Sinclair QL Troubleshooting Guide

From RetroTechCollection

Fault diagnosis on the Sinclair QL is set out in Section 4 (Fault Diagnosis and Repair) and Appendices A to D of the Sinclair QL Service Manual, which is written at component level.[1] Repair notes from Tony Firshman of TF Services supplement it.[2]

Microdrive faults are covered on the Sinclair QL Microdrive Troubleshooting Guide.

Before you start

[edit | edit source]
  • There is no mains voltage inside the QL. The highest voltage on the board is the 44 V peak-to-peak AC feed from the external power pack.[1]
  • Use an earthed, low-power soldering iron and recognised desoldering technique; see the soldering notes in the Sinclair QL Maintenance Guide.[1]
  • Switch the QL and the monitor off before connecting or disconnecting the video lead. Unplugging the RGB connection while the machine is in use has been known to damage the ZX8301 (IC22).[3]
  • Hairline solder splatter can measure several ohms and produce very misleading symptoms. Inspect the board before chasing anything complicated.[1]
  • When testing a suspect component by substitution, fit the suspect part into a known-good machine, not the other way round, so a faulty part cannot damage a working unit.[1]
Sinclair QL circuit diagram (Issue 5)
Sinclair QL main board circuit diagram, Issue 5 (Figure 1.4 of the Service Manual). The Issue 6 diagram and both PCB component-layout drawings are also on the wiki.

Normal power-on behaviour

[edit | edit source]

At switch-on the yellow power LED lights and the machine should clear the screen and show, at bottom centre:[1]

F1...MONITOR
F2...TELEVISION
(c) 1983 Sinclair Research Ltd

Reaching this screen means most of the system is working. If it does not appear, switch off and try two or three more times: the QL can lock up on start-up and appear lifeless.[1]

If only 32 KB of the 48 KB ROM is in place, the start-up screen appears with its windows but without the F1, F2 and copyright text.[4]

Reading the start-up screen

[edit | edit source]

The Service Manual reads the power-up screen to locate the fault:[1]

Start-up screen and fault area (Section 4, paras 2.2.5 to 2.2.14)
What you see What it means Where to look
Completely blank screen Often a faulty ZX8301 IC22 is socketed, so substitute it. If there is no spare, check that the CPU clock and the RGB outputs are present
"Tweed" pattern: fine green, white, red and black dots moving quickly down the screen The RAM test has started, so the ZX8301 works and the ROM is being read and executed Start at the RAMs
Geometric pattern (for example red and green vertical bars), going no further The ZX8301 works but the ROM code is not running and RAM is not being overwritten Missing ZX8301 clock to the CPU, faulty RAM, or an absent CPU
RAM test completes, geometric pattern, then blank ROM, IPC communication or interrupt problem ROM fault; ZX8302 to IPC communication (check crystal X4 is oscillating and look for activity on IPC pins 29 and 35); or a continuous interrupt to the CPU
Random flickering patterns with "excited" beeping Faulty ROM The ROM; also check the ROM enable signal on ZX8301 pin 33
Plain white screen First part of the RAM test failed (cannot store data) RAM, or an address or data line short
Plain green screen Second part of the RAM test failed (data not retained) Refresh failure, or a short on an address or data line
Nearly white or green screen with narrow vertical stripes or a pattern of dots One bit is faulty One RAM chip or a shorted data or address line; use the probe method below
Tweed pattern after RESET that then reverts to white A failure in the second bank of RAM Second RAM bank

The manual notes that a white or green screen shows the RAMs are generally working and the machine is very close to being fully operational.[1]

Pinpointing a faulty RAM chip

[edit | edit source]

Sinclair's method when the screen shows stripes or dots:[1]

  1. Connect one end of a probe to ground.
  2. Touch the probe on the data pin of each RAM in turn and watch the screen.
  3. Shorting a data line puts a vertical black line or lines on the screen. When the black line coincides with the existing dots or stripes, you have found the chip.
  4. Because the two RAM banks share the data bus, the fault could be in either bank's device (for example IC1 or IC9). Change the one in the memory-mapped area first: IC1 in that example.

