Jump to content

Apple Scanner

From RetroTechCollection
Apple Scanner
Apple Scanner with compact Macintosh
Apple Scanner beside a compact Macintosh (Wikimedia Commons, CC BY-SA 3.0)
Manufacturer Apple Computer, Inc.
Type Flatbed greyscale image scanner
Release date 1988
Interface SCSI
Compatible Macintosh computers with a SCSI port
Dimensions 545 × 340 × 110 mm
Weight 9.1 kg (20 lb)
Successor Apple OneScanner
Power 120 V AC ±10 %, 58-62 Hz (US model); 100, 120, 200, 220 or 240 V AC (universal model); 65 W maximum while scanning
Resolution 75 to 300 dpi; 16 grey levels (4 bits per pixel)

The Apple Scanner is a flatbed scanner for the Macintosh that Apple introduced in 1988. It scans documents up to 8.5 × 14 inches at up to 300 dpi, detects 16 levels of grey, and connects to the computer over SCSI.[1][2] Apple's service documents call it the 4-bit scanner, to tell it apart from the Apple OneScanner of 1991, an 8-bit model with 256 grey levels in a case that looks the same. Apple serviced both from the same manuals.[3][4]

Specifications

[edit | edit source]
Apple Scanner specifications
Item Value
Type Flatbed; the document stays still and the scanning carrier moves[3]
Maximum document 8.5 × 14 in (215.9 × 355.6 mm)[3]
Sensor CCD with 2592 elements in each of three rows[3]
Light source Green fluorescent lamp; green is the dropout colour[3][1]
Resolution 75 to 300 dpi; line art and halftone in 18 steps from 75 to 300 dpi, greyscale at 75, 100, 150, 200 or 300 dpi[3]
Grey levels 16 (4 bits per pixel)[1]
Scan time per line 5 ms line art, 8 ms halftone or greyscale, 16 ms black-and-white halftone[3]
Processor and memory NEC 7809 at 12 MHz; 32 KB ROM; 16 KB RAM (Technical Procedures) or two 16 KB banks (Tech Info Library)[3][5]
Interface SCSI; SCSI ID set by a switch, factory setting 2[6]
Power 120 V AC ±10 %, 58-62 Hz (US); 100/120/200/220/240 V AC ±10 % (universal)[3]
Power consumption Under 35 W standby, under 65 W scanning[3]
Size 545 × 340 × 110 mm (21.8 × 13.6 × 4.4 in)[1]
Weight 9.07 kg (20 lb)[3]
Operating temperature 10 to 40 °C[3]

Apple's documents disagree on a few figures. For the universal model the Technical Procedures give 58-62 Hz and the specification article 48-62 Hz. The Service Source gives the operating range as 0-40 °C and storage as −40 to 65 °C, where the Technical Procedures give 10-40 °C operating and −40 to 47 °C for six months' storage, with 65 °C allowed only in transit.[3][1][7]

How it works

[edit | edit source]
Apple Scanner major assemblies (Apple Technical Procedures)
Apple's exploded view of the scanner, showing both the 4-bit logic board and the encased 8-bit board (Technical Procedures Figure 1-1)

The scanner has five main assemblies: the scanning carrier with the optical block and fluorescent lamp, the carrier motor and belt drive, the transformer, the power supply board and the main logic board.[3]

When a scan starts, the microprocessor turns on the lamp and the carrier motor. Light reflected from the original reaches a CCD array on the CCD board in the carrier through a set of mirrors and lenses. The array is 2592 elements wide and three rows deep: the first row captures a scan line and the other two buffer it before it is shifted out, one pixel at a time, to the analogue circuitry and then to the main logic board.[3][5] On the main logic board the document-image preprocessor (DIPP) corrects distortion and digitises the signal, helped by gate array 1 (IC16), gate array 2 (IC20), a 2 KB line memory and a 2 KB picture-element correction memory. A DMA controller moves the finished image to the host over SCSI.[3]

The power circuit is a mains filter, a voltage selector on universal models, a transformer delivering 28 V AC, and a switching supply on the power supply board. The 28 V AC passes through the lid interlock switch before it reaches the supply. The supply produces +5 V for the logic, +12 V for the analogue scanning circuits, +24 V for the carrier motor and −5 V for the SCSI interface. A reset circuit built round IC1 holds the logic in reset until the +5 V rail rises above 4.75 V.[3] The carrier motor is a stepper, driven by IC5 on the power supply board from signals generated by the two gate arrays.[3]

Ports and controls

[edit | edit source]

The scanner has SCSI connectors and a SCSI ID switch, factory set to 2; Apple's instruction is not to use 7 or 8.[6] There is also an 8-pin port marked with the LocalTalk symbol and an ADB port. Apple stated that the 8-pin port was meant for connecting the scanner to a network, a feature it dropped, so the port is connected to nothing; the ADB port also has no function.[8][9] The OneScanner dropped the ADB port.[4]

