Jump to content

SGI Fuel Documentation

From RetroTechCollection
SGI Fuel rear panel (Rules666)
Rear panel of a Fuel (Rules666, CC BY-SA 4.0)

SGI Fuel Documentation describes the Silicon Graphics manuals for the Silicon Graphics Fuel hosted here, with the PDF of each. All three are SGI's own electronic editions with searchable text, taken from the Jurassic.nl mirror of SGI's TechPubs library.

Silicon Graphics Fuel Visual Workstation Hardware User's Guide (007-4480-001)

[edit | edit source]

SGI's owner's guide for the Fuel, document 007-4480-001, February 2002, 180 pages.[1]

Contents: 1 getting started (shipment, lifting, setting up); 2 using the workstation (logging in, desktop, powering off); 3 system components (enclosure, IP34 system board, processor, DIMM rules, disks, removable media, VPro graphics, PCI buses, power supply, cooling, options); 4 servicing the system (preparation and side panel removal, Table 4-1 customer-replaceable parts, DIMMs, disks, removable media, PCI boards, locks, fans and air duct, chassis feet, bezel, switch and LED assembly); 5 troubleshooting and diagnostics (environmental fault monitoring, Table 5-1 light bar signals, power-on, offline and online diagnostics); appendix A technical specifications (Table A-1 environment, Table A-2 power supply, port pinouts, serial cables, VPro ports); B safety and regulatory information, including the lithium battery statement; C internal power and SCSI cabling diagrams.[1]

The guide stops at the parts SGI allowed owners to change. It has no schematics, no component lists, and nothing on the inside of the power supply or the replacement of the system board, processor module or graphics board.[1]

Download: SGI Fuel Visual Workstation Hardware User's Guide (007-4480-001).pdf

Silicon Graphics Fuel Visual Workstation Diagnostic Reference Manual (108-0350-002)

[edit | edit source]

SGI's field-service diagnostic manual, document 108-0350-002, revision 002 of July 2002 (revised for IRIX 6.5.17 and the Internal Support Tools 2.7 CD), 234 pages. The cover marks it "SGI Confidential & Proprietary Information - For Internal Recipients Only".[2]

Contents: 1 overview, including "Before You Replace Components" (p. 1-11); 2 scan (boundary-scan) diagnostics; 3 power-on diagnostics, with Table 3-5 light bar patterns, viewing output through the L1 USB port or the internal DB-9 connector (38,400 baud), Table 3-6 virtual LED values and error messages, diag_rc values and descriptions of the IP35 PROM and base I/O tests; 4 offline (sMDK) diagnostics; 5 online diagnostics; appendix A POD mode.[2]

It contains no schematics or component data. Some procedures assume SGI's internal support tools and an L2 controller system.[2]

Download: SGI Fuel Visual Workstation Diagnostic Reference Manual (108-0350-002).pdf

Silicon Graphics Fuel Internal SCSI ID Jumper Settings (007-4565-002)

[edit | edit source]

A two-page SGI sheet, document 007-4565-002, 2002, giving the SCSI ID for each internal disk position (1, 2 and 3) and the jumper positions that set them. It notes that early Fuel disks were jumpered at the front of the drive.[3]

Download: SGI Fuel Internal SCSI ID Jumper Settings (007-4565-002).pdf

Pages that cite these documents

[edit | edit source]

References

[edit | edit source]
  1. ↑ 1.0 1.1 1.2 Silicon Graphics, Silicon Graphics Fuel Visual Workstation Hardware User's Guide, 007-4480-001, February 2002, contents and chapters 1 to 5, appendices A to C. From techpubs.jurassic.nl.
  2. ↑ 2.0 2.1 2.2 Silicon Graphics, Silicon Graphics Fuel Visual Workstation Diagnostic Reference Manual, 108-0350-002, July 2002, record of revision, contents, chapters 1 to 5 and appendix A. From techpubs.jurassic.nl/manuals/hdwr/service/.
  3. ↑ Silicon Graphics, Silicon Graphics Fuel Internal SCSI ID Jumper Settings, 007-4565-002, 2002.