SGI Onyx 3000 General Maintenance

Routine care, power procedures and the owner-replaceable parts of the SGI Onyx 3000, from SGI's SGI Onyx 3000 Series Graphics System Hardware Owner's Guide (007-4264-002) and owners' notes. The compute and I/O bricks are shared with the SGI Origin 3000; SGI's Onyx guide covers the graphics bricks and refers to the Origin 3000 owner's guide for the rest.[1]
Safety
[edit | edit source]- The rack runs from 200–240 V AC. Turn the equipment off before connecting or disconnecting any power cord.[2]
- SGI warns that the brick midplanes carry voltage even when the system has been reset or halted.[2]
- SGI's guide says there are no user-serviceable parts inside the bricks, and limits owners to the outside of the chassis and the parts listed under owner-replaceable parts below.[2][3]
- The NUMAlink cables are made of fine copper strands, and SGI left them to its own engineers; do not kink them, and use the cable bails to hold them.[1]
- Wear an earthed wrist strap when connecting or disconnecting anything.[3]
- The I-brick motherboard has a lithium battery. SGI warns that it can explode if replaced with the wrong type.[1][4]
- Use two people to lift the 24-inch SuperWide monitors.[2] A G-brick alone weighs up to 98 kg, and a graphics rack with two G-bricks up to 386 kg.[5]
Environment
[edit | edit source]Each brick's L1 controller watches the air temperature at the brick inlet and acts at these limits:[6]
| Level | Low-altitude setting | High-altitude setting |
|---|---|---|
| Advisory | above 30 °C | above 27 °C |
| Critical | above 35 °C | above 31 °C |
| Fault (brick shuts down) | above 40 °C | above 35 °C |
The L1 env altitude high command selects the high-altitude limits for sites above 1524 m (5000 ft).[7] Air enters every brick at the front and leaves at the rear, so keep both doors clear.[8]
Powering on
[edit | edit source]Before switching on, check:[2]
- Power cables between the bricks and the power bay, the power bay and the PDU, the PDU and the PDS, and from the PDU or PDS to the wall. Each G-brick has its own cord to a wall outlet, and a D-brick plugs into the PDS.
- The outlets for the G-bricks and the PDU are fed and earthed from the same breaker box. A ground difference of more than 0.5 V between chassis joined by NUMAlink or Xtown2 cables can cause severe damage.
- The rear power switch of every brick is On (1). SGI warns that the system can malfunction or fail to boot if one is left off.
- Any D-brick has its Run/Service key switch at RUN.
Then:[2]
- Turn on the PDU and PDS circuit breakers.
- Check monitors and other peripherals for voltage select switches, set them, and plug them in.
- At the L2 touch display, choose DEST and select the racks, slots or partitions to power, or ALL.
- Press Power UP and confirm with OK.
- Check that the L1 display on each brick shows it is running.
On a system without the L2 touch display, use a terminal on the C-brick console port instead.[2] At an L2 command prompt the same is done with pwr u.[7]
Powering off
[edit | edit source]SGI recommends powering off only for maintenance or repair.[2]
- Set any D-brick's key switch to Service.
- Shut IRIX down.
- At the L2 touch display, choose the bricks with DEST, press Power DOWN and confirm.
- Turn off the printer, then the monitors, then other peripherals.
To remove all power, turn off the PDU and PDS breakers, turn off the rear switches of the G-bricks or V-bricks, then unplug the PDU cords and the G-brick or V-brick cords from the wall.[2]
Owner-replaceable parts
[edit | edit source]SGI lists the front panels and L1 display housing, the G-brick L1 controller module and the system disks as owner-replaceable on the Onyx 3000, and puts PCI cards and storage modules in the Origin 3000 owner's guide. XIO cards and V12 boards are for SGI engineers only.[3] Back up the system, log users off and power everything off before starting.[3]
G-brick front panels and L1 module
[edit | edit source]- The upper panel hooks in at the top and is held by two screws near its bottom edge and a guide pin beside the L1 display. It slides over the L1 On/Off button; take care not to break the button.[3]
- The lower panel sits in slots at the bottom and is held by two screws at the top.[3]
- recondas, on the IRIX Network forum, found one more screw holding the upper and lower panels together, behind the magnetic InfiniteReality badge; pull the badge off gently to reach it.[9]
- With the panels off, the L1 display housing bar comes away after four screws, two at each end. Unplug its cable at the controller end, not the display end.[3]
- The L1 module itself is held by four screws, two at the top and two at the bottom, and slides out of the chassis.[3]
Racking a G-brick
[edit | edit source]SGI gave owners no procedure for removing a G-brick from a rack.[9] jwhat, whose G-brick came without a rack, reports that it is held from the back, by a steel shroud on the rear rail of the rack, and slides into the rack from the front on rails.[9] vvuk, who also had one out of a rack, found it heavy at the rear.[9]
The G-brick of jwhat's InfiniteReality4 system came with a Hubbell HBL2621 plug. He fitted an IEC 60309 16 A plug to run it from an Australian 15 A, 240 V outlet, and notes that the colours of the cable inside followed the US convention (green earth, black live, white neutral).[10] Have any plug change checked by a qualified electrician.
