Jump to content

Amstrad CTM-640 Horizontal Oscillator Repair

From RetroTechCollection
Amstrad CPC 464 with CTM 640
A CPC 464 with its CTM640 colour monitor

The horizontal (line) oscillator in the Amstrad CTM-640 is one section of IC401, an LA7800 deflection IC. Its output at pin 3 drives the transistor Q404, which drives the horizontal output transistor Q405 through the drive transformer T401; Q405 switches the line output transformer FB401.[1] If the oscillator stops there is no horizontal drive and no picture. A CTM640 repaired by SpidersWeb on the New Zealand Vintage Computer Forums in 2015 had failed this way: the oscillator section of IC401 gave no output, and C405, the 47 µF capacitor on the oscillator's supply at pin 15, had leaked. Replacing both brought the monitor back.[2] Amstrad's CPC6128 service manual lists the same IC401, C405 and R405 for the Amstrad CTM-644, with the same voltage readings.[3]

Symptoms

[edit | edit source]
  • No picture at all with the monitor switched on.[2]
  • In SpidersWeb's monitor the 5 V output to the computer was also missing, so the CPC 464's power light stayed off; it came back when the oscillator was repaired.[2]

Rule out the simple causes first. Amstrad's fault chart for a CPC 464 with no power light checks the monitor's mains fuse, then the 5 V DC on the cable to the computer, then the cable and plug; with the light on but no picture it reminds the engineer to turn the brightness up and to check the video connector.[4] The mains fuse is F501, 2 A time-lag.[5] See also the Amstrad CTM-640 Maintenance Guide and the Amstrad CPC 464 Troubleshooting Guide.

SpidersWeb took the 5 V supply to be derived from the line output transformer, which would explain why it vanished with the oscillator.[2] Amstrad's diagram shows the computer's 5 V coming instead from the regulator IC502, fed with about 18 V from the switching transformer T501.[1][5] With the 5 V missing, check IC502 (18 V in at pin 1, 5.0 V out at pin 4) as well as the horizontal stage.

Safety

[edit | edit source]

Warning: the CTM640 has mains voltage on its main board, about 100 V on the horizontal output stage, and a CRT that holds a charge after the set is unplugged.

  • The checks below are made with the monitor running and the back off. Use an isolation transformer, insulated tools and one hand, as the Amstrad CTM-640 Maintenance Guide describes.[6]
  • Unplug the monitor and discharge the CRT before soldering; see CRT Discharge Procedure.
  • SpidersWeb warns that anyone working on these monitors must know where the high voltages are before probing.[2]

Tools and parts

[edit | edit source]
Parts in the horizontal drive path[5][1]
Ref Part Amstrad part no.
IC401 LA7800 deflection IC 1400106
C405 47 µF 16 V electrolytic (same part as C418) 1400244
R405 6.8 kΩ 2 W metal oxide 170415
C401 47 µF 160 V electrolytic 170422
Q404 2SC2271 horizontal driver 170449
T401 Horizontal drive transformer 305Y001 170463
R427 3.3 kΩ 2 W metal oxide 170414
Q405 2SD1397 horizontal output 170450

SpidersWeb ordered a new LA7800 online in New Zealand and had it delivered the next day.[2]

Tools: a multimeter, an oscilloscope to see the oscillator output, a frequency counter for the hold adjustment, desoldering tools and an isolation transformer.[2][5] The general methods are on Continuity Testing and Signal Tracing, Testing Diodes, Transistors and Regulators, Through-Hole Desoldering, IC Removal and Socketing and Capacitor Replacement Procedure.

The signal path

[edit | edit source]
Amstrad CTM640 horizontal oscillator and driver circuit (service manual p. 29)
IC401 (LA7800) in Amstrad's circuit diagram: the pin 15 line fed through R405 with C405, the horizontal oscillator output at pin 3 to Q404, and T401
Amstrad CTM640 horizontal output stage (service manual p. 30)
Q405 (2SD1397) driving the line output transformer FB401, with 100 V on its collector

On Amstrad's diagram the path is:[1]

