Sanyo MPC-100 Troubleshooting Guide

The Sanyo MPC-100 is Sanyo's British MSX1 computer of 1985.[1] No service manual or circuit diagram for it has been published. The checks below come from Sanyo's operating instructions and from repairs reported on the MSX Resource Center forum.
Sanyo's checklist
[edit | edit source]The operating instructions end with a short checklist for faults that are usually outside the machine.[2]
| Symptom | Check |
|---|---|
| No picture | The power pilot lamp is lit; the television is on; the video or RF lead is connected; a cartridge, if fitted, is seated (remove and refit it); brightness and contrast are set (RF) |
| Poor or weak picture | The television is tuned to the computer's channel; fine tuning (RF); horizontal and vertical hold; the video lead is plugged in |
| Cartridge does not run | The cartridge is locked fully home; its contacts are clean; press the reset button on the right-hand side |
| Computer stops during use | A brief mains interruption; interference from other equipment; printer and recorder connected correctly; an error in the program |
| Cassette load or save fails | The patch cord is connected at both ends; the procedure in section 6 is followed; the recorder's batteries are fresh; tone and volume are set; 2400 baud recordings need a data recorder |
Machine does not power up
[edit | edit source]Start outside the case: the 3 A fuse in the mains plug, the power switch at the rear right, and the power lamp.[3][2]
If those are good, open the case and measure the supply rails at the cartridge slot (see the table below).
Warning: the supply board carries mains voltage. Unplug the machine and let the reservoir capacitor discharge before touching the board.
The faults owners have reported, in the order worth checking, are:
- The glass fuses on the supply board. On one machine both fuses, ET 2A/250V and ET 4A/250V, crackled and dropped out on a continuity test; with new fuses the rails were steady.[4] Fit fuses of the same rating and type.
- The cartridge-slot microswitch. On another machine the supply would not start while its lead to the right-hand side of the main board was connected, and started at once with that lead unplugged and bridged. The fault was the microswitch at the cartridge slot opening, wired to the connector marked MS; cleaning it cured the machine.[5] Bridging the lead is a diagnostic step only. Clean or replace the switch, and do not leave it bypassed.
- The opto-isolator in the supply. The same owner found it broken earlier in that repair; replacing it brought the output up only to about 3 V, because the start circuit was still held off by the microswitch.[5]
The owner of that machine counted two 7812 regulators. A forum member had expected one 7812 for +12 V and one 7912 for −12 V, and later agreed that the MPC-100 has two 7812s.[5] How the −12 V rail is produced has not been published, so measure it at pin 50 of the slot.
Supply rail checks
[edit | edit source]Measure with the machine switched on and no cartridge fitted, against pin 41 or 43 of the cartridge slot.[6]
| Point | Signal | If it is missing |
|---|---|---|
| Slot pins 45 and 47 | +5 V | Nothing runs: check the fuses, the microswitch circuit and the harness to the main board |
| Slot pin 48 | +12 V | Check the 7812 regulators and their input |
| Slot pin 50 | −12 V | Check the negative supply; the circuit is unpublished |
| Joystick pin 5 | +5 V | As for slot pins 45 and 47 |
Sanyo published no tolerances for these rails.
No picture or a poor picture
[edit | edit source]- Go through Sanyo's checklist above first.[2]
- The RF output is on UHF channel 36 (591.25 MHz); tune the television there.[7]
- Try the composite video output to rule out the RF modulator.[7]
- With a good picture on composite but none on RF, look at the RF modulator and its lead.
- A picture in black and white on both outputs: the MPC-100 produces PAL colour, which a monitor made for NTSC regions cannot decode.[8] One owner whose monitors were PAL reported the same symptom, and no cause was found in that thread.
No sound
[edit | edit source]Compare the phono audio output with the sound on the RF output. On one machine the phono output worked and the RF sound had been turned down on one of the three presets on the board; a quarter turn brought it back.[4] The same owner tried the AY-3-8910 in a Philips VG-8020 and it worked, and a forum reply noted that a dead PSG chip is rare.[4] Check the +12 V rail, the presets and the output sockets before changing the sound chip.
Cassette faults
[edit | edit source]Work through Sanyo's checks first: the patch cord, the procedure, the recorder's batteries, tone and volume, and the 2400 baud limit.[2] The remote contacts are pins 6 (REM+) and 7 (REM−) of the cassette socket; output is pin 4 and input pin 5.[9]
One owner's recorder motor would not start under LOAD with the remote lead connected, and the machine would not load or save even with the motor running. MOTOR ON and MOTOR OFF in BASIC gave no relay click. Forum members placed the relay near the power connector on the main board and suggested checking its coil, and the ground pins of the cassette socket. The thread ended without a reported fix.[10] A relay that does not click and a load that fails with the motor running are two faults: check the relay coil and its driver for the first, and the socket's ground pins and the input on pin 5 for the second.