A long vertical stripe suggests a data line short; dots suggest a RAM fault.[1]

For devices that are not socketed, the manual suggests a "test IC": an IC test clip with a known-good device of the same type (a 4164 for RAM) attached, bridged across each suspect chip in turn.[1]

Firshman recommends the Minerva ROM for RAM faults: its memory test flags the first faulty address, identifying the chip. The standard QL memory test does not detect RAM errors where null bits are written.[2]

Dead machine: supply checks first

[edit | edit source]

A missing copyright screen means a fundamental failure. Check the supplies first:[1]

QL supply test points (Section 4, para 2.2.3)
Function Test point Expected
±12 V regulator input + side of D26 15.6 V AC ± 2.0 V
+5 V regulator input + side of C41 +9.0 V ± 2.0 V
+12 V regulator output + side of C38 +12.0 V DC ± 0.25 V, no discernible ripple
+5 V regulator output + side of C42 +5.0 V ± 0.15 V, no discernible ripple

The external pack supplies 9 V DC at 2 A and 44 V peak-to-peak AC. It is unregulated apart from a thyristor that limits the DC peaks, and has significant ripple. On the board, IC37 (78L12) and IC36 (79L12) give +12 V at 80 mA and −12 V at 50 mA from the AC feed, and IC35 (7805) regulates the DC feed to +5 V.[1]

  • Loss of power: check IC37 and IC36.[1]
  • Noisy power supply: change the power pack.[1]
  • +5 V low: Firshman renews the 7805 if it reads below about 4.8 V, re-greases it, and checks that the heatsink screw is tight and the whole heatsink gets hot.[2]
  • Clean the mains plug, its fuse holder and terminals, and the power pack connections. The QL's power socket often has dry joints, especially on machines used with the case off.[2]

Signals to check on a dead board

[edit | edit source]

If the supplies are good, compare these signals with a known-good board (Section 4, para 2.2.16):[1]

Signals to compare with a known-good board
Device Pins and signals
ZX8302 (IC23) 32 VSYNCH; 28 RESETOUTL; 10 PCENL; 30 and 31 XTAL; 8 DCSML; 25 CLOCK
68008 (IC18) 31 DTACK; 30 R/W; 29 DS; D0–D7 data lines; A0–A17 address lines
ZX8301 (IC22) 38 VDA; 36 TXOEL; 37 ROWL; 4 RDWL; 33 ROMOEH; 12 CSYNCL; 9 CAS0L; 10 CAS1L; 8 RASL; 40 WEL; 30 RED; 31 GREEN; 32 BLUE; 7 CLOCK

The para 2.2.16 list prints DTACK as pin 21 of IC18; paragraph 2.2.15 and the Figure 1.4 circuit diagram both give pin 31.[1]

If the machine has not started the RAM test at all, check for a regular DTACK signal on CPU pin 31; without it the RAM test can never start. Check for a short on the DTACK line, and check the ZX8301's DSMCL signal: a high level disables the ZX8301.[1]

If the fault persists, change the socketed ICs in the order IC18, IC22, IC23, IC24 and IC28, powering up after each change.[1]

RGB monitor output

[edit | edit source]

The ZX8301 generates red, green, blue, composite sync (CSYNCL) and vertical sync (VSYNCH), which run to the 8-pin DIN socket J7.[1] Certain issues of the ZX8301 are fragile, and unplugging the RGB lead while the machine is in use has been known to damage it.[3] Firshman reports that some monitors, Microvitec in particular, can cause trouble if leads are removed, perhaps through floating earths blowing the ZX8301; he switches all equipment on from one switch where possible.[2] Samsung-built QLs have diodes fitted piggyback on the ZX8301's RGB output pins.[4]

The Service Manual's fault-finding guide gives these display remedies for the monitor path:[1]

Symptom Remedy
No colour monitor output Renew IC22
Blurred picture Renew IC22
TV or monitor picture drifting, with gradual loss of colour in use Renew IC22
Erratic display after a warm-up period Check the RAMs

If the picture cuts in and out when the lead is moved, reflow the J7 joints and check the pads and tracks from J7 back towards IC22 before replacing the chip.

