Jump to content

Tandy 1000 SX Troubleshooting Guide

From RetroTechCollection
Tandy 1000 SX 67 W power supply 8790085 schematic (Technical Reference Manual)
Schematic of the 67 W single-input supply 8790085, from Tandy's SX technical reference manual.

Fault finding on the Tandy 1000 SX starts with the 67 W power supply, for which Tandy's Tandy 1000 SX Technical Reference Manual (catalogue no. 25-1511) gives a full test procedure. The main board has fewer documented faults. The one most often reported is a failed custom "Light Blue" chip, which stops the machine after the memory count.[1][2]

[3]

Quick reference

[edit | edit source]
Symptom Check first Section
Completely dead, fan still Fuse F1, then the supply's No Output checks; disconnect the main board to separate the two Power supply
Supply output appears, then drops to zero Over-voltage crowbar: zener D11 and photothyristor PHC2 No output
Memory count, one beep, then hang Light Blue chip U51; floppy controller U37 and data separator U38 Hangs after the memory count
Memory errors at start-up DRAMs in banks 0 and 1, and the four 64K x 4 video DRAMs Memory
Several chips dead after a supply failure DRAMs, U51, U30 After a supply fault
Keyboard types only full stops Keyboard type; try a Tandy 1000 keyboard Keyboard
No video on a VGA card DIP switch S2 switch 1 Expansion cards
Hard disk controller not working IRQ setting and S2 switch 2 Expansion cards
Vented or bulging capacitor in the supply Replace the supply electrolytics Tandy 1000 SX Capacitor Replacement Guide

Power supply

[edit | edit source]

First decide whether the fault is in the supply or on the main board. Unplug the supply's DC cable from J6 on the main board, put a test load on the supply, and measure the outputs. Tandy warns that the supply must never be run without a load, or damaging oscillations may result.[3] When one owner's SX would not power on, a forum member suggested inspecting the main board for a shorted tantalum capacitor. The owner then ran the supply with nothing connected, and the fan did not turn.[4]

Tandy's test loads for the 67 W supply:[3]

Table 1, load board values (67 W)
Output Minimum load Resistor Rating Maximum load Resistor Rating
+5 V 1.25 A 4 ohms 20 W 7.0 A 0.7 ohms 60 W
+12 V 0.15 A 80 ohms 5 W 2.4 A 5 ohms 50 W
-12 V none none none 0.25 A 48 ohms 5 W

Start-up test

[edit | edit source]

With the minimum load connected, bring the input up slowly on a variable transformer while watching +5 V on a meter and an oscilloscope. The supply should start at about 40-60 V AC and regulate once the input reaches 90 V AC. On the dual-input supply 8790084, check the voltage selector jumper first; the figures for 240 V operation are 80-120 V AC to start and 180 V AC to regulate. If +5 V reaches 5 V, check the outputs against the operating characteristics in Tandy 1000 SX General Maintenance. If there is no output, work through the next section.[3]

No output

[edit | edit source]

Tandy's sequence:[3]

  1. F1 is a 3 A 250 V fuse. If it has blown, replace it, but do not apply power until the cause is found.
  2. Check the bridge rectifier D1, the switching transistor Q1 (2SC2833) and the drive transistors Q2 and Q3 for shorted junctions, and replace any that are shorted.
  3. With the loads disconnected, measure with an ohmmeter from each output to common, looking for a shorted rectifier or capacitor.
  4. To test the over-voltage protection, raise the input from zero while reading +5 V. If the output appears and then falls back to 0 V, check zener D11 and photothyristor PHC2.
  5. With a x100 probe, compare the Q1 collector and base waveforms at 90 V AC and minimum load with the manual's figures. A collector waveform like Figure 4 means a shorted part on the secondary side. For the single-input supply 8790085, Tandy's Table 2 lists the candidates as D8, D9, D10, C16, C17, C19, C20, C21, C22 and C23. The dual-input supply 8790084 numbers its capacitors differently, and its Table 2 lists D8, D9, C17, C18, C20, C21, C22 and C23.
  6. On the dual-input supply only, check resistor R26. If it is open, check D10, C24 and IC2 on the -12 V output.

An intact fuse does not clear the supply. One owner's SX supply was silent, with no visible damage and the fuse intact, but gave 0 V on both +5 V and +12 V.[5] Another found that the -12 V capacitor C23 had vented and decided to replace every capacitor in the supply.[5] On the single-input supply, C23 is one of the parts in Tandy's Table 2.

Replacing the supply

[edit | edit source]

One forum member fitted a modern supply inside the Tandy enclosure, which keeps the original power switch.[4] Another, unable to repair a Tandy 1000 supply with no +12 V output, fitted what he believed was a Mean Well RT-85B inside the old aluminium case.[6] Any replacement has to meet the loads in Table 1 and feed the 12 V fan.

Hangs after the memory count

[edit | edit source]

The symptom: the screen shows the memory size, the machine beeps once and stops. The keyboard lock lights respond for a few seconds after power-on and then stop, and the floppy drives are never accessed.[2]

In the forum case, the owner reseated every socketed chip, cleaned the pins of the 40-pin parts, replaced the DRAMs, removed all cards and tried other floppy cables and drives without success. He then bought a second SX and swapped chips between the two machines. The custom CPU support chip U51 ("Light Blue", Tandy part 8075306) was bad in both: one was completely dead, the other reproduced the memory-count-and-beep fault in a good machine. He found no easy replacement and repaired the machine with a tested second-hand main board. Another owner later replaced a dead U51 with a spare chip.[7] In 2023 another owner with the same fault asked whether anyone had found a substitute for U51; no answer is recorded in the thread.[2] Light Blue takes the 16 MHz and 28.6 MHz clocks, generates the other clocks on the board and the system reset, and produces the floppy controller's timing and chip select.[8]

