case.[20]
- Remove the two screws on the top of the case.[9][20]
- Remove the four screws that hold the circuit board to the case.[9]
- Ease the board away from the case, feeding the output leads back in through their hole as you go. Other wiring stops it opening far; tricky wedges a folded padded envelope in the gap to hold it open.[9]
- Discharge both primary reservoir capacitors through a resistor and confirm 0 V across each.[12]

To change only the X2 capacitors, station240 leaves the board in the case: cut the cable tie around the blue and brown mains wires and pull the two spade terminals off the mains switch with long-nosed pliers.[20]
The board is hard to work on. Leads are bent over on the solder side and the whole underside is flooded with solder, so mark each leg with a pencil before desoldering it.[18][9] See Through-Hole Desoldering and Capacitor Replacement Procedure.
Identify the design
[edit | edit source]
- Note the maker and any number on the board and case label.[6]
- Find the start-up capacitor. It is the primary-side electrolytic that is not one of the two large reservoir capacitors: C9 (220 µF) on most boards, C101 on boards with a daughter board.[16][5]
- Find the X2 capacitors at the mains input end of the board, near the fuse.[7]
- Find the two 180 kΩ resistors, R2 and R3, in the chain of three bleeder resistors between the primary rails.[4][11]
Start-up circuit: C9, R2 and R3
[edit | edit source]The three bleeder resistors discharge the reservoir capacitors, balance the voltage between them and charge the start-up capacitor. When the start-up capacitor reaches the switching transistor's turn-on voltage the supply starts.[11][4]
- Look for dry, cracked or distorted joints on R2, R3, the switching transistor Q2 and the transformer connections, and remake any you find.[12]
- With the supply discharged and unplugged, measure R2 and R3. Each should read 180 kΩ. They go high in value or open circuit: one had drifted to 275 kΩ, and two others were open.[12][10][4][11]
- Replace any that is out of tolerance with a 2 W or 3 W part. dominicbeesley and MJS replaced both.[11][10][4]
- Replace the start-up capacitor with a 220 µF 25 V 105 °C part, checking its polarity. 1024MAK replaces this before anything else on a supply that is slow to start, ticks or gives low output.[5][6][12]
- MJS, having found R2 open, recapped the whole supply and fitted 400 V reservoir capacitors in place of the original 250 V parts, since a failed bleeder can leave the full rectified mains across one of them.[4]
dominicbeesley's supply took about 3.5 seconds to start after he had replaced C9 and the reservoir capacitors; replacing R2 and R3, one of which had drifted to 275 kΩ, made it start at once.[10]
Ticking: output capacitors, feedback and crowbar
[edit | edit source]The supply ticks when it starts, shuts down and restarts repeatedly. The crowbar (a zener diode and thyristor across +5 V) fires if the feedback loop lets the output rise.[6][5]
- Disconnect the supply from the main board and test it with the bulb on one red and one black lead.[5][12]
- If it holds about 5 V off load but cycles or ticks with the board connected, replace the secondary electrolytics. Kepler's capacitors read correctly on a capacitance meter; 1024MAK points out that an ESR test matters more in a switch-mode supply.[5]
- If it still ticks after a recap, inspect the daughter board. somerville535's supply ticked after a full recap until he found a fractured leg on IC1, the voltage reference on the daughter board, and resoldered it.[5]
- Look for a discoloured resistor in the feedback circuit. cmorley had a supply in which a burnt feedback resistor kept firing the crowbar.[5]
- Check the crowbar thyristor, which can fail short circuit, the TL431-type voltage reference and the single switching transistor Q2, often a Hitachi 2SC2928 in a TO-3 case. See Testing Diodes, Transistors and Regulators.[6][12]
Fuse blows, or the output sags under load
[edit | edit source]- If the fuse blows at switch-on, test the bridge rectifier with the meter's diode range before fitting a new fuse; 1024MAK says these normally fail short circuit. See Fuse Identification and Replacement and Finding Short Circuits.[6]
- If +5 V falls steadily as the load rises and the electrolytics, especially the start-up capacitor, are known good, the fault is in the feedback circuit, the supply to the switching transistor or the transistor itself.[6]
Repairers asking on stardot in 2017, 2021 and 2023 found no circuit diagram of the Master supply.[10][11][6] 1024MAK describes it as similar to the BBC Micro supply, with feedback through a TL431 reference and a separate small transformer, and Acorn's circuit for that supply is in the BBC Micro Model A/B Power Supply Repair. Use it as a guide to the topology only; the Master's designators and values are not the same.[6][4]
Reassemble
[edit | edit source]- Feed the output leads back out through their hole as the board goes back into the case. The edge of the hole is sharp; tricky suggests taping it while you work.[9]
- Refit the four board screws, the two top screws, the auxiliary connector, the grommet and the cable-tie holders.[9][20] VectorEyes could not always refit the grommet with every lead through it, and ran some leads outside it, tied to the case.[18]
- Test the supply on the bench (below) before refitting it.
