Jump to content

Psion Workabout Pro Troubleshooting Guide

From RetroTechCollection
Psion Teklogix Workabout Pro C front (User Manual 2005)
Workabout Pro C, from the 2005 user manual.

Fault-finding for the Psion Workabout Pro. Psion Teklogix's documents give the reset levels, the meaning of the LED while charging, the battery limits and the port pinouts; they contain no fault table for the hardware, and repairs went to Psion Teklogix's service centres.[1][2] Battery care is on the Psion Workabout Pro General Maintenance page.

Switching on

[edit | edit source]

Hold ENTER/ON for at least one second and release it when the LED flashes green. To switch off, which puts the unit in suspend, press BLUE then ENTER/ON.[1]

Resets

[edit | edit source]
Resets, Windows Mobile 2003 SE models
Reset Keys, held for at least six seconds Effect
Warm reset BLUE and ENTER/ON Closes applications; unsaved data is lost; installed programs and saved data are kept
Cold reset to the BootLoader Left SCAN, BLUE and ENTER Returns to factory settings; data and settings are lost; files in flash are kept. Type 1 at the BootLoader menu to load Windows Mobile
Cold reset straight to Windows Mobile BLUE, ORANGE and ENTER As above, without the BootLoader menu

After a cold reset to the BootLoader and a restart, the unit installs a cab file of utilities, drivers and updates and then warm starts.[1] On the Windows CE .NET models the Shutdown menu offers suspend, a warm reset that keeps saved files and registry settings, and a cold reset that loses files held outside permanent memory; at the Teklogix security level it also offers a cold reset into the Bootloader.[2]

Charging and the LED

[edit | edit source]

The LED on the left side, above the BKSP key, shows the charge state when the unit is on external power. Applications can change how it behaves.[1]

LED while on external power (2005 user manual, Table 3.1)
LED Meaning Action
Solid green Charge complete None
Fast blinking green Charging, below 80 % None
Slow blinking green Charging, above 80 % None
Solid red Temperature outside the 0 to 50 °C charging range Bring the unit and pack into the charging range
Blinking red Not charging; battery fault Try another pack; stop using a pack that is hot, swollen, discoloured or smells, or that will not charge in the specified time[1]

The standard pack's maximum fast-charge time is 3 hours and the high-capacity pack's 5 hours.[1]

Power faults

[edit | edit source]
Power and battery faults
Symptom Probable cause Action
"Low battery" warning Main pack at 50 % Charge or change the pack. A "very low main battery" notice appears at about 10 %.[1]
Unit shuts down with charge left Normal: it shuts down with enough reserve to keep data for up to 72 hours Charge or change the pack.[1]
Backup battery low warning on a new unit Coin cell not yet charged Charge overnight with the main pack fitted.[1]
Data lost after a pack change Pack changed too slowly, or the backup cell was flat Change packs within 10 to 15 minutes; keep the main pack charged so the coin cell stays charged.[1]
Short run time Backlight brightness, frequent events, an aged pack Lower the backlight, which is the largest drain; packs are considered depleted after about two years.[1]
Unit flat after storage Suspend still draws current Remove the pack for storage beyond a week.[1]

Touchscreen

[edit | edit source]

If taps land in the wrong place, align the screen: Start, Settings, System tab, Screen, then Align Screen, and follow the targets.[1] A scratched or cut top sheet, or chemical damage from the substances listed on the maintenance page, is permanent.[1]

Connectors

[edit | edit source]

Power and USB come in through the LIF port on the base and through the tether port. The supply pins are:[1]

Supply pins (2005 user manual, Appendix B)
Port DC in (5 V, 3 A) USB host power out (5 V, 100 mA max) Ground
LIF 6, 7 5 1, 2, 11, 12
Tether 8, 9, 10 4 1, 16, 17, 18

Psion Teklogix's chargers, docking stations and cradles are described in chapter 9 of the manual.[1]

[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 Psion Teklogix, WORKABOUT PRO Hand-Held Computer With Windows Mobile 2003 SE User Manual, part no. 8100058.A, May 4, 2005. Hosted as File:Psion Teklogix Workabout Pro User Manual WM2003SE (May 2005).pdf. Backup battery (p. 15), switching on and off (p. 16), resets (pp. 17-18), swap time (p. 25), touchscreen alignment (pp. 36-37), the LED (pp. 37-38), low battery warnings (p. 39), product repairs (Appendix A), battery contacts, LIF and tether port pinouts (Appendix B), battery specifications (pp. 313-316).
  2. ↑ 2.0 2.1 Psion Teklogix, WORKABOUT PRO M/C Hand-Held Computer Quick Start Guide, March 11, 2004, part no. 8000025.A. Hosted as File:Psion Teklogix Workabout Pro M-C Quick Start Guide (March 2004).pdf. Windows CE .NET Shutdown menu: suspend, warm reset, cold reset and Bootloader (p. 26).