A Start Scan button on the case starts a scan when the software's remote scan option is selected.[10] Holding the button while switching on runs the built-in self-test.[6]

Software

[edit | edit source]

Apple's software for the scanner was the AppleScan application and the HyperScan stack for HyperCard.[3][11] Under System 7, Apple recommended AppleScan 1.0.2 and Scanner extension 1.0.1, and said the scanner works with any Macintosh that has a SCSI port.[12] AppleScan does not run with 32-bit addressing; Apple's answer was Ofoto from Light Source, which became the OneScanner's software and was sold as an upgrade for the Apple Scanner. That matters on the Centris 660AV, Quadra 660AV and Quadra 840AV, which run only in 32-bit mode.[13] Ofoto 2.0 and Scanner driver 3.0 support both the Apple Scanner and the OneScanner.[14]

Apple published no Apple II software for the scanner, and no driver lets it work under Windows; Ofoto's Windows version supports the OneScanner only.[15][16] Everex Systems (formerly Abaton) sold an "Apple Scan Upgrade" that let the scanner deliver 256 grey levels.[17]

Logic board revisions

[edit | edit source]

The 4-bit scanner's main logic board carried three capacitors, CA4, CA5 and CA6, beside the SCSI connector CN6. They cause a SCSI timing error that can stop a Macintosh SE/30, IIx or IIcx from starting, or lock it during transfers, when other SCSI devices share the bus. Apple's fix was to remove them, which it says has no effect on scanning. A main logic board without the three capacitors is the Revision B board, service part 661-0534.[18][7] Scanner driver 2.0 also corrects the problem on faster Macintosh models.[19] The 8-bit OneScanner board is sealed in a metal shield, and Apple's instruction was to return it unopened for the modification or any repair.[18]

Service parts

[edit | edit source]
Selected Apple Scanner service parts (Service Source)
Part Apple part number
Fluorescent lamp (4-bit and 8-bit) 938-0005
Inverter assembly 076-0280
Drive belt assembly 076-0323
Carrier motor assembly 959-0037
Optical assembly, 4-bit 661-0449
Main logic board, Revision B, 4-bit 661-0534
Power supply board 661-0431
Transformer, 110 V 915-0038
Transformer, 100-240 V (universal) 915-0039
Fuses, 250 V: 1 A, 2 A, 3 A (packs of 10) 076-0284, 076-0283, 076-0285
Cover interlock switch, 110 V / 220-240 V 076-0300 / 076-0315

Part numbers from the Service Source parts list.[7] Apple's own note on the lamp is that its suppliers specified at least 200 hours of continuous use at 40 °C, and that in Apple's experience failed lamps had run more than 230 hours, roughly 2400 scans.[20]

Maintenance and repair

[edit | edit source]

