Silicon Graphics documents for the SGI O2: the hardware reference guide, the memory installation instructions and the site preparation guide.
O2 Workstation Hardware Reference Guide (007-3275-002)
[edit | edit source]The O2 Workstation Hardware Reference Guide is Silicon Graphics' 234-page owner's manual for the O2, document number 007-3275-002, copyright 1996, written by Judy Muchowski. This copy is SGI's electronic edition with a text layer, from the TechPubs library.[1]
Contents
[edit | edit source]| Chapter | Title | Page |
|---|---|---|
| 1 | Getting Started (setting up, O2Cam, securing the workstation, serial number) | 1 |
| 2 | Installing or Removing Memory and Option Boards (system module, DIMMs, PCI boards, display adapter, PCI tray) | 23 |
| 3 | Installing or Removing Peripherals: Internal and External Devices | 67 |
| 4 | Troubleshooting (diagnostic flow charts, power-on, confidence and IDE tests, system recovery, password jumper) | 97 |
| 5 | Ordering, Removing, and Installing Replacement Parts (system module, R5000 and R10000 CPU modules, system drive, audio-visual module, power supply, CD-ROM drive, chassis, PCI tray board) | 109 |
| 6 | Safety and Regulatory Information | 173 |
| A | Technical Specifications (connector pinouts, O2Cam, physical environment Table A-18) | 181 |
What it does not contain
[edit | edit source]There are no schematics or component lists, and no power supply ratings beyond the mains input. The physical environment table gives the case as 12 × 9 × 5 inches, which conflicts with the 11.5-inch length in SGI's site preparation guide. The clock chip is not described, though the guide does warn that the board under the PCI tray holds the system's serial number (p. 20).
Pages that cite this document
[edit | edit source]- SGI O2 – system module, power supply
- SGI O2 General Maintenance – system module, memory, CPU module and power supply procedures
- SGI O2 Troubleshooting Guide – flow charts, diagnostics, password jumper
- SGI O2 Capacitor Replacement Guide – power supply removal
Download: SGI O2 Workstation Hardware Reference Guide (007-3275-002).pdf
O2 Workstation Memory Installation Instructions (007-3778-002)
[edit | edit source]The Silicon Graphics O2 Workstation Memory Installation Instructions are a 12-page SGI leaflet, document number 007-3778-002, from 1997.[2] They cover checking for "IRIX 6.3 for O2 Including R10000" and installing the patches needed for more than 256 MB, the DIMM kits with their SGI part numbers and colour codes (16 MB to 128 MB DIMMs), the bank rules, and fitting and checking DIMMs. They contain no electrical data.
Pages that cite this document
[edit | edit source]- SGI O2 – memory kit table and bank rules
- SGI O2 General Maintenance – memory installation
- SGI O2 Troubleshooting Guide – bank rules
Download: SGI O2 Workstation Memory Installation Instructions (007-3778-002).pdf
Site preparation guide (007-3452-004)
[edit | edit source]SGI's Site Preparation for SGI 2000-Series, Origin Family, Onyx2, Octane, and O2 has a chapter on the O2 (pp. 27–32) with the chassis dimensions and weight (Table 3-1), the power and cooling figures (Table 3-2: 245 W maximum, 835 BTU per hour, 37 cfm) and the airflow path (Figure 3-2). It is hosted as File:SGI Site Preparation for SGI 2000-Series, Origin, Onyx2, Octane and O2 (007-3452-004).pdf and cited by SGI O2 and SGI O2 General Maintenance.
References
[edit | edit source]- ↑ Silicon Graphics, O2 Workstation Hardware Reference Guide, 007-3275-002, 1996, from the SGI TechPubs library mirror at techpubs.jurassic.nl.
- ↑ Silicon Graphics, Silicon Graphics O2 Workstation Memory Installation Instructions, 007-3778-002, 1997, from techpubs.jurassic.nl.