- Refit the supply with the same M3 × 6 mm screws. Reconnect three red leads to +5V, three black to 0V and the purple to −5V; the supplies short-circuit if any two are reversed.[13]
Testing
[edit | edit source]
- Connect the bulb across one red and one black lead.[12][9]
- Switch on and measure +5 V across the bulb: 4.85 to 5.15 V is acceptable, and a supply that cannot hold that range on this load is faulty.[12]
- Measure the same output on the meter's AC range to look for ripple: 1024MAK takes 50 mV or less as good, while warning that cheap meters read high-frequency AC poorly. An oscilloscope is better.[12]
- Set the output with the cross-head adjuster reached through the hole in the side of the case. tricky turned his from 5.1 to 5.01 V on a 35 W halogen bulb; Retro Kit lowered one from 5.15 to 4.99 V.[9][21]
- Leave it running on the load for about ten minutes and measure again.[9]
- With the load still on +5 V, check the purple −5 V lead.[13][11]
- Refit the supply and measure +5 V once more at the main board terminals with the machine running.[9]
Replacing the supply
[edit | edit source]Where the original board is beyond repair, two replacements are documented.
- Simon Inns fits a Mean Well PT-65A three-output supply (60 W; 5 V 5.5 A, 12 V 2.5 A, −5 V 0.5 A) inside the original metal case on two 3D-printed brackets, with new mains leads, a new output loom with 6.3 mm receptacles for the main board, and a crimped housing for the auxiliary power connector under the computer. Its output connector is pin 1 +12 V, pins 2 and 3 +5 V, pins 4 and 5 ground and pin 6 −5 V. The PT-65A's adjuster is reached at an angle through the left-hand screw hole in the top of the case. Inns's article gives the full parts list and wire lengths.[1]
- LinuxJedi replaced a supply damaged by battery leakage with an ATX4C and a 90 W PicoPSU running from a 12 V input, giving 5 V at 6 A, 12 V at 5 A and −5 V from a 79M05 regulator on the −12 V line, in a 3D-printed holder.[22]
The computer's logic runs from +5 V alone; +12 V goes only to the auxiliary connector for disc drives and −5 V only to the cassette and sound circuits.[12] Any replacement must still supply all three if the auxiliary connector or those interfaces are used. The auxiliary output label photographed on one Master reads +12 V 1 A, +5 V 900 mA and −5 V 75 mA.[6]
Related pages
[edit | edit source]- BBC Master 128
- BBC Master 128 Capacitor Replacement Guide
- BBC Master 128 Troubleshooting Guide
- BBC Master 128 Maintenance Guide
- BBC Master 128 Battery Backup Circuit Repair, for leakage from the battery pack, which can reach the supply
- BBC Micro Model A/B Power Supply Repair, for Acorn's circuit of the related BBC Micro supply
- Capacitor Failure Symptoms
References
[edit | edit source]- ↑ 1.0 1.1 Simon Inns, "60W Acorn BBC Master power supply upgrade", Waiting for Friday, 4 May 2017 (retrieved 2026-10-25). The Master 128, Turbo and 512 supply is a 35 W switch-mode unit; Acorn's Master service manual has no details of it; the Model B and B+ service manuals give 5 V 3.5 A, −5 V 0.1 A and 12 V 1.25 A; Mean Well PT-65A replacement (60 W; 5 V 5.5 A, 12 V 2.5 A, −5 V 0.5 A), its output pins, 3D-printed brackets, external power connector orientation, and the output adjuster reached through the left screw hole in the top of the case. Content licensed CC BY-NC-ND 4.0: cited, not copied. Community source.
- ↑ Acorn Computers, Master Series Microcomputer Service Manual, part no. 0443,004, 7.1.1, p. 32 (PDF p. 36): no picture, no beep and the keyboard power light off means the supply is dead; "Try replacing the power supply anyway as the fuse may have blown".
- ↑ Acorn Computers, Master Series Hardware Specification, hosted as File:Acorn BBC Master Series Hardware Specification.pdf, "The Master 128 Repair Guide", PDF p. 17: "Listen to the power supply.... Is it 'ticking'? If so try another one. If not, replace anyway as the fuse may have blown."