Documentation

[edit | edit source]
[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.0 1.1 1.2 1.3 1.4 Apple Computer, "Apple Scanner: Specifications (Discontinued)", Tech Info Library article 3138, created 12 August 1988, reviewed 9 September 1988. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip (retrieved 2026-10-04). Source for: flatbed, 8.5 × 14 inch maximum, SCSI, green dropout colour, 20.4 seconds for an 11-inch 300 dpi line-art scan, composition types, 16 grey levels, 25 to 400 % scaling, 75 to 300 dpi, contrast, brightness, threshold and graymap settings, halftone patterns, size and weight, US and universal power input, 35 W standby and 65 W scanning, noise, temperatures.
  2. ↑ Wikipedia, "List of Apple products", https://en.wikipedia.org/wiki/List_of_Apple_products (retrieved 2026-10-04). Source for: release in August 1988.
  3. ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 Apple Computer, Apple Scanner Technical Procedures, October 1991, Section 1 Basics: product description p. 1.2, specifications pp. 1.5-1.6, theory of operation pp. 1.7-1.12, preventive maintenance p. 1.13. Hosted as File:Apple Scanner Technical Procedures (1991).pdf, PDF pp. 6-17.
  4. ↑ 4.0 4.1 Apple Computer, "Apple OneScanner: How it Differs from the Apple Scanner", Tech Info Library article 8916 (TA47301), created 1 October 1991. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip. Source for: the OneScanner looks like the Apple Scanner; 8-bit, 256 grey levels, 72 to 300 dpi in 1 dpi steps, faster, no ADB port; OneScanner software backward-compatible, with an upgrade kit for the Apple Scanner.
  5. ↑ 5.0 5.1 Apple Computer, "Apple Scanner: How Its Internal Circuitry Works", Tech Info Library article 3136 (TA38999), reviewed 12 August 1988. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip. Source for: the three rows of 2592 CCD sensors; the image-sensing and image-processing logic; the NEC 7809 at 12 MHz; the 8 MHz clock for gate array 2 and the 4 MHz clock for the DIPP, gate array 1 and the DMAC; two 16 KB RAM banks and 32 KB ROM.
  6. ↑ 6.0 6.1 6.2 Apple Computer, Apple Scanner Technical Procedures, October 1991, Section 4 Troubleshooting: self-test p. 4.2, symptom/cure chart pp. 4.3-4.4. Hosted as File:Apple Scanner Technical Procedures (1991).pdf, PDF pp. 62-64.
  7. ↑ 7.0 7.1 7.2 Apple Computer, Apple Scanners Service Source (Apple Scanner and Apple OneScanner), Service Source 2.0 CD (1996), 158 pages. Hosted as File:Apple Scanners Service Source.pdf. Specifications PDF pp. 4-8; Troubleshooting PDF pp. 10-16; Take Apart PDF pp. 18-57; Additional Procedures PDF pp. 59-74; Parts PDF pp. 76-156; Exploded View PDF pp. 157-158.
  8. ↑ Apple Computer, "Apple Scanner: 8-Pin Port Is Non-Functional", Tech Info Library article 6776 (TA45219), created 14 February 1991. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip. Source for: the 8-pin port, marked with the LocalTalk icon, was intended for networking, which was dropped; it is connected to nothing.
  9. ↑ Apple Computer, "Apple Scanner: Purpose of ADB Port", Tech Info Library article 7826 (TA46426), created 11 April 1991. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip. Source for: the ADB port has no function as of April 1991.
  10. ↑ Apple Computer, "Apple Scanner: Tips and Hints", Tech Info Library article 3499 (TA39325), reviewed 15 December 1988. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip. Source for: the 17-character limit on setting names; cut and paste in AppleScan; PICT, TIFF and Paint formats; the remote scan option and the button on the scanner.
  11. ↑ Apple Computer, "Apple Scanner: Four Must-Know Workarounds For Common Problems", Tech Info Library article 3331, reviewed 5 October 1988. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip. Source for: AppleScan and HyperScan; the 17-character limit on setting and pattern names; background printing streaks; printing half-tones; HyperScan in low memory.
  12. ↑ Apple Computer, "System 7: Upgrade Information for Apple Scanner", Tech Info Library article 7133 (TA45543), created 29 May 1991. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip. Source for: AppleScan 1.0.2 and Scanner 1.0.1 for System 7; compatibility with all Macintosh systems with SCSI.
  13. ↑ Apple Computer, "Apple Scanner: Ofoto Upgrade for 32-Bit Addressing (12/93)", Tech Info Library article 10146, created 30 April 1992, updated 23 December 1993. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip. Source for: older Apple Scanner software lacks 32-bit support; Ofoto upgrade kits from Light Source; the AV models run only in 32-bit mode.
  14. ↑ Apple Computer, "Apple Scanners: Bundled Software Compatibility (8/96)", Tech Info Library article 11139, created 12 December 1992, updated 7 August 1996. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip. Source for: Ofoto 2.0 and Scanner driver 3.0 backward compatible; the compatibility table for HyperScan 2.0.1, AppleScan 1.0.2 and Ofoto 2.0.2.
  15. ↑ Apple Computer, "Apple Scanner: No Apple II Scanner Software", Tech Info Library article 3846 (TA39935), reviewed 18 April 1989. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip.
  16. ↑ Apple Computer, "Apple Scanner: Not Compatible With the IBM PC (6/94)", Tech Info Library article 15618 (TA31919), created 15 June 1994. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip. Source for: no Windows drivers for the Apple Scanner; Ofoto for Windows supports the OneScanner.
  17. ↑ Apple Computer, "Apple Scanner: Upgrade for 256 Shades of Gray", Tech Info Library article 7049 (TA45478), created 25 February 1991, updated 15 January 1993. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip.
  18. ↑ 18.0 18.1 Apple Computer, Apple Scanner Technical Procedures, October 1991, Section 5 Additional Procedures: power supply fuses p. 5.2, main logic board fuse p. 5.3, voltage selection p. 5.4, bulb replacement pp. 5.5-5.7, voltage conversion pp. 5.8-5.9, main logic board modification pp. 5.10-5.11. Hosted as File:Apple Scanner Technical Procedures (1991).pdf, PDF pp. 66-75.
  19. ↑ Apple Computer, "Apple Scanner: Using with a Macintosh IIfx", Tech Info Library article 7771 (TA46390), created 2 July 1991, updated 22 December 1992. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip. Source for: IIfx termination rules; older scanners' extra logic board capacitors garble SCSI signals on faster Macintosh models; Scanner driver 2.0 corrects it.
  20. ↑ Apple Computer, "Apple Scanner: Bulb Life Span", Tech Info Library article 4257 (TA40223), reviewed 18 August 1989. Archive.org item APPLE_TIL_ARTICLES, file TIL00001_to_TIL60496.zip.