Amstrad PC1640 Battery Leakage Repair

The Amstrad PC1640 keeps its clock and configuration memory alive on four AA cells in a small tray under the monitor.[1][2] Cells left in the tray can leak onto the main board. On a Schneider PC 1640, the German-branded version of the machine, repaired in 2024, the electrolyte reached the processor: it took the markings off the 8086, corroded the CPU socket and the 8087 socket beside it, and the CPU later died. After the corroded CPU socket was replaced, the machine ran but printed its messages with letters missing, because address line A16 was no longer connected between the CPU and the bus gate array.[3]
Symptoms
[edit | edit source]- "Please fit new batteries" at start-up means the cells are flat or missing and the configuration has been reset to defaults.[1] Open the tray whenever this appears on a machine that has been stored, and look at the board below it.
- After a leak, the owner of the Schneider board saw errors that came and went: once the timer (IC114, an 8253) was reported faulty, and the error disappeared whenever a POST card was fitted. The timer chip tested good in another machine. The machine then died completely, and the CPU proved dead.[3]
- With a new CPU fitted, the start-up messages lost letters: "Bitte warten" ("Please wait" on the German machine) had its first letter changing to other characters, "AMSTRAD" came out as "AM TR D", and the screen of an XT-IDE card was unreadable before the machine crashed.[3]
The Amstrad PC1640 Troubleshooting Guide covers the self-test and the faults that are not leak damage.
Safety
[edit | edit source]- The PC1640 has no power supply of its own: its rails come from the monitor through the 14-way DIN cable. Unplug that cable before working on the main board, and leave the monitor closed.[1]
- AA cell electrolyte is caustic. Wear gloves and eye protection when removing leaking cells and cleaning the board; Battery Explosion, Capacitor or Corrosion Damage covers the chemistry and the clean-up.
Tools and parts
[edit | edit source]- A multimeter with a continuity range, and an oscilloscope or logic probe for the address lines.[3]
- New 40-pin sockets for IC120 and, if it is corroded, IC119.[3] Amstrad's schematic labels IC120 as the 8086-2 CPU and IC119 as the optional 8087-2 NDP; the parts list on p. 26 gives the processor as an MBL8086-2P, part 171392, but against the reference IC119.[4]
- A replacement 8086 if the original is dead. The owner's chip tester failed both replacement 8086s he bought, yet both worked in the machine.[3]
- For diagnosis: an add-in CGA card, and Ruud's Diagnostic ROM programmed as an even/odd pair, because the PC1640 has its 32 KB of ROM split across two 16 KB chips. The diagnostic ROM would not run on the internal graphics adaptor; John Elliott explains that the adaptor behaves as an EGA unless the BIOS, or a DOS utility, switches on its CGA or MDA emulation.[3]
- Thin insulated wire for a broken connection (Jumper Wire Repair).
Procedure
[edit | edit source]Remove the cells and clean
[edit | edit source]- Unplug the 14-way DIN cable and remove the cells from the tray under the monitor.[2]
- Open the case as described in the Amstrad PC1640 Maintenance Guide.
- Look at the board under the tray, and at the CPU area in the middle of the board (picture above): IC119 and IC120 are the two 40-pin sockets, one above the other, with NR104 at the corner of IC119 and the gate array IC125 below.[4][3]
- Neutralise and clean the residue as described in Battery Explosion, Capacitor or Corrosion Damage. Check the legs of every chip the electrolyte reached; on the Schneider board it had removed the printing from the CPU.[3]
Replace the sockets and check every pin
[edit | edit source]
- Replace the corroded CPU socket, IC120, and the 8087 socket, IC119, if its contacts are damaged (Through-Hole Desoldering, IC Removal and Socketing).[3] The owner's A16 fault appeared after this step, so treat every pad and track around the socket as suspect (PCB Pad Repair, Via and Through-Hole Repair).[3]
- Before fitting the CPU, check continuity from each IC120 socket pin to where the schematic sends it. The multiplexed address and data lines go to IC125 and to the same pin numbers on IC119:[4]
| Signal | IC120 and IC119 pin | IC125 pin | Signal | IC120 and IC119 pin | IC125 pin |
|---|---|---|---|---|---|
| A19 | 35 | 77 | AD7 | 9 | 11 |
| A18 | 36 | 79 | AD6 | 10 | 10 |
| A17 | 37 | 81 | AD5 | 11 | 9 |
| A16 | 38 | 83 | AD4 | 12 | 8 |
| AD15 | 39 | 3 | AD3 | 13 | 7 |
| AD14 | 2 | 2 | AD2 | 14 | 6 |
| AD13 | 3 | 82 | AD1 | 15 | 5 |
| AD12 | 4 | 80 | AD0 | 16 | 4 |
| AD11 | 5 | 78 | BHE | 34 (IC120) | 73 |
| AD10 | 6 | 76 | S2, S1, S0 | 28, 27, 26 (IC120) | 69, 68, 63 |
| AD9 | 7 | 72 | READY | 22 (IC120) | 21 |
| AD8 | 8 | 70 | RESET | 21 (IC120) | 75 |
- Check pin 40 (VCC) for +5 V and pins 1 and 20 for ground once the board is powered.[4]
- Fit the CPU and test.