- ↑ 4.00 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 stardot.org.uk, "BBC Master Power Supply Questions" (December 2020, retrieved 2026-10-25). MJS: Acorn-branded supply P/N 0831,106; a shock from a supposedly discharged supply; one reservoir capacitor with the full rectified mains, the other none; R2 open circuit; replaced R2 and R3 with high-stability metal film and recapped; annotated photograph of the electrolytic values, with 400 V reservoirs fitted in place of the original 250 V parts. 1024MAK: three bleeder resistors in series discharge and balance the primary capacitors and supply the start-up capacitor C9 (220 µF); R2 or R3 (180 kΩ) sometimes fail; the Master supply is similar to the BBC A/B/B+ supply. Community source.
- ↑ 5.00 5.01 5.02 5.03 5.04 5.05 5.06 5.07 5.08 5.09 5.10 5.11 5.12 stardot.org.uk, "BBC Master Power Supply Ticking" (September 2024 – January 2025, retrieved 2026-10-25). 1024MAK: replace the start-up capacitor C9 (normally 220 µF) first with a 105 °C part, as it causes low outputs, slow start and unstable outputs, then the secondary capacitors; ESR matters more than capacitance. cmorley: a cooked feedback resistor kept firing the crowbar; probing a running supply needs an isolation transformer. Ukwebb: a supply that holds 5 V unloaded but bounces when connected needs its output capacitors. somerville535: ticking after a full recap cured by resoldering a fractured leg on IC1, the voltage reference on the daughter board. Community source.
- ↑ 6.00 6.01 6.02 6.03 6.04 6.05 6.06 6.07 6.08 6.09 6.10 6.11 6.12 6.13 6.14 stardot.org.uk, "Master PSU variants" (July–August 2023, retrieved 2026-10-25). vexorg: photographs of a Master supply and of the computer's auxiliary power output label (+12 VDC 1 A, +5 VDC 900 mA, −5 VDC 75 mA); fuse blowing after a recap; diode readings of about 0.2 V; +5 V falling to 4.8 V at 200 mA and 4.1 V at 1 A. 1024MAK: at least two, probably three designs; the bridge rectifier may fail, normally short circuit; a minimum load affects only the unregulated +12 V and −5 V; the BBC Micro design uses a TL431 reference and a separate feedback transformer; a zener and SCR crowbar +5 V and the SCR sometimes fails short; one switching transistor; a load-dependent fall points to the feedback circuit, the transistor's supply or the transistor, assuming the electrolytics and the start-up capacitor (220 µF 25 V 105 °C) are good. Community source.
- ↑ 7.0 7.1 7.2 7.3 stardot.org.uk, "How to recap Master PSU, Astec 13830" (January–February 2019, retrieved 2026-10-25). VectorEyes: Astec 13830 with the start-up capacitor (which he describes as 200 µF 10 V) on a daughter board mounted sideways, one 100 nF RIFA rated 400 V DC and no 10 nF part. 1024MAK: the X2 capacitors are at the input fuse end of the board; only RIFA-made X2 capacitors normally need replacing; replacements must be class X2, 250 V AC or more. Community source.
- ↑ 8.0 8.1 stardot.org.uk, "BBC Master 128 Astec PSU - Cap Advice" (June 2022, retrieved 2026-10-02). 1024MAK: C1 10 nF X2 and C2 100 nF X2, any reputable maker, check the lead pitch. Gelpack found 0.22 µF in the C1 position of two supplies of one Astec type. Community source.
- ↑ 9.00 9.01 9.02 9.03 9.04 9.05 9.06 9.07 9.08 9.09 9.10 9.11 9.12 9.13 9.14 9.15 stardot.org.uk, "Replacing the caps in a Master PSU" (December 2019 – January 2020, retrieved 2026-10-25). tricky's illustrated procedure: seven board connectors and three screws underneath, the screw to the keyboard and the screw to the back plate; removing the keyboard and main board first; cable-tie holders; the grommet; two screws on top; four board screws; feeding the leads; marking legs; the sharp edge of the cable hole; load test with a 12 V 35 W halogen bulb, adjusted from 5.1 V to 5.01 V with the cross-head adjuster through the hole in the side, run for ten minutes. Community source.
- ↑ 10.0 10.1 10.2 10.3 10.4 10.5 stardot.org.uk, "Master 128 PSU schematic" (September–October 2017, retrieved 2026-10-25). dominicbeesley: slow start (about 3.5 s) after replacing C9 and the reservoir capacitors; R2 and R3 found to be 180 kΩ, not 100 kΩ, one drifted to 275 kΩ; new 3 W resistors and the supply started at once. Community source.
- ↑ 11.00 11.01 11.02 11.03 11.04 11.05 11.06 11.07 11.08 11.09 stardot.org.uk, "Master PSU circuit diagram" (October 2021 – March 2022, retrieved 2026-10-25). Gary C: no circuit found; a shock from a capacitor still holding charge; the 2 W 180 kΩ resistor in heat-shrink at the edge of the board open circuit; new RIFAs and resistor and the supply worked. 1024MAK: only +5 V is regulated, so +12 V reads low when little +5 V current is drawn; three resistors in a chain across the primary rails charge the start-up capacitor until the switching transistor turns on. Community source.
