Jump to content

Macintosh Centris 610 Power Supply Replacement

From RetroTechCollection
Macintosh Centris 610 power supply and power switch (Apple Service Source)
Lifting the supply out of a Centris 610. The power switch on the supply sits in the front-panel actuator. Apple Computer, Service Source.

The Macintosh Centris 610, Macintosh Quadra 610, Macintosh Quadra 610 DOS Compatible and Apple Workgroup Server 60 share one case and one power supply, Apple service part 661-1688, and Apple services them from one Service Source.[1] The Centris 610 is switched on from a separate power button on the front of the case and does not support the soft power key on the keyboard.[2] The button works the switch on the supply through a plastic actuator (part 922-0357), so the switch has to be seated in the actuator whenever the supply goes back in.[3][1] The Macintosh Centris 660AV and Macintosh Quadra 660AV use the same 661-1688 supply in the same case; their extra CD-ROM steps are given at the end.[4]

Apple's figures for the supply's rating differ: the developer note gives 86 W for the Centris 610, the Centris 610 Service Source prints 112 W not including the monitor, and the 660AV Service Source gives 86 W for the same part.[2][5][6]

Symptoms

[edit | edit source]
  • Screen completely dark, fan not running and LED not lit. Apple's cures, in order: check the external power cables, remove peripherals, replace the power supply, then replace the logic board.[7]
  • Screen dark with no sound and no drive activity, but the fan running and the LED lit. Apple lists the supply after removing cards and peripherals and trying the VRAM and DRAM SIMMs.[7]
  • The front button does nothing after the machine has been apart: check that the power switch is seated in its actuator (see Refitting the supply) before suspecting the supply.[3]
  • A supply that only needs new capacitors can be recapped; see Macintosh Centris 610 Capacitor Replacement Guide and, for the other symptoms, Macintosh Centris 610 Troubleshooting.

Safety

[edit | edit source]

Warning: the supply is mains-powered, and its reservoir capacitors keep a charge after it is unplugged. Leave the cover on the supply when swapping it as a unit; if you open it, read Working on the supply first. Apple's manual asks for anti-static precautions throughout.[3]

Tools and parts

[edit | edit source]
  • A Phillips screwdriver for the supply's retaining screw.[3]
  • A replacement supply, service part 661-1688.[1]
  • If the actuator is broken, a replacement on/off actuator, part 922-0357.[1]

Procedure

[edit | edit source]

Removing the supply

[edit | edit source]
Macintosh Centris 610 top cover removal (Apple Service Source)
Releasing the top cover tabs. Apple Computer, Service Source.
  1. Press up on the tabs at the back of the top cover, tilt the back of the cover up and remove it.[3]
Macintosh Centris 610 power supply screw (Apple Service Source)
The power supply retaining screw. Apple Computer, Service Source.
  1. Remove the screw that secures the power supply.[3]
  2. Release the floppy drive's tabs and slide the drive forward a few inches for access. If a CD-ROM drive is fitted, disconnect its SCSI data cable and move it forward as well.[3]
Macintosh Centris 610 power supply cables (Apple Service Source)
The main, hard drive and CD-ROM power cables. Apple Computer, Service Source.
  1. Disconnect the main power cable, the hard drive power cable and, if fitted, the CD-ROM drive power cable.[3]
  2. Slide the supply forward slightly.[3]
  3. Tilt the front of the supply up and lift it out of the computer.[3]

Refitting the supply

[edit | edit source]
  1. Lower the supply into place and slide it back, then reconnect the main, hard drive and CD-ROM power cables.[3]
  2. Move the floppy drive forward, then press the actuator towards the back of the computer so that the power switch on the supply seats properly in the actuator.[3]
  3. Refit the retaining screw, slide the floppy drive (and CD-ROM drive) back, reconnect the CD-ROM SCSI cable and refit the top cover.[3]

Replacing a broken actuator

[edit | edit source]
  1. The actuator only comes out once the case is stripped to the bottom cover: Apple's order is top cover, power supply, floppy drive, hard drive, CD-ROM drive, logic board and internal chassis.[3]
  2. Shift the actuator towards the back of the unit, squeeze together the tabs on its shaft and remove it.[3]
  3. Fit the new actuator and rebuild in reverse order, seating the power switch in it when the supply goes back in.[3]

Centris 660AV and Quadra 660AV

[edit | edit source]

The 660AV Service Source uses the same top cover steps and the same 661-1688 supply, with more work on the CD-ROM drive before the supply comes out.[4]

  1. After removing the supply screw and sliding the floppy drive forward, disconnect the SCSI data cable and the CD-ROM power cable from the CD-ROM drive, and disconnect the CD-ROM audio cable.[4]
  2. Remove the CD-ROM drive's EMI shield, press up on the tab and slide out the CD-ROM drive.[4]
  3. Disconnect the main power cable from the logic board and the hard drive and CD-ROM power cables, slide the supply forward slightly, tilt its front up and lift it out.[4]
  4. Apple's replacement note is the same as the Centris 610's: move the floppy drive forward and press the actuator towards the back so the power switch seats in it.[4]

Testing

[edit | edit source]
  • Press the front power button: the machine should start, the fan should run and the LED should light.[7]
  • If the button does nothing, check the switch is seated in the actuator before anything else.[3]
[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.0 1.1 1.2 1.3 Apple Computer, Macintosh Quadra 610/Centris 610/WS 60 Service Source, Exploded View (PDF p. 103): power supply 661-1688, on/off actuator 922-0357. Hosted as File:Quadra.centris_610.ws_60.pdf; see Macintosh Quadra 610/ Centris 610/WS 60 Service Source.
  2. ↑ 2.0 2.1 Apple Computer, Developer Note: Macintosh Centris 610, Macintosh Centris 650, and Macintosh Quadra 800 Computers (1993), chapter 1, "Power" and "Power Supplies", p. 9 (PDF p. 21): front power switch on the Centris 610, no keyboard soft power; Centris 610 supply 86 W. Hosted as File:Macintosh Centris 610 Centris 650 and Quadra 800 Developer Note.pdf.
  3. ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 3.14 3.15 3.16 Macintosh Quadra 610/Centris 610/WS 60 Service Source, Take Apart: Top Cover p. 1, Power Supply pp. 2-7, Bottom Cover pp. 30-31 (PDF pp. 31-37, 60-61).
  4. ↑ 4.0 4.1 4.2 4.3 4.4 4.5 Apple Computer, Centris 660AV/Quadra 660AV Service Source, Exploded View (PDF p. 97): power supply 661-1688; Take Apart, Power Supply pp. 2-10 (PDF pp. 37-45). Hosted as File:Quadra.centris_660av.pdf; see Centris 660AV/Quadra 660AV Service Source.
  5. ↑ Macintosh Quadra 610/Centris 610/WS 60 Service Source, Specifications, Electrical p. 11 (PDF p. 15).
  6. ↑ Centris 660AV/Quadra 660AV Service Source, Specifications, Electrical p. 11 (PDF p. 15).
  7. ↑ 7.0 7.1 7.2 Macintosh Quadra 610/Centris 610/WS 60 Service Source, Troubleshooting, Symptom Charts/Video pp. 2-4 (PDF pp. 20-22).