Cartridge and expansion bus faults
[edit | edit source]- Seat the cartridge with its hole to the left and push it down until it clicks.[11]
- Clean the cartridge contacts and press the reset button on the right-hand side.[2]
- The rear expansion bus has the same signals as the slot.[6] A cartridge that runs through an adapter there but not in the top slot points to the top slot or its contacts.
Related pages
[edit | edit source]- Sanyo MPC-100
- Sanyo MPC-100 General Maintenance
- Sanyo MPC-100 Capacitor Replacement Guide
- Sanyo MPC-100 Operating Instructions
- Capacitor Failure Symptoms
References
[edit | edit source]- ↑ Sanyo MPC-100, MSX Resource Center wiki—link(accessed 2026-10-21) Community specification page: British adaptation of the MPC-6, 1985; NEC D780C-1, TMS9929ANL, AY-3-8910, 64 KB RAM; one cartridge slot and a rear expansion bus.
- ↑ 2.0 2.1 2.2 2.3 2.4 Sanyo, MSX Personal Computer Operating Instructions (MPC-100), pages 29 and 30, "Troubleshooting". Hosted here as Sanyo MPC-100 Operating Instructions.
- ↑ Sanyo, MSX Personal Computer Operating Instructions (MPC-100), cover, "Important notice": a 3 A fuse with a 13 A (BS 1363) plug; the apparatus must be earthed. See Sanyo MPC-100 Operating Instructions.
- ↑ 4.0 4.1 4.2 MPC-100 no sound, February 2017—link(accessed 2026-10-21) Owner's report: the two fuses in the power supply, ET 2A/250V and ET 4A/250V, gave a crackling, intermittent result on a continuity test and were replaced, after which the voltages were steady; the AY-3-8910 worked in a Philips VG-8020; sound was present at the phono audio output; a quarter turn of one of three preset potentiometers restored the RF sound. A reply from RetroTechie: check the rails first; a dead PSG chip is rare; compare the RF and phono outputs.
- ↑ 5.0 5.1 5.2 Sanyo MPC-100 power supply dead, July to September 2013—link(accessed 2026-10-21) Owner's report: no output; transistor Q2 (marked D1571) suspected, with over 140 V AC measured on its heatsink; a broken opto-isolator replaced, after which the output was about 3 V; two 7812 regulators found where a reply expected a 7812 and a 7912; the supply then shown to work but not to start while connected to the main board; with the lead unplugged and bridged the machine started; a reply pointed to the connector marked MS and the microswitch at the slot opening; cleaning the microswitch fixed it. A later reply confirmed two 7812s in the MPC-100.
- ↑ 6.0 6.1 Sanyo, MSX Personal Computer Operating Instructions (MPC-100), page 33, "ROM Cartridge Slot/Expansion Bus": pins 41 and 43 GND, 45 and 47 +5 V, 48 +12 V, 50 −12 V; page 32, joystick terminal pin 5 +5 V, pin 9 GND. See Sanyo MPC-100 Operating Instructions.
- ↑ 7.0 7.1 Sanyo, MSX Personal Computer Operating Instructions (MPC-100), page 31, "Specification": video 1.0 V p-p, 75 Ω, phono; audio 1.26 V p-p, 600 Ω, phono; RF UHF channel 36 (591.25 MHz). See Sanyo MPC-100 Operating Instructions.
- ↑ SANYO MPC-100 black & white video out error, January 2024—link(accessed 2026-10-21) Owner's report of black-and-white composite and RF output from an MPC-100; a reply explained that NTSC monitors cannot decode the MPC-100's PAL colour signal; the owner said his monitors were PAL, and no fix was reported.
- ↑ Sanyo, MSX Personal Computer Operating Instructions (MPC-100), page 32, "Cassette Tape Recorder Terminal": pins 1, 2, 3 and 8 GND, 4 CMTOUT, 5 CMTIN, 6 REM+, 7 REM−. See Sanyo MPC-100 Operating Instructions.
- ↑ Sanyo MPC-100 Tape recorder problem, June 2016—link(accessed 2026-10-21) Owner's report and replies: no motor start on LOAD or BLOAD with the remote lead in; no loading or saving with three recorders that worked on a Philips VG-8020; no relay click with MOTOR ON and MOTOR OFF; about 0.13 V on the remote pins with MOTOR ON; replies placed the relay near the power connector on the main board and suggested checking the coil and the connector's ground pins.
- ↑ Sanyo, MSX Personal Computer Operating Instructions (MPC-100), page 10, "Loading ROM Cartridge": keep the cartridge hole to the left and push the cartridge down until it clicks; an improper contact may damage the computer. See Sanyo MPC-100 Operating Instructions.