- ↑ 12.00 12.01 12.02 12.03 12.04 12.05 12.06 12.07 12.08 12.09 12.10 12.11 12.12 12.13 12.14 12.15 12.16 12.17 12.18 stardot.org.uk, "Master 128 and the long slow beep of doom" (May–October 2019, retrieved 2026-10-25). 1024MAK: the 12 V 21 W bulb test (about 1 A at 5 V), 4.85–5.15 V acceptable and a supply that cannot hold it is faulty; ripple of 50 mV or less on a meter's AC range; the main logic runs from any regulated 5 V supply; +12 V only for external disc drives and −5 V only for cassette and sound; discharge the primary capacitors with a 100 Ω 1 W resistor; check joints on Q2, R2, R3 and the transformers; R2 and R3 180 kΩ ("3W I think") go high; about 170 V DC across each primary capacitor; Q2 often a Hitachi 2SC2928 in a TO-3 case; also the 431 reference and the feedback components. FelisSapien: San Hua Tien supply (194V0L6), C7 and C8 100 µF 250 V; the Master still did not start on a Mean Well replacement supply. Community source.
- ↑ 13.0 13.1 13.2 13.3 13.4 13.5 13.6 13.7 13.8 Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, 3 "Disassembly and assembly", pp. 6–7 (PDF pp. 10–11): four lid screws underneath; keyboard held by three screws to the case and one to the supply; supply connected to the main board by seven push-on connectors and held by three screws underneath, refitted with the same M3 × 6 mm screws; main board held by four screws through the cartridge connectors and one from the back plate to the supply; three red leads to +5V, three black to 0V, the purple to −5V; the supplies short-circuit if any two are reversed.
- ↑ Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, 7 "Fault finding", p. 29 (PDF p. 33): checks to make first, including the supply working and reaching the components; hints for repair: "Never solder to a computer which is switched on".
- ↑ Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, front matter, p. 2 (PDF p. 6): "The computer must be earthed"; moulded plug with a 3 A ASTA-approved BS 1362 fuse.
- ↑ 16.0 16.1 stardot.org.uk, "BBC Master PSU - No C9" (December 2020, retrieved 2026-10-02). An Astec Master supply with the start-up capacitor on a daughter board as C101 (220 µF). Community source.
- ↑ Acorn Computers, Master Series Microcomputer Service Manual, 0443,004, test equipment list in section 7, p. 30 (PDF p. 34): screwdrivers, pliers, cutters, 10 A multimeter, RGB monitor, logic probe, a 5 Ω 5 W resistor; a 100 MHz dual-beam oscilloscope, frequency counter and known good computer.
- ↑ 18.0 18.1 18.2 18.3 stardot.org.uk, "Master PSU recap" (October 2020, retrieved 2026-10-25). VectorEyes: levering out the grommet; running some leads outside it on reassembly. KenLowe: strain-relief bush pliers. philb: leads bent over on a solder-flooded underside; replaced three primary electrolytics and two X capacitors. Community source.
- ↑ Acorn Computers, Master Series Battery Unit, part no. 0443,900, issue 3, May 1993, hosted as File:Acorn BBC Master Series Battery Unit 0443,900 Issue 3.pdf: lid screws marked FIX.
- ↑ 20.0 20.1 20.2 20.3 20.4 stardot.org.uk, "BBC Master PSU caps blown" (January 2012, retrieved 2026-10-25). danielj: photograph and label the seven leads; the screw at the back right of the supply and three underneath; screws holding the board to the housing underneath and two on top; the plastic holder on the side and the auxiliary connector must come out. station240: reaching the X2 capacitors by cutting the cable tie on the mains wires and pulling the spade terminals off the switch. Community source.
- ↑ Retro Kit, "Acorn BBC Master 128" (retrieved 2026-10-25). Repair history of one Master: leaked battery pack replaced; composite video socket replaced because of a tar-like deposit; supply output reduced from 5.15 V to 4.99 V with the trimmer; the system VIA IC8 failed intermittently and was replaced in a turned-pin socket; several keyswitches replaced. Community source.
- ↑ LinuxJedi, "BBC Master 128 #2: Retro Restoration", LinuxJedi's /dev/null, 11 January 2024 (retrieved 2026-10-25). Battery leakage corroding the supply case and components; replacement with an ATX4C and a 90 W PicoPSU from 12 V (5 V 6 A, 12 V 5 A, −5 V from a 79M05 on −12 V); a single 3.6 V lithium AA with a series diode and resistor in place of the battery pack. Community source.