Firmware and software
[edit | edit source]- SGI's N-brick addendum calls for IRIX 6.5.13 or later and L1 firmware 1.6.0 or later on every brick before an N-brick is fitted.[11]
- An upgrade to InfiniteReality4 boards needs IRIX 6.5.17 or later.[12]
- sgistuff.net lists IRIX 6.5.15 to 6.5.30 as the releases for the Origin 3000 line and recommends 6.5.30.[8]
- The L1
flash statuscommand shows the two firmware images stored in each L1 and which one is the default.[7]
Monitors
[edit | edit source]The DG5 monitor outputs are 13W3. If a monitor from another system has adjustable RGB inputs, set them to 75 ohms, or the colours will be wrong. Before plugging a monitor into the mains, check that its label matches the outlet voltage.[2] Use setmon to change the video format.[2]
Related pages
[edit | edit source]- SGI Onyx 3000
- SGI Onyx 3000 Troubleshooting Guide
- SGI Onyx 3000 Capacitor Replacement Guide
- SGI Onyx 3000 Documentation
- SGI Origin 3000
- SGI Onyx 350 General Maintenance
References
[edit | edit source]- ↑ 1.0 1.1 1.2 Silicon Graphics, SGI Onyx 3000 Series Graphics System Hardware Owner's Guide, 007-4264-002, November 2001, chapter 1, pp. 1–9 (File:SGI Onyx 3000 Series Graphics System Hardware Owner's Guide (007-4264-002).pdf). Bricks, NUMAlink cables and cable bails (Table 1-1), I-brick battery warning.
- ↑ 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 SGI, 007-4264-002, chapter 4, pp. 92–119. Maintenance and safety, monitor, powering on with the L2 touch display, powering off.
- ↑ 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 SGI, 007-4264-002, chapter 5, pp. 121–125. Customer-replaceable units, safety, G-brick front panels and L1 module.
- ↑ SGI, 007-4264-002, appendix B, pp. 151–154. Lithium battery statement and safety instructions.
- ↑ SGI, 007-4264-002, appendix A, pp. 142–143, Tables A-3 and A-4. Rack and brick weights.
- ↑ SGI, 007-4264-002, chapter 6, pp. 132–133, Table 6-2. L1 temperature messages.
- ↑ 7.0 7.1 7.2 Silicon Graphics, SGI L1 and L2 Controller Software User's Guide, 007-3938-006, chapters 2–3, pp. 45 and 66–90 (File:SGI L1 and L2 Controller Software User's Guide (007-3938-006).pdf).
env,flash,logandpowercommands;pwr uandpwr dabbreviations. - ↑ 8.0 8.1 Gerhard Lenerz, "Origin 3000 / Onyx 3000", sgistuff.net, sgistuff.net (accessed 22 October 2026). Airflow, supported IRIX releases.
- ↑ 9.0 9.1 9.2 9.3 hinnersd, vishnu, jwhat, vvuk and recondas, "Unracking G-Brick", IRIX Network forum, 27–30 October 2021, forums.irixnet.org.
- ↑ John Hartley (jwhat), "SGI Onyx 350 - Racking and Stacking", Just Graphica, 12 July 2021, just.graphica.com.au (accessed 22 October 2026). InfiniteReality4 G-brick power plug and cable.
- ↑ Silicon Graphics, SGI Onyx 3000 N-Brick Addendum, 007-4424-001, p. 1 (File:SGI Onyx 3000 N-Brick Addendum (007-4424-001).pdf).
- ↑ Silicon Graphics, InfiniteReality4 Addendum to Silicon Graphics Onyx2, SGI Onyx 3000 Series, and SGI Onyx 300 Guides, 007-4525-001, 2002, p. 4 (File:SGI InfiniteReality4 Addendum to Onyx2, Onyx 3000 and Onyx 300 Guides (007-4525-001).pdf).