Atari 1050 Head Stepper and Track 00 Sensor Repair

The read/write head of the Atari 1050 is moved from track to track by a four-phase stepper motor on the drive mechanism. Four lines from the 6532 PIA (U7), NS01 to NS04, drive the stepper through two driver chips, U2 and U3, and the motor's common is fed from +12 V. A track 00 sensor on the mechanism tells the floppy disk controller when the head has reached the outermost track; its signal passes through transistor Q5.[1][2] At every switch-on the drive steps the head out until the sensor sees it, and if it has stepped more than 50 tracks without finding track 00 it stops and cycles the spindle motor off and on every 2 seconds.[1] Atari's waveforms and the voltages Howard W. Sams measured on a working drive give a check for each stage of both circuits.[3][4]
Atari's manual describes the drive built with the Tandon TM50-1 mechanism.[1]
Symptoms
[edit | edit source]- The head does not step at all. At switch-on it does not move out to track 0, and the drive goes into the 2-second on-off failure cycle.[1][5]
- The head skips tracks or steps to the wrong track.[5]
- The drive fails the diagnostic diskette's track 00 test.[6]
Atari's checklist gives, for a head that will not step: the connection and polarity at J15, the stepper driver circuit (U2, U3 and U7), and the stepper motor. For a head that skips or missteps it adds a binding band, pulley or carriage, and the track 00 sensor or Q5. For a failed track 00 test it lists a defective or misadjusted sensor, a missing or wrongly set carriage stop, and Q5 or the controller U13.[5][6] A drive whose spindle motor does not turn is a different fault; see Atari 1050 Spindle Motor Control Repair.
Tools and parts
[edit | edit source]- A multimeter, an oscilloscope (Atari specifies at least 15 MHz) and Atari's 1050 diagnostic diskette FD100690, for the head step and settle test, the track 00 test and the track zero sensor calibration.[1]
- U2 and U3: Atari's parts list gives the 75478, part number FC100536; Atari's schematic and the Sams sample show the UDN5713M.[7][2][4]
- Q5: 2N4124, Atari part number FC100527. U7: 6532 PIA, C010750. U11: 74LS02, C014340.[7]
- Best Electronics lists a track 00 sensor for the Tandon mechanism (CB101148) and a complete Tandon mechanism (CB101147).[8]

How the circuits work
[edit | edit source]Stepper drive
[edit | edit source]U7 puts out the four phases on PB5, PB4, PB3 and PB2 (pins 18, 19, 21 and 22) as NS01, NS02, NS03 and NS04.[9] NS01 and NS02 enter U2 on pins 2 and 7, and NS03 and NS04 enter U3 on the same pins. Each driver switches its outputs, pins 3 and 6, to the motor on J15: U2 pin 3 to J15 pin 1 (yellow), U2 pin 6 to pin 2 (brown), U3 pin 3 to pin 3 (orange) and U3 pin 6 to pin 4 (black). J15 pins 5 and 6 (both red) are the motor's common, connected to +12 V. Both drivers take +5 V on pin 8, ground on pin 4, an enable on pin 1 from U11 pin 10 (a 74LS02), and +12 V through R56 (47 ohms, ½ W) on pin 5.[2][10]

Track 00 sensor
[edit | edit source]The sensor is an LED and a phototransistor in one part, plugged into J10 (red, blue, yellow and grey from pin 1). The LED is fed from +5 V through R57 (150 ohms) on J10 pin 1, and J10 pin 2 is ground. The phototransistor takes +5 V on J10 pin 3 and returns its current on pin 4 through R58 (100 ohms) to the base of Q5 (2N4124), with R60 (10k) from the base to ground. Q5's collector, pulled up to +5 V by R59 (3k) and filtered by C52 (0.047 µF), is the N TRACK 00 line to pin 34 of the controller U13.[2][9][10] The Sams schematic shows R58 as 10k, with 100 ohms in some versions.[4]

Procedure
[edit | edit source]Open the drive
[edit | edit source]- Open the drive and lift out the mechanism as described in Atari 1050 Power Supply Repair#Open the drive.[1]
- U7 sits under the RF shield with the other LSI chips. To reach its pins, bend up the four tabs that hold the top shield to the board and lift it off, noting where its cutouts are so that it goes back the same way.[1]
- Check that the plugs P15 (stepper) and P10 (track 00 sensor) are fully home and the right way round, by the wire colours in figure 3-1; pin 1 is marked on the board.[10][5]

Check the stepper motor
[edit | edit source]- Unplug P15. Measure from pin 5 or 6 (the red common) to each of pins 1, 2, 3 and 4. Sams gives about 33 ohms for each winding, and its schematic shows 33.0 and 33.5 ohms.[11][4]
- An open winding means a new drive mechanism.[11] Atari's remedy for a defective stepper motor is also to replace the mechanism.[5]
- Refit P15 by its colours.[10]