Earlier in the same thread, another member suggested the FDC9216 data separator (U38). He had traced the same symptom on a Tandy 1000 in the 1980s to that chip by cooling it with freezer spray until the drive worked, and he added that an Intel 8272 is a pin-compatible substitute for the µPD765 floppy controller (U37).[2] Both U37 and U38 are socketed, so they are quick to swap before suspecting U51.[9]

After a supply fault

[edit | edit source]

A supply that loses regulation can damage the main board. In one SX, a corner had broken off the supply board and the owner believed the supply had lost +5 V regulation. The DRAMs became very hot and had to be replaced. The Light Blue chip (U51) gave no clocks or reset and was replaced with a spare, and the Big Blue video and memory chip (U30) was loading the 28 MHz master clock. A Big Blue marked 2684-0001 worked in place of the original 2684-0002; both carry Tandy part number 8040684. The machine then booted after the owner also replaced the 8088 with a NEC V20, replaced a failed video DRAM and refitted 256K DRAMs where 64K parts had been substituted.[7] After any supply failure, check the supply under load before reconnecting it, then check the main board chip by chip.

Memory

[edit | edit source]

System memory is eight 256K DRAMs at U1-U4 and U9-U12, with eight more sockets for expansion; the 128 KB shared by video and the system is four 64K x 4 DRAMs at U24, U31, U34 and U35.[9] If chips are missing, the start-up test reports RAM errors.[2] Swap suspect chips with known good ones of the same type. When Bank 1 is fitted, jumper E1-E2 has to be removed, so check it whenever the memory count is wrong.[10]

Keyboard

[edit | edit source]

One owner found that a Tandy 2000 keyboard worked for a while and then produced only full stops on an SX, and that a Tandy 1000 keyboard worked correctly. The SX needs a Tandy 1000-style keyboard.[7][11]

Expansion cards

[edit | edit source]
  • The FAQ says DIP switch 1 on the main board must be off for a VGA card.[12]
  • As shipped, the SX expects the hard disk controller on IRQ 2. A standard XT controller uses IRQ 5, which needs DIP switch 2 off.[13] IRQ 5, 6 and 7 are shared with the vertical sync, floppy controller and printer circuits until their switches are turned off.[14]
  • The FAQ reports that the SX tends to lock up often with Tandy's "286 Express" card.[15]
  • In one owner's machine, a hard card stopped the SX from powering on until it was removed.[2]

Main board supplies

[edit | edit source]

The main board makes -5 V from the -12 V rail with VR2, a 79M05 regulator.[9][16] A missing -12 V output from the supply therefore removes -5 V as well.

[edit | edit source]

References

[edit | edit source]
  1. ↑ Tandy Corporation, Tandy 1000 SX Technical Reference Manual, catalogue no. 25-1511, 1986, hosted as File:Tandy 1000 SX Technical Reference Manual (25-1511, 1986).pdf.
  2. ↑ 2.0 2.1 2.2 2.3 2.4 2.5 "Tandy 1000sx quit working.", Vintage Computer Federation forum, 2011-2023, thread.
  3. ↑ 3.0 3.1 3.2 3.3 3.4 Tandy 1000 SX Technical Reference Manual (25-1511), "1000 SX 67 Watt Single Input Power Supply" and "67 Watt Dual Input Power Supply": troubleshooting, Table 1, Table 2, parts lists.
  4. ↑ 4.0 4.1 "Tandy 1000 SX power supply help", Vintage Computer Federation forum, August 2020, thread. Posts by 1984BBS (7 and 8 August 2020) and keenerb (7 August 2020).
  5. ↑ 5.0 5.1 "Wanted: Someone to repair Tandy 1000SX power supply", Vintage Computer Federation forum, 2018-2019, thread. Posts by itsvince725 (18-19 September 2018) and seat safety switch (1 June 2019).
  6. ↑ "Restore a Tandy 1000SX", Vintage Computer Federation forum, June 2021, thread. Post by alank2, 10 June 2021.
  7. ↑ 7.0 7.1 7.2 "Tandy 1000SX "Big Blue" (U30) interchange", Vintage Computer Federation forum, 2023, thread. Posts by seat safety switch, 27 May, 1 and 6 July and 24 August 2023.
  8. ↑ Tandy 1000 SX Technical Reference Manual (25-1511), Theory of Operation, CPU control and timing chip (p. 18) and floppy disk interface.
  9. ↑ 9.0 9.1 9.2 Tandy 1000 SX Technical Reference Manual (25-1511), Main Logic T1000 SX Subassembly 8859003A parts list, pp. 49-53.
  10. ↑ Tandy 1000 SX Technical Reference Manual (25-1511), Theory of Operation, memory expansion.
  11. ↑ Jeff Hayes, "Tandy 1000-series FAQ", version 2.52, 25 October 2005, TVDog's Tandy 1000 archive (retrieved 2026-10-21). Section II.E.1.
  12. ↑ Jeff Hayes, "Tandy 1000-series FAQ", version 2.52, 25 October 2005, TVDog's Tandy 1000 archive (retrieved 2026-10-21). Section II.B.1.
  13. ↑ Hayes, "Tandy 1000-series FAQ" (2005), section II.D.1.
  14. ↑ Tandy 1000 SX Technical Reference Manual (25-1511), Theory of Operation, interrupt assignments, p. 17.
  15. ↑ Hayes, "Tandy 1000-series FAQ" (2005), section II.F.1.
  16. ↑ Tandy 1000 SX Technical Reference Manual (25-1511), main logic schematic.