The monitor socket pinout

[edit | edit source]

Appendix A of the Service Manual gives Sinclair's revised wiring for the monitor socket, which it says replaces the instructions on page 31 of the Concepts section of the QL User Guide:[1]

QL monitor socket (Service Manual, Appendix A)
Pin Signal Level
1 Composite PAL 1 V peak-to-peak into 75 Ω
2 Ground
3 Composite monochrome video 1 V peak-to-peak into 75 Ω
4 Composite sync 0 to 5 V TTL, active low
5 Vertical sync 0 to 5 V TTL, active high
6 Green 0 to 5 V TTL, active high
7 Red 0 to 5 V TTL, active high
8 Blue 0 to 5 V TTL, active high

The Classic Console Upscaler Wiki's QL-to-SCART table numbers the pins from the User Guide's diagram instead (composite sync on 3, vertical sync on 4, red 6, blue 7, green 8) and warns that several conflicting QL diagrams exist.[3] Identify each signal with an oscilloscope before wiring a lead. The same source gives the series resistors needed to drive a 75 Ω RGB input: 680 Ω in each of red, green and blue, 1.2 kΩ in composite sync and 10 Ω in vertical sync. Driving a 75 Ω input directly from the TTL outputs, without them, can damage the QL.[3]

TV and composite video faults

[edit | edit source]

The RGB and sync signals also feed IC28 (MC1377P), which produces composite PAL for the internal UHF modulator M1, and are mixed in TR9 for a composite monochrome output.[1]

TV faults (Section 4, para 2.5 and fault-finding guide)
Symptom Action
No TV picture Tune the set slightly either side of the expected point; the modulator may have drifted
TV output distorted, or no TV output Renew IC35
Picture but no colour on the TV Check that crystal X3 is oscillating and look for colour modulation on the luminance signal. If chroma and luminance are both present but the TV will not lock, the crystal frequency is wrong; if there is no chroma, the chroma oscillator is not running
Chroma present, still no TV colour Changing the value of C31 slightly may restore it; check the RGB inputs to IC28, then consider renewing IC28
No colour TV output Check C35, C36, R85 and R86; check C29, R54 and the components around IC28; renew modulator M1; renew IC28
Dark TV screen Renew modulator M1
No black-and-white TV output Renew TR9
Fails colour test Renew crystal X3
Colour loss or fading Check the components around IC28; renew IC28
TV picture drifting continuously Check C23, C24 and C25

To test the modulator, remove IC28 and feed the VIDEO signal from TR9 in via R85. This gives a low-contrast black-and-white picture.[1]

Keyboard faults

[edit | edit source]

The keyboard is an 8 × 8 matrix with partial diode isolation, on a membrane connected at J11 and J12.[1]

The Service Manual says apparent major keyboard problems can come from the ZX8302 or the IPC, but are more commonly on the membrane or the connectors. If a whole row or column is dead, suspect a connector. If a pair of keys misbehaves, suspect a short between them; two dead rows also suggest a short. Check with an ohmmeter.[1]

To watch the scan, trigger a two-channel oscilloscope from one keyboard output (for example KB01) and check that the other outputs go high at successive intervals. A short shows clearly as disturbed scan timing.[1]

A common fault is a break in the membrane. A break near the connector can be cured by trimming the tail; elsewhere the membrane must be replaced.[1] If the QL locks up while an on-screen clock keeps running, or a few keys do not work, Firshman suspects the keyboard ribbons: clean the tail ends and the sockets, and cut about 5 mm off a damaged tail.[2] The symptom-to-remedy table for membrane, bubble mat and ICs is in the Sinclair QL Maintenance Guide.

Serial, network, sound, clock and joystick

[edit | edit source]
Service Manual fault-finding guide (other areas)[1]
Area Symptom Action
RS232-C / printer Fails the RS232 loopback test Check J5 and J6; renew IC25 and IC26; renew IC23; renew IC24
Network Fails the network test Check J9 and J10; check TR2 and its associated components
Sound No sound Check TR1; check R104 (post-Issue 6); renew IC24
Real-time clock Fails the real-time clock test Check R91, R80, C1 and C53
Joystick Fails the joystick test Check J3, J4 and J2
Reset Does not reset Check the reset switch and its spring
General System locks up after prolonged use Renew crystal X2
General Crashes at random intervals or after prolonged use Renew IC23; renew IC34; renew IC24

If the +12 V and −12 V rails are good but the serial ports will not transmit, Firshman fits the two 33 kΩ pull-ups from ZX8302 pins 19 and 21 to the −12 V rail (mandatory modification (g) in Appendix C), which he says very often cures it. He has also known an open network socket, its centre pin not making contact with no plug inserted, to affect the serial ports. Failing that, replace IC25 (1488) and try different ZX8302 and 1488 combinations.[2][1]