Check the supplies to the drivers
[edit | edit source]- Switch on. Measure P15 pins 5 and 6 for +12 V. Sams also checks for 12 V at pins 1 to 4; if it is missing at any pin, check the plug's connections.[12][11] If +12 V is missing everywhere, go to Atari 1050 Power Supply Repair.
- Measure pin 5 of U2 and U3: Atari gives +12 V DC.[3] Pin 8 of each should be at +5 V, as Sams measured.[4]
Trace the step signals
[edit | edit source]
Make the head step while you watch with the oscilloscope: switch the drive on (it steps to track 0), or run the diagnostic diskette's head step and settle test.[1]
- Look at U7 pins 18, 19, 21 and 22 (NS01 to NS04). Each should switch between 0 and 5 V in the pattern of page 4-10.[3][9] If any is missing, substitute U7.[11]
- Look at the driver inputs, U2 pins 2 and 7 and U3 pins 2 and 7, for the same signals. A signal present at U7 but missing here points to the track between them.[2] See Continuity Testing and Signal Tracing.
- Look at the driver outputs, pins 3 and 6 of U2 and U3. They should switch between 12 V and 0 V, with the spikes drawn on page 4-10.[3] An input that switches with no matching output means that driver has failed, or its enable on pin 1 is wrong; Sams's logic probe found U11 pin 10, which feeds pin 1 of both drivers, low while the drive was writing.[5][4] See Logic Chip Testing.
- If the outputs switch correctly but the head does not move, the fault is in P15, the motor or the mechanism: a binding band, pulley or head carriage. Atari replaces the mechanism for all of these.[5]
Check the track 00 signal
[edit | edit source]
- With the drive on, measure the base and collector of Q5 with the head away from track 0 and with it at track 0 (just after switch-on, or during the diagnostic diskette's track 00 test, which steps the head out to track 2 and back).[1]
- Atari's values: at track 00 the base is at about 0.8 V and the collector at 0 V; away from it the base is at 0 V and the collector at 5 V.[13] Sams measured 0 V at the base and 5.0 V at the collector with the drive writing.[4]
- If the base never rises at track 00, check that the sensor gets its supplies: +5 V on J10 pin 3, and the LED current through R57 on pin 1. Then check the sensor's adjustment (below), and replace the sensor if it still does not respond.[2][6]
- If the base rises but the collector does not fall to 0 V, replace Q5.[6][2] See Testing Diodes, Transistors and Regulators.
- If the collector switches correctly and the drive still fails the track 00 test, follow N TRACK 00 to pin 34 of U13; Atari lists U13 with Q5 for this fault.[9][6]

