SGI Onyx 3000 Capacitor Replacement Guide

Capacitor notes for the SGI Onyx 3000. SGI's owner's guide treats the power bay supplies, the bricks and the G-brick as units for its own engineers and gives no component lists or capacitor values for any of them.[1][2] No owner has published a capacitor list for an Onyx 3000 or Origin 3000 brick or power supply either. The values in your system have to be read from the parts themselves; do not fit values copied from another machine.
Warning: the power bay supplies, the G-brick supply and the D-brick supplies all run from the mains, and their input capacitors can hold a dangerous charge after the cord is pulled. SGI also warns that the brick midplanes carry voltage even when the system has been reset or halted.[1] Unplug everything, wait, and confirm with a meter that the input capacitors have discharged before working inside a supply.
Where the power is converted
[edit | edit source]| Assembly | What is documented |
|---|---|
| Power bay | Up to six supplies of 950 W each, 4.4 kW in all, with eight 48 V DC outputs; each supply has its own 200–240 V, 20 A input cord from the PDU. The bay is 3U and weighs 33 kg with six supplies. |
| Bricks fed from the power bay | C-, I-, P-, X-, N-, R- and V-bricks and the L2 controller take 48 V DC and make their own lower voltages. |
| X-brick power board | Carries the L1 controller logic, five VRMs, one DC-DC converter and three voltage regulators that convert the 48 V for the brick. |
| P-brick power board | Feeds the twelve PCI slots, on average 17.5 W (5.3 A at 3.3 V) per slot, under the control of the L1. |
| G-brick | Its own supply, 180–254 V AC, up to 2000 W, with its own cord to the wall. |
| D-brick | Two 550 W supplies, 180–254 V AC, fed from the power distribution strip. |
jan-jaap, a long-time collector, describes the brick converters as replaceable modules, not parts soldered to the boards.[5] SGI's guide does not identify the converter modules or their makers.
What owners have found
[edit | edit source]No owner reports of failed capacitors in Onyx 3000 or Origin 3000 power bay supplies, G-brick supplies or bricks have been found. The faults owners do report on these bricks are monitoring chips and L1 controllers, covered on SGI Onyx 3000 Troubleshooting Guide.[6][7] For the later Origin 350 and Onyx 350 compute modules, which use a different supply and boards, owners' repairs of regulators and supplies are on SGI Origin 350 Capacitor Replacement Guide.
Recording your own system
[edit | edit source]- Power the system down from the L2, turn off the PDU and PDS breakers and the rear switches of the G-bricks, and unplug every cord.[1]
- Photograph both sides of each board or supply before desoldering anything, with designators readable.
- For each electrolytic or polymer capacitor, write down the designator, capacitance, voltage rating, temperature rating, maker and series, size and polarity.
- Look for domed tops, leakage at the base, brown or crystalline residue and corroded traces near capacitors.
- Measure ESR with the part out of circuit and compare it with the maker's figure for that series.
| Assembly | Designator | Capacitance | Voltage | Temperature | Series | Size | Condition |
|---|---|---|---|---|---|---|---|
| Power bay supply | |||||||
| G-brick supply | |||||||
| Brick power board or converter module | |||||||
| D-brick supply |
Replacing
[edit | edit source]- Fit the same capacitance and at least the same voltage rating, with 105 °C parts, and low-ESR series wherever the original was a low-ESR type.
- Replace solid polymer parts with the same technology at an equal or lower ESR.
- Keep the original size where a heat sink or neighbouring part leaves no room for a larger one.
- Mark polarity on your photographs before removing anything.
After the repair
[edit | edit source]- Reconnect the brick or supply and power the system up from the L2.[1]
- Check the brick's rear 12 VDC and 48 VDC LEDs, and that its front panel shows no service-required or failure light.[8]
- Run
envon the brick. Every voltage should be inside its warning limits; SGI counts 10% from nominal as a warning and 20% as a fault.[9][10] - Measure the rails you worked on with a meter as well, so that a faulty monitoring chip does not mislead you.
Related pages
[edit | edit source]- SGI Onyx 3000
- SGI Onyx 3000 General Maintenance
- SGI Onyx 3000 Troubleshooting Guide
- SGI Onyx 3000 Documentation
- SGI Origin 3000
- SGI Origin 350 Capacitor Replacement Guide
- Capacitor Failure Symptoms
References
[edit | edit source]- ↑ 1.0 1.1 1.2 1.3 SGI, 007-4264-002, chapter 4, pp. 92–119. Maintenance and safety, voltage in the midplanes, powering off.
- ↑ SGI, 007-4264-002, chapter 5, pp. 121–125. Customer-replaceable units.
- ↑ Silicon Graphics, SGI Onyx 3000 Series Graphics System Hardware Owner's Guide, 007-4264-002, November 2001, chapter 1, pp. 4–5, Table 1-1 (File:SGI Onyx 3000 Series Graphics System Hardware Owner's Guide (007-4264-002).pdf). Power bay, PDU, PDS and G-brick power cables.
- ↑ SGI, 007-4264-002, appendix A, pp. 143–146, Tables A-4 to A-6. Power bay and brick power, X-brick and P-brick power boards.
- ↑ jan-jaap, reply of 17 January 2019 in "Proactive maintainability of SGI Power Supplies, thoughts?", IRIX Network forum, forums.irixnet.org.
- ↑ jan-jaap, reply of 27 September 2023 in "Origin 350 - PCI 5V missing", IRIX Network forum, forums.irixnet.org.
- ↑ jan-jaap and jpstewart, replies of 12–13 November 2020 in "CBRICK Error", IRIX Network forum, forums.irixnet.org.
- ↑ SGI, 007-4264-002, chapter 2, pp. 36–60. Brick front and rear LEDs.
- ↑ SGI, 007-4264-002, chapter 6, p. 132, Table 6-2. Voltage warning and fault thresholds.
- ↑ Silicon Graphics, SGI L1 and L2 Controller Software User's Guide, 007-3938-006, chapter 3, pp. 66–68 (File:SGI L1 and L2 Controller Software User's Guide (007-3938-006).pdf).
envcommand.