Amstrad PC1640 floppy interface components, CPU board layout (service manual p. 28)
The floppy interface corner of the PC1640 CPU board MC0040A, from Amstrad's component layout: R181 and C124 sit between IC111 and IC110, above the floppy controller IC112; IC117 drives the disk drive connector CD102, and the option links LK1 to LK3 are beside IC113

On the Amstrad PC1640, "Error: Faulty Floppy Disk Controller or Disk Drive" with a drive that works in another PC can come from a burnt-out fusible resistor on the CPU board. R181, a 5.6 Ω fuse resistor, is the only supply to IC110, a 74LS125 buffer that passes the floppy controller's interrupt to the interrupt controller. With R181 open the interrupt never arrives, the BIOS disc test fails and the machine stops before it reaches the boot prompt.[1] The procedure below follows the signal path from the drive connector back to R181, using Amstrad's schematic and a repair reported on the VCF forum in 2023, in which a faulty 100 µF capacitor, C124, on the same feed had burnt R181 out.[2]

The Amstrad PC1512 has the same parts at the same references, a 5.6 Ω fuse resistor at R181 and a 74LS125 at IC110, but no repair of this fault on a PC1512 has been reported.[3]

Symptoms

[edit | edit source]
  • After "Please wait" and a row of dots the screen shows "Error: Faulty Floppy Disk Controller or Disk Drive" and the machine goes no further. The BIOS treats the disc test as fatal, so the error stops it even with a hard disc fitted.[4][5]
  • The drive LED never lights during the self test. On a working board the LED comes on for a moment during the disc test.[6]
  • With all three option links LK1, LK2 and LK3 fitted, the same machine runs only the keyboard and disc tests, ignores a failure in either, and reaches the "Insert a SYSTEM disk" prompt; in this mode it reports 512K, which is normal.[5][7]

The same message appears for simpler faults: drive A: unpowered, set to the wrong drive select, or its ribbon cable fitted upside down (the drive LED then lights as soon as the power is applied). Rule these out first; they are in the Amstrad PC1640 Troubleshooting Guide.[4][7]

Safety

[edit | edit source]

The PC1640 has no supply of its own: its supply rails come from the monitor through the 14-way DIN cable. Unplug that cable before soldering on the CPU board. Do not open the monitor for this repair; it contains a mains switch-mode supply and a CRT (see CRT Discharge Procedure if you have to).[8]

Tools and parts

[edit | edit source]
Parts
Ref Part Notes
R181 5.6 Ω fuse resistor, Amstrad part 175089 The owner fitted a 5.1 Ω ¼ W fusible resistor[9][1][2]
C124 100 µF electrolytic Value from the owner. Amstrad's PC2086 parts list gives C124 on that board as 100 µF, 10 V or 16 V; read the voltage printed on your part[2][10]
IC110 74LS125 quad buffer (DN74LS125P, part 171385) The owner replaced it and fitted a socket, as a precaution[9][2]

Tools: a multimeter, a logic probe, a desoldering pump or braid, and jumpers or wire links for LK1–LK3 during diagnosis. The links are bare pads on many boards; the owner soldered pin headers to them so that jumpers could be fitted and removed.[7] See Logic Chip Testing and Continuity Testing and Signal Tracing for the general methods.

Procedure

[edit | edit source]

Rule out the drive and cable

[edit | edit source]
  1. Check drive A:. The PC1640 cable has no twist and is soldered to the board, so the drive must be jumpered to the first drive select (DS0 on drives marked DS0–DS3, DS1 on drives marked DS1–DS4).[4]
  2. Check that the drive is powered: the owner measured 12 V and 5 V on its power plug.[4]
  3. If possible, test the drive in another PC on a standard cable. On the board in this repair the drive worked in another machine.[4]