Adjust or replace the track 00 sensor
[edit | edit source]- Run troubleshooting option 7 on the diagnostic diskette, track zero sensor calibration. If the sensor is out, the screen shows "forward" or "backward".[14]
- Loosen the screw holding the sensor and move it the way the screen asks until it shows "sensor OK". The movement needed is small. Hold the sensor in position while you tighten the screw.[14] The Atari 1050 Maintenance Guide has more detail.
- To replace a sensor that has failed, unplug P10 from J10, fit the new sensor (Best Electronics CB101148 for the Tandon mechanism) in place of the old one, plug P10 in by its colours, and calibrate it as above.[8][10][14]
- A missing or wrongly set carriage stop also fails the track 00 test; Atari's remedy is a new mechanism.[6]
Replace a failed part
[edit | edit source]- Unplug the power pack. Desolder the part; see Through-Hole Desoldering, and IC Removal and Socketing for U2, U3 or U11.
- Fit the new part the same way round and solder it. See Through-Hole Soldering.
- Refit the RF shield with its cutouts where they were, and the mechanism with its plugs by figure 3-1.[1]
Radial alignment
[edit | edit source]If the stepper motor's screws have been loosened, the head's radial alignment has to be set again with the Dymek alignment diskette: loosen the screws, rotate the motor until the cats-eye lobes are equal, recheck the track 00 sensor, and repeat until the lobe ratio is within 80 to 100 %.[15] The full set-up is in the Atari 1050 Maintenance Guide.
Testing
[edit | edit source]- Switch on with no diskette. The head should step to track 0, and after several seconds the motor and the activity LED switch off.[1]
- Run the diagnostic diskette's automatic tests. The head step and settle test reads a sector, steps to the next track and reads another within a set time; the track 00 test steps the head out to track 2 and back and checks the sensor.[1]
- Run the 10-minute single-density burn-in to check compatibility with other drives; a failure there points to alignment.[16]
Related pages
[edit | edit source]- Atari 1050
- Atari 1050 Drive Troubleshooting
- Atari 1050 Maintenance Guide
- Atari 1050 Power Supply Repair
- Atari 1050 Spindle Motor Control Repair
- Atari 1050 SIO Port Repair
- Atari 1050 Documentation
- Floppy Drive Repair
References
[edit | edit source]- ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 Atari, Inc., 1050 Disk Drive Field Service Manual (FD100330). Stepper motor and drive mechanism p. 1-7 (PDF p. 13); test equipment, power-up test, restore check and automatic diagnostic tests pp. 2-1 to 2-4 (PDF pp. 29-32); figure 2-2 p. 2-7 (PDF p. 35); disassembly, RF shields and figure 3-1 pp. 3-1 and 3-2 (PDF pp. 41-42). Hosted here as File:Atari 1050 Disk Drive Field Service Manual.pdf.
- ↑ 2.0 2.1 2.2 2.3 2.4 2.5 2.6 Atari, 1050 Disk Drive Field Service Manual (FD100330), schematic sheet 3 of 4 (Tandon), p. 5-4 (PDF p. 65; redrawn copy PDF p. 70): U2, U3, U11, R56, J15, the track 00 sensor on J10, R57 to R60, Q5 and C52.
- ↑ 3.0 3.1 3.2 3.3 Atari, 1050 Disk Drive Field Service Manual (FD100330), p. 4-10 (PDF p. 52), stepper drive signals: NS01 to NS04, pins 3 and 6 of U2 and U3, and +12 V DC at pin 5 of U2 and U3.
- ↑ 4.0 4.1 4.2 4.3 4.4 4.5 4.6 Howard W. Sams & Co., Computerfacts CD13, Atari Model 1050 Disk Drive (1987), schematic (PDF p. 3, printed p. 2): UDN5713M drivers at U2 and U3, stepper winding resistances, supply voltages, U11 logic levels, and the track 00 detector with Q5 voltages and R58 values. Hosted here as File:Sams Computerfacts CD13 Atari 1050 Disk Drive.pdf.
- ↑ 5.0 5.1 5.2 5.3 5.4 5.5 5.6 Atari, 1050 Disk Drive Field Service Manual (FD100330), symptom checklist p. 4-2 (PDF p. 44), stepper motor problems: J15, U2, U3, U7, stepper motor, band, pulley and carriage, track 00 sensor and Q5.
- ↑ 6.0 6.1 6.2 6.3 6.4 6.5 Atari, 1050 Disk Drive Field Service Manual (FD100330), symptom checklist p. 4-3 (PDF p. 45), drive will not pass the track 00 sensor test: sensor, carriage stop, Q5 and U13.
- ↑ 7.0 7.1 Atari, 1050 Disk Drive Field Service Manual (FD100330), 1050 parts list (Tandon), p. 5-11 (PDF p. 62): U2 and U3 75478 (FC100536), Q2, Q4 and Q5 2N4124 (FC100527), U7 6532 (C010750), U11 74LS02 (C014340).
- ↑ 8.0 8.1 Best Electronics, "8-Bit Drives" catalogue page: Atari 1050 Tandon mechanism track 00 sensor CB101148 and complete Tandon mechanism CB101147. Retrieved 25 October 2026.
- ↑ 9.0 9.1 9.2 9.3 Atari, 1050 Disk Drive Field Service Manual (FD100330), schematic sheet 2 of 4 (Tandon), p. 5-3 (PDF p. 64; redrawn copy PDF p. 69): U7 port lines NS01 to NS04, and N TRACK 00 at pin 34 of U13.
- ↑ 10.0 10.1 10.2 10.3 10.4 Atari, 1050 Disk Drive Field Service Manual (FD100330), figure 3-1, p. 3-1 (PDF p. 41): wire colours of J10 and J15 from pin 1.
- ↑ 11.0 11.1 11.2 11.3 Howard W. Sams & Co., Computerfacts CD13 (1987), p. 6, Troubleshooting, "Stepping motor inoperative": 12 V at pins 1 to 6 of P15, about 33 ohms per winding, waveforms at pins 18, 19, 21 and 22 of U7, and U7 by substitution.
- ↑ Howard W. Sams & Co., Computerfacts CD13 (1987), Preliminary Service Checks (PDF p. 18), stepping motor inoperative: J15 connections, 12 V at pins 5 and 6 of P15, U7, and the track 00 sensor M5.
- ↑ Atari, 1050 Disk Drive Field Service Manual (FD100330), p. 4-11 (PDF p. 53), track 00 signal at the base and collector of Q5.
- ↑ 14.0 14.1 14.2 Atari, 1050 Disk Drive Field Service Manual (FD100330), p. 2-11 (PDF p. 39), troubleshooting option 7, track zero sensor calibration.
- ↑ Atari, 1050 Disk Drive Field Service Manual (FD100330), p. 2-5 (PDF p. 33), manual alignment tests: radial track alignment on track 16 by rotating the stepper motor.
- ↑ Atari, 1050 Disk Drive Field Service Manual (FD100330), p. 2-9 (PDF p. 37), troubleshooting option 4, single-density burn-in.