A loopback cable between J5 and J6 is a good overall system test: received RS-232 data passes through the IPC and the ZX8302 back onto the processor data bus, so if it works the whole system is very likely to be working.[1]

The IPC and the Hermes replacement

[edit | edit source]

The 8049 IPC (IC24) handles sound, serial input and keyboard input, and carries custom Sinclair firmware.[1][4] TF Services makes Hermes, a replacement IC that plugs into the 8049's socket next to Microdrive 1. It corrects faults in the original IPC code, including poor serial handshaking that can lose characters or cause a "serial overrun" curable only by switching off, key bounce, and the inability to receive at 19200 baud.[5]

Random crashes and lock-ups

[edit | edit source]

Firshman's checklist for a crashing QL:[2]

  1. Remove all expansions, external ROMs and upgrades and see whether the fault persists.
  2. Remove, clean and firmly reseat every socketed IC, and clean the ROM socket and the ROM cartridge edge connector (the latter with an eraser on the tracks). He calls this very often the cause of crashing on his machines.
  3. Check the +5 V rail and the regulator's contact with its heatsink.
  4. Check the machine is to the latest build standard (D14 or later, or flying leads over IC23).
  5. If expansions are marginal, run a thicker wire from the 5 V line at the regulator to the RAM 5 V rail (the thick track running from just above R68 and under IC7).
  6. Make sure the expansion connector pins are straight and the socket is clean.
  7. Switch all equipment on from one switch where possible.

Where a second working QL is available, swap all the socketed ICs across and then replace them one at a time.[2]

Repair notes

[edit | edit source]

The Service Manual's repair notes:[1]

  • Use recognised desoldering and heatsinking technique and a suitably earthed, low-power iron.
  • Make good contact between the IC35 regulator body and its heatsink, and apply thermal grease when renewing it.
  • Renew the modulator as a complete unit.
  • Use proper IC removal and insertion tools, and avoid handling the pins.
  • When replacing a keyboard membrane, make sure the ribbons are fully inserted and not kinked.

Quick reference

[edit | edit source]
Symptom First check
Power light on, no display Supply rails, then IC22, IC24, the RAMs, IC34, IC18, IC33 (the manual's order for a black screen)
Blank screen ZX8301 (IC22)
White or green screen RAM fault or an address or data line short; use the probe method
Stripes or dots on a white or green screen A single RAM bit; probe each RAM data pin
Flickering patterns with beeping ROM
Start-up screen with empty windows Only 32 KB of ROM present
No colour monitor output ZX8301 (IC22); the J7 joints
Lock-ups with an on-screen clock still running, or dead keys Keyboard ribbons and membrane
No outgoing RS-232 33 kΩ pull-ups to −12 V on ZX8302 pins 19 and 21
Random crashes IC sockets and the ROM edge connector; the +5 V rail
Microdrive problems See the Sinclair QL Microdrive Troubleshooting Guide
[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.20 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 1.29 1.30 1.31 1.32 1.33 Sinclair QL Service Manual (File:Sinclair QL Service Manual.pdf), Sinclair Research Ltd, prepared by Thorn (EMI) Datatech, issue 3, October 1985. Section 1 (system description), Section 4 (power-up diagnosis, supply test points, signal checks, fault-finding guide and repair notes) and Appendix A (monitor connections).
  2. ↑ 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 Firshman, Tony. "QL Troubleshooting", TF Services, last updated 28 October 2003. Source for the Minerva RAM-test advice, socket and edge-connector cleaning, the 7805 check, keyboard ribbon repair, the −12 V serial pull-ups, the power-socket and monitor-earth notes.
  3. ↑ 3.0 3.1 3.2 3.3 "Sinclair QL", Classic Console Upscaler Wiki. Source for the ZX8301 hot-unplugging warning, the series-resistor values for a 75 Ω RGB input and the video timing.
  4. ↑ 4.0 4.1 4.2 König, Urs. "Sinclair QL Build Standards", sinclairql.net. Source for the 32 KB ROM symptom and the Samsung RGB protection diodes.
  5. ↑ Firshman, Tony. "Hermes: a replacement IC for the QL's 8049 co-processor", TF Services, 26 January 2003.