  1. The oscillator section of IC401 is powered from pin 15. The pin 15 line is fed through R405 (6.8 kΩ 2 W) from the supply node decoupled by C401 (47 µF 160 V), with C405 (47 µF 16 V) to ground. SpidersWeb notes that the IC's main supply comes from the line output transformer, so the oscillator depends on this separate feed to start.[2]
  2. The network on pin 2, which includes the hold controls VR403 (H. HOLD) and VR404 (SUB H. HOLD), sets the oscillator frequency. Pin 4 is the input to the block marked X-ray protector, which acts on the horizontal oscillator; the zener D402 is in its circuit.
  3. Pin 3, the oscillator output, drives the base of Q404 (2SC2271). Q404's collector drives the primary of T401, which is fed through R427 (3.3 kΩ 2 W).
  4. T401's secondary drives the base of Q405 (2SD1397), whose collector carries the supply to FB401 and switches it.
Amstrad's DC voltages for the horizontal stage (p. 24)[5]
Point Normal reading Point Normal reading
IC401 pin 15 (oscillator supply) 12.43 V Q404 base 0.3 V
IC401 pin 3 (oscillator output) 0.32 V Q404 collector 34.1 V
IC401 pin 4 (X-ray protector) 0 V Q405 base 0.1 V
IC401 pin 2 6.48 V Q405 collector 98.8 V
IC401 pin 16 4.11 V IC502 pin 1 (in) / pin 4 (out) 18 V / 5.0 V

Procedure

[edit | edit source]

Finding the fault

[edit | edit source]
Amstrad CTM640 main PCB, horizontal stage (service manual p. 27)
Where the parts are on the main PCB: IC401 with C405 beside it at the left, Q404, R405, T401, R427 and C419 in the middle, and Q405 at the top right
  1. Open the monitor as described in the Amstrad CTM-640 Maintenance Guide.[6]
  2. With the monitor running, measure the collector of Q405 to ground. Amstrad gives 98.8 V. SpidersWeb found the 100 V feed present but nothing switching it.[5][2]
  3. Measure IC401 pin 15. Amstrad gives 12.43 V. If it is missing or low, switch off, discharge the set, and check R405 and C405.[5][1]
  4. Measure IC401 pin 4. Amstrad gives 0 V. On the diagram this input acts on the horizontal oscillator through the X-ray protector block, so check it before condemning the oscillator.[5][1]
  5. Look at IC401 pin 3 with an oscilloscope. A running oscillator gives a pulse train at the line frequency, which Amstrad sets to 15,625 Hz. SpidersWeb had supply on pin 15 and nothing at the oscillator output.[5][2]
  6. If pin 3 is driving, follow the signal to the base and collector of Q404 (0.3 V and 34.1 V DC), through T401, to the base of Q405. Test Q404 and Q405 out of circuit if the drive stops at either.[5]
  7. Inspect C405 and the board round it. SpidersWeb's C405 had leaked, and the electrolyte had corroded the board in the way battery leakage does.[2] See Battery Explosion, Capacitor or Corrosion Damage for cleaning.

Replacing IC401 and C405

[edit | edit source]
  1. Unplug the monitor and discharge the CRT.
  2. Note the orientation of IC401 and the polarity of C405 against the board drawing.[5]
  3. Desolder C405, clean any electrolyte and corrosion from the board, and check the tracks round it for damage (PCB Trace Repair).
  4. Desolder IC401 (LA7800). SpidersWeb found the failed capacitor while removing the IC.[2]
  5. Fit the new IC401 in the same orientation, and a new 47 µF 16 V capacitor at C405 with the correct polarity.[5]

Setting up afterwards

[edit | edit source]
  1. Power the monitor with the computer connected and check for a raster. SpidersWeb's first picture after the repair was dim; he turned up the sub-brightness and then adjusted the hold controls.[2]
  2. Set the sub-brightness to Amstrad's figure: with the brightness control at maximum, adjust VR402 for 120 V at the collector of Q802 (alignment step 7).[5]
  3. Set the horizontal hold with a frequency counter connected across the CRT heater and earth: turn H. HOLD fully anticlockwise, adjust VR404 for 14,500 Hz, then VR403 for 15,625 Hz (alignment step 8).[5]
  4. Leave VR501, the 5 V setting, alone unless the 5 V across C518 is wrong; Amstrad's note says it should not be disturbed under normal conditions.[5]

Testing

[edit | edit source]
Amstrad CTM640 voltage chart (service manual p. 24)
Amstrad's CTM640 voltage chart
  • IC401 pin 15 at about 12.4 V and Q405's collector at about 99 V, as in the table above.[5]
  • A stable picture from the CPC 464, with the computer's power light on and 5 V across C518.[5][2]
  • After any repair Amstrad specifies a flash test and an insulation test between the mains lead and accessible metal; the values are in the Amstrad CTM-640 Maintenance Guide.[6]
[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.0 1.1 1.2 1.3 1.4 1.5 Amstrad Consumer Electronics plc, CPC464 Micro Computer / CTM640 Colour Monitor / GT64 Green Monitor Service Manual, pp. 29–30 "CTM640 Circuit Diagram". Hosted as File:Amstrad CPC464 Service Manual.pdf, described at Amstrad CPC 464 Service Manual. IC401 (LA7800) pins and blocks, with the X-ray protector block feeding the horizontal oscillator; R405 6.8 kΩ 2 W from the C401 supply node and C405 47 µF 16 V on the pin 15 line; hold network on pin 2 with VR403 (H. HOLD) and VR404 (SUB H. HOLD); X-ray protector input pin 4 with D402, R425 and C418; horizontal oscillator output pin 3 to Q404 (2SC2271); T401 primary fed through R427 3.3 kΩ 2 W; Q405 (2SD1397) and FB401; the 5 V regulator IC502 fed from the switching transformer T501 through D511 and Q502.
  2. ↑ 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 SpidersWeb, "Amstrad CTM-640 adventure", New Zealand Vintage Computer Forums, Repair and Restoration, 6 October 2015 (retrieved 2026-10-25). A CTM640 that no longer gave 5 V or started up; a 100 V DC feed into the line output transformer, switched by Q405; no output from the horizontal oscillator of the LA7800 although pin 15, fed from a supply that does not come from the line output transformer and filtered by C405 (47 µF), had power; IC replaced with a new 7800 ordered online; C405 found leaking with corrosion round it and replaced; afterwards the CPC 464's power light, dim dots, then the sub-brightness and hold settings adjusted; caution about the voltages inside.
  3. ↑ Amstrad Consumer Electronics plc, CPC6128 Micro Computer / CTM644 Colour Monitor / GT65 Green Monitor Service Manual, p. 27 CTM644 electrical parts list (R405 6.8 kΩ 2 W 170415; C405 47 µF 16 V 1400244) and p. 28 "CTM644 Voltages" (IC401 LA7800, Q404, Q405). Hosted as File:Amstrad CPC6128 Service Manual.pdf, described at Amstrad CPC 6128 Service Manual.
  4. ↑ Amstrad Consumer Electronics plc, CPC464 Micro Computer / CTM640 Colour Monitor / GT64 Green Monitor Service Manual, p. 9 "CPC464 Basic Hardware Analysis". Hosted as File:Amstrad CPC464 Service Manual.pdf.
  5. ↑ 5.00 5.01 5.02 5.03 5.04 5.05 5.06 5.07 5.08 5.09 5.10 5.11 5.12 5.13 5.14 5.15 5.16 Amstrad Consumer Electronics plc, CPC464 Micro Computer / CTM640 Colour Monitor / GT64 Green Monitor Service Manual, pp. 23–24: CTM640 electrical parts list (R405 6.8 kΩ 2 W 170415; R427 3.3 kΩ 2 W 170414; C401 47 µF 160 V 170422; C405 and C418 47 µF 16 V 1400244; IC401 LA7800 1400106; Q404 2SC2271 170449; Q405 2SD1397 170450; T401 H. drive 305Y001 170463; D402 zener RB11EB; F501 2 A (T)), alignment instructions (step 6, 5 V across C518 with VR501, not to be disturbed under normal conditions; step 7, 120 V at the Q802 collector with VR402; step 8, H. HOLD fully counter-clockwise, VR404 to 14,500 Hz, VR403 to 15,625 Hz, frequency counter across the CRT heater and earth) and "CTM640 Voltages". Hosted as File:Amstrad CPC464 Service Manual.pdf.
  6. ↑ 6.0 6.1 6.2 Amstrad CTM-640 Maintenance Guide, "Safety" and "Opening and supply checks".