Follow drive select 0

[edit | edit source]
Amstrad PC1640 floppy interface schematic (service manual p. 30)
Amstrad's floppy interface schematic: DS0 leaves the gate array IC118 at pin 78 and is inverted by IC117 (74HC240 on the schematic; the parts list gives a DN74LS240P) on its way to pin 10 of the drive connector; the controller IC112's interrupt (pin 18) goes through IC110 (LS125) to become IRQ6
  1. Open the case as described in the Amstrad PC1640 Maintenance Guide and find IC117, beside the disk drive connector CD102 (picture above).[9]
  2. Put the logic probe on IC117 pin 2 and switch on. On a working board pin 2 is low and pin 18 high at "Please wait"; after about seven seconds pin 2 goes high, pin 18 goes low and the drive LED lights.[6]
  3. If pin 2 stays low and pin 18 stays high, probe pin 78 of the gate array IC118, which drives IC117 pin 2, and check continuity between the two. On the faulty board pin 78 also stayed low and the track between them was intact.[6] modem7, working from IBM's BIOS listing, explains that the self test resets the floppy controller and waits for its interrupt before it goes on to select a drive, so the next place to look is the controller's interrupt.[6]

Follow the controller's interrupt

[edit | edit source]
  1. Probe pin 1 of the floppy controller IC112 (Z765APS), its RESET input. It should go from high to low during the self test; on the faulty board it did.[6]
  2. Probe IC112 pin 18 (INT). The controller raises INT after the reset, and the BIOS's interrupt routine clears it, so on a working board it goes high and then low again. On the faulty board it went high and stayed high: the interrupt was never serviced.[6][7]
  3. Follow INT to IC110, the 74LS125. Pin 2 is the input from IC112 pin 18, pin 3 the output, IRQ6, and pin 1 the enable. On the faulty board pin 2 went high but pin 3 stayed high throughout.[7][1][9]
  4. Measure the supply on IC110 pin 14 against ground. It should read 5 V. On the faulty board it read 0 V while the far side of R181 had a steady 5 V.[1]
  5. With the power off, measure R181. Two working boards read about 5.8 Ω and about 6 Ω in circuit; the failed one read 125 Ω one way and 106 Ω the other, and its owner described it as looking unhealthy.[1]

Find what burnt R181 out

[edit | edit source]

R181 is a fusible resistor: it opens when the current through it is too high, so treat a failed one as a sign of a fault downstream.[1] On a working board the drop across R181 never rose above 0.065 V during start-up, roughly 12 mA through 5.6 Ω.[1]

  1. In this repair the owner fitted a new R181 first, and it smoked within seconds of switching on. modem7 suggested removing C124, the 100 µF noise-filter capacitor on the same feed, and checking it once it was out; with C124 removed the next new R181 survived.[2]
  2. Remove C124 before fitting the new R181, and check it on the resistance range once it is out.[2]

Repair

[edit | edit source]
  1. Desolder C124 and R181 (Through-Hole Desoldering). Take care with the pads: on a second PC1640 in the same thread two pads had rotted away and the owner had to bridge them with enamelled wire.[11] See PCB Pad Repair if one lifts.
  2. Fit a new 100 µF capacitor at C124, observing the polarity marked on the board, with the voltage rating of the original or higher (Capacitor Replacement Procedure).[2]
  3. Fit a new fusible resistor at R181. The owner used a 5.1 Ω ¼ W fusible resistor; Amstrad's part is a 5.6 Ω fuse resistor.[1][9] See Fuse Identification and Replacement.
  4. If IC110 is suspect, replace it as well; a socket makes later testing easier (IC Removal and Socketing).[2]
  5. Remove any links fitted at LK1–LK3, so that the full self test runs.[2]

Testing

[edit | edit source]
  1. Reconnect the monitor and drive, and switch on. The self test should complete, the drive LED should light during the disc test, and the machine should report 640K and ask for a system disc.[2]
  2. Measure across R181 while the machine starts: expect well under 0.1 V.[1]
  3. If the machine now runs but the screen stays blank, check the display DIP switches before anything else. After this repair the screen was blank because the switches had been knocked; setting them back for the PC-MD monitor brought the picture back.[2] The switch chart is in the Amstrad PC1640 Maintenance Guide.

If R181 and C124 are good

[edit | edit source]

The same error has other causes on this board.