Find a broken address line
[edit | edit source]If the machine now starts but loses characters or crashes, the owner's method was:
- Disable the internal adaptor and use an add-in CGA card: switch 10 on disables the internal adaptor, and switch 6 off with switch 7 on tells the BIOS that a CGA card in 80-column mode is fitted.[3][5]
- Fit Ruud's Diagnostic ROM in place of the BIOS ROMs. On the Schneider board every test passed until "Testing RAM - Address", which counted up to 640 KB, started again at 0 and then crashed with snow on the screen.[3]
- Put the oscilloscope on A16, A17, A18 and A19 in turn. On the Schneider board A17 to A19 showed activity and A16 stayed high all the time.[3] A16 to A19 reach the expansion slots through IC115, a 74LS244, which the owner suspected before he found the fault nearer the CPU.[3]
- With the power off, check continuity from IC120 pin 38 to IC125 pin 83, and to IC119 pin 38.[4] On the Schneider board the connection from the CPU to the gate array was broken.[3]
- Restore the connection with a wire link (Jumper Wire Repair, PCB Trace Repair).
modem7 explains why the machine ran at all with A16 stuck high: Ruud's Diagnostic ROM keeps its variables and stack in the unused part of the CGA card's memory at BC000–BCFFF, where A16 is already high, and stores only a few variables in low memory.[3]
Testing
[edit | edit source]- Switch on with the internal adaptor enabled again. After the A16 repair the Schneider board booted from its XT-IDE card, and both the internal graphics and the external CGA card worked.[3]
- Set the time and configuration again; a leak usually means the NVR has been reset.[1]
- Run a RAM test. LOADXTRT.COM, the loader for XTRAMTEST, runs on a PC1640 with an add-in video card: another owner ran it for 30 passes with no errors, and an undamaged PC1640 ran it for over an hour from floppy.[3]
The repaired Schneider board did not pass everything. Ruud's Diagnostic ROM still crashed at "Testing RAM - Address", which modem7 expected a PC1640 to pass, and LOADXTRT completed one or two passes and then crashed at varying addresses. Cooling the graphics memory and the CPU with a fan made no difference. On 10 December the same machine ran LOADXTRT for two hours without a fault from a bench supply through an expansion slot, and then without faults on its own monitor, with nothing changed in between, and the owner stopped there.[3][6] The eighteen MN41256 main memory chips, IC135 to IC152, were soldered to his board, which made swapping them unattractive.[4][3]
Powering the board on the bench
[edit | edit source]The owner powered the board without its monitor through an ISA prototyping card, because nothing on the main board sits between the supply input and the expansion slots. His modern supply had no −5 V output, so he added a separate converter card in another slot.[6] The 14-way DIN pinout is in the Amstrad PC1512 Power Supply Replacement guide.
Related pages
[edit | edit source]- Amstrad PC1640 · Amstrad PC1640 Troubleshooting Guide · Amstrad PC1640 Maintenance Guide · Amstrad PC1640 Capacitor Replacement Guide
- Amstrad PC1640 Service Manual
- Amstrad PC1640 Floppy Controller Error Repair · Amstrad PC1640 PC-ECD 5 V Regulator Replacement
- Battery Explosion, Capacitor or Corrosion Damage · Continuity Testing and Signal Tracing
References
[edit | edit source]- ↑ 1.0 1.1 1.2 1.3 Amstrad, PC1640 Technical Reference Manual, section 1.9 "Real Time Clock", transcribed by John Elliott: seasip.info. Retrieved 2026-10-25. Section 1.9: the HD146818 clock and NVR backed by four non-rechargeable AA cells, and the "Please fit new batteries" message when the cells are low. Section 1.21: the power connector carrying the supply from the monitor.
- ↑ 2.0 2.1 DOS Days, "Amstrad PC1512 and PC1640". Retrieved 2026-10-25. The four AA cells in a small tray underneath the monitor.
- ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 Wobblestone, modem7, Malc and JohnElliott, "Amstrad 1640 (germany: Schneider PC 1640) with battery damage, works 'a little', has address problems", Vintage Computer Federation Forums, 24 November – 3 December 2024. Retrieved 2026-10-25. The leak onto the CPU, the corroded CPU and 8087 sockets, the timer error that came and went, the dead CPU, the garbled start-up messages, Ruud's Diagnostic ROM as an even/odd pair with a CGA card and the switch settings, A16 stuck high, the broken connection from the CPU (IC120) to the bus gate array (IC125), the 74LS244 IC115 on A16 to A19, the remaining crashes in the RAM tests, and John Elliott on the internal adaptor's CGA and MDA emulation.
- ↑ 4.0 4.1 4.2 4.3 4.4 4.5 4.6 Amstrad plc, PC1640 Personal Computer, PC-MD Monochrome Display, PC-CD Colour Display, PC-ECD Enhanced Colour Display Service Manual. Hosted as File:Amstrad PC1640 Service Manual.pdf, described at Amstrad PC1640 Service Manual. Electrical parts list p. 26 (MBL8086-2P part 171392 listed at IC119; IC114 UPD8253C-2; IC115 among the DN74LS244 positions; IC125 AMS40039; IC135–152 MN41256-15); CPU board component layout p. 28; chassis schematic p. 30 (IC119 8087-2 NDP option, IC120 8086-2 CPU, NR104 2.2 kΩ, IC125 AMS bus gate array 40039 and its pin numbers).
- ↑ John Elliott, "PC1640 DIP switches", seasip.info, 12 April 2003. Retrieved 2026-10-25. SW10 disabling the internal adaptor and SW6–SW7 selecting the add-in adaptor.
- ↑ 6.0 6.1 Wobblestone, modem7 and Malc, "Amstrad 1640 (germany: Schneider PC 1640) with battery damage ...", page 2, Vintage Computer Federation Forums, 3–10 December 2024. Retrieved 2026-10-25. The later LOADXTRT runs, powering the board from a modern supply through an ISA prototyping card with a separate −5 V converter, and the owner's conclusion.