  • On a second PC1640 in the same thread, the owner rebuilt corroded pads, replaced the floppy controller without effect, and then found every IRQ line measuring high. He pulled the chip he suspected and was waiting for a new 8259 (IC109) when the report ends.[11]
  • The BIOS tests the 8259 just before the disc test, and passing that test does not rule out every interrupt fault.[5][6]
[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 jarcher1701, austfox, modem7 and Malc, "Amstrad PC1640 – Faulty Floppy Disk Controller or Disk Drive", page 4, Vintage Computer Federation Forums, 19–21 November 2023. IC110 pins 1 to 3 and pin 14, R181 open with 5 V on its other side, R181 measuring about 5.8 Ω and about 6 Ω in circuit on working boards, and the voltage across it in use.
  2. ↑ 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 jarcher1701, modem7, austfox and Malc, "Amstrad PC1640 – Faulty Floppy Disk Controller or Disk Drive", page 5, Vintage Computer Federation Forums, 30 November – 6 December 2023. The replacement R181 smoking, C124 removed, the machine booting to 640K, and the blank screen cured by resetting the DIP switches.
  3. ↑ Amstrad plc, PC1512 Personal Computer, PC-MM Monochrome Monitor, PC-CM Colour Monitor Service Manual. Hosted as File:Amstrad PC1512 Service Manual.pdf. Electrical parts list pp. 18–20: R181 and IC110 (DN74LS125P, part 171385).
  4. ↑ 4.0 4.1 4.2 4.3 4.4 jarcher1701, austfox, davide78 and modem7, "Amstrad PC1640 – Faulty Floppy Disk Controller or Disk Drive", page 1, Vintage Computer Federation Forums, 24 October – 9 November 2023. The error message, the disc test being fatal, the untwisted cable soldered to the board, drive A: on the first drive select, and testing the drive in another PC.
  5. ↑ 5.0 5.1 5.2 Amstrad, PC1640 Technical Reference Manual, section 2.2, transcribed by John Elliott: seasip.info. Retrieved 2026-10-25. Section 2.2.1 (the "Please wait" message, one dot per test and the test order), 2.2.12 (interrupt controller test) and 2.2.13 (disc test: each drive is stepped to track 10); the LK1–LK3 diagnostic mode.
  6. ↑ 6.0 6.1 6.2 6.3 6.4 6.5 6.6 jarcher1701, modem7 and austfox, "Amstrad PC1640 – Faulty Floppy Disk Controller or Disk Drive", page 2, Vintage Computer Federation Forums, 10–15 November 2023. The behaviour of IC117 pins 2 and 18 and of IC112 pins 1 and 18 on a working and a faulty board, IC118 pin 78, the POST's floppy controller check, and the interrupt path through IC110 to the 8259.
  7. ↑ 7.0 7.1 7.2 7.3 7.4 jarcher1701, austfox and modem7, "Amstrad PC1640 – Faulty Floppy Disk Controller or Disk Drive", page 3, Vintage Computer Federation Forums, 15–19 November 2023. LK1–LK3 bridged reaching the prompt at 512K on a faulty and a working machine, the interrupt line staying high, IC112 pin 18 joined to IC110 pin 2.
  8. ↑ Amstrad, PC1640 Technical Reference Manual, section 1, transcribed by John Elliott: seasip.info. Retrieved 2026-10-25. Power connector and the supply from the monitor.
  9. ↑ 9.0 9.1 9.2 9.3 9.4 Amstrad plc, PC1640 Personal Computer, PC-MD Monochrome Display, PC-CD Colour Display, PC-ECD Enhanced Colour Display Service Manual. Hosted as File:Amstrad PC1640 Service Manual.pdf, described at Amstrad PC1640 Service Manual. Electrical parts list p. 26 (R181 5.6 Ω fuse, 175089; IC109 MBL8259A-2P; IC110 DN74LS125P, 171385; IC112 Z765APS; IC118 AMS40040); CPU board component layout p. 28; floppy interface schematic p. 30.
  10. ↑ Amstrad plc, PC2086 S/D/30 Personal Computer Service Manual. Hosted as File:Amstrad PC 2086 Service Manual.pdf. Electrical parts list p. 4 (C124, 100 µF).
  11. ↑ 11.0 11.1 oldskoolpulsar, reply in "Amstrad PC1640 – Faulty Floppy Disk Controller or Disk Drive", page 6, Vintage Computer Federation Forums, 4 March 2026. A second machine with the same error: rotted pads repaired with enamelled wire, the floppy controller replaced without effect, and every